Onur Ozturk

Mr. Onur Ozturk

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2022 in Journal of Cleaner Production
Verified
Journal Article
Closed access
OOOnur Ozturk
Onur Ozturk
NONILUFER OZYURT
NILUFER OZYURT

24 June 2025 in Materials and Structures
Verified
Journal Article
Open access
PDF file
VMViktor Mechtcherine
Viktor Mechtcherine
SMShravan Muthukrishnan
Shravan Muthukrishnan
ARAnnika Robens-Radermacher
Annika Robens-Radermacher
RWRob Wolfs
Rob Wolfs
JVJelle Versteege
Jelle Versteege
FBFreek Bos
Freek Bos
Traditional construction techniques, such as in-situ casting and pre-cast concrete methods, have well-established testing protocols for assessing compressive strength and modulus of elasticity, including specific procedures for sample preparation and curing. In contrast, 3D concrete printing currently lacks standardized testing protocols, potentially contributing to the inconsistent results reported in previous studies. To address this issue, RILEM TC 304-ADC initiated a comprehensive interlaboratory study on the mechanical properties of 3D printed concrete. This study involves 30 laboratories worldwide, contributing 34 sets of data, with some laboratories testing more than one mix design. The compressive strength and modulus of elasticity were determined under three distinct conditions: Default, where each laboratory printed according to their standard procedure followed by water bath curing; Deviation 1, which involved creating a cold joint by increasing the time interval between printing layers; and Deviation 2, where the standard printing process was used, but the specimens were cured under conditions different from water bath. Some tests were conducted at two different scales based on specimen size—“mortar-scale” and “concrete-scale”—to investigate the size effect on compressive strength. Since the mix design remained identical for both scales, the only variable was the specimen size. This paper reports on the findings from the interlaboratory study, followed by a detailed investigation into the influencing parameters such as extraction location, cold joints, number of interlayers, and curing conditions on the mechanical properties of the printed concrete. As this study includes results from laboratories worldwide, its contribution to the development of relevant standardized testing protocols is critical.

24 June 2025 in Materials and Structures
Verified
Journal Article
Open access
PDF file
RWRob Wolfs
Rob Wolfs
JVJelle Versteege
Jelle Versteege
MSManu Santhanam
Manu Santhanam
SBShantanu Bhattacherjee
Shantanu Bhattacherjee
FBFreek Bos
Freek Bos
VMViktor Mechtcherine
Viktor Mechtcherine
This paper discusses the flexural and tensile strength properties of 3D printed concrete, based on the results of a RILEM TC 304-ADC interlaboratory study on mechanical properties. These properties are determined using different testing techniques, including 3- and 4-point flexural tests, splitting tests, and uniaxial tension tests, on specimens extracted from large 3D printed elements in accordance with a prescribed study plan. The relationship between compressive and flexural or tensile strengths, cast or printed samples, different types of tests, and different loading orientations, are analysed to understand the influence of 3D printing. As expected, the strength can reduce significantly when the main tensile stress is acting perpendicular to the interface between layers. The role of deviations from the standard study procedure, in terms of the time interval between the placing of subsequent layers, or the adoption of a different curing strategy, are also assessed. While the increased time interval significantly impacts the strength in the critical direction, the use of variable curing conditions does not seem to have a clear-cut effect on the strength ratios of the printed to cast specimens. Additionally, the paper looks at the variability in the results for the printed specimens, in order to emphasize the need for multiple replicates for obtaining a proper result. An extensive insight into the aspects affecting the variability is presented in the paper. Finally, with the limited dataset available for specimens tested at a larger scale, it is difficult to arrive at a clear understanding of the role of specimen size (i.e., greater number of layers).

28 September 2020 in International Journal of Pavement Engineering
Verified
Journal Article
Closed access
YAYavuz Abut
Yavuz Abut
SYSalih Taner YILDIRIM
Salih Taner YILDIRIM
OOOnur Ozturk
Onur Ozturk
NONILUFER OZYURT
NILUFER OZYURT
Due to its superior properties, usage of Roller Compacted Concrete (RCC) in pavement applications gradually increases. As the compaction effort and curing conditions applied are significantly altered between laboratory and field conditions, performance of RCC may be considerably different. Therefore, studies that are carried out to compare the laboratory and field RCC performance have crucial importance. On the other hand, number of these studies are very limited. In the presented study, a RCC mixture was designed and applied to a site in Kocaeli/Turkey. Required pavement thickness was determined based on AASHTO (1993) design methodology, and performance of laboratory and field RCC (in terms of compressive strength, splitting tensile strength, ultrasonic pulse velocity (UPV), capillarity, abrasion resistance, density, water absorption and porosity) were determined and compared. As a result of the study for almost all of the performance parameters decreased values were obtained for RCC when compared to laboratory specimens. This result was attributed to difference between field and laboratory compaction effort and curing conditions.

28 August 2025 in Cement and Concrete Composites
Verified
Journal Article
Closed access
OOOnur Ozturk
Onur Ozturk
CLCaleb Lunsford
Caleb Lunsford
JSJames Strait
James Strait
SNSriramya D. Nair
Sriramya D. Nair

28 February 2022 in International Journal of Pavement Engineering
Verified
Journal Article
Closed access
OOOnur Ozturk
Onur Ozturk
HYHasan Yildirim
Hasan Yildirim
NONILUFER OZYURT
NILUFER OZYURT
TOTuran Ozturan
Turan Ozturan
Due to the large-scale use of materials in highways, the sustainability of materials has attracted considerable interest for years. In this respect, significant effort has been spent investigating the use of recycled aggregates in concrete pavements. This study has been carried out to fill the gap in the structural performance of recycled aggregate concrete pavements. First, properties of concrete mixtures, produced with virgin, recycled concrete and recycled brick aggregates were experimentally measured, and the results were compared. Then, finite element analyses were done by following a novel methodology that considers the well-known previous works. Results showed that replacement of coarse aggregates with recycled aggregates decreases the mechanical properties in various amounts. Due to the resulting performances, for the same slab thickness, decreased maximum stress, increased deflection and stress ratio values were found for recycled aggregate mixtures. Additionally, higher thicknesses and material requirements were found for recycled aggregate concrete for a similar life. Despite the decreased performance and increased material requirements, the use of recycled aggregates in pavements can still be a viable alternative for countries with limited natural resources and landfills. Therefore, based on the findings, several important discussions and suggestions were presented for future works.