As a critical factor in the built environment, lighting presents considerable influence on occupants. Previous research across static lighting conditions has found that both illuminance and correlated color temperature (CCT) affect occupants’ physiological and psychological functioning. However, little research has been conducted on the non-visual impacts of dynamic lighting with daily variation in illuminance and CCT levels. The purpose of this study is to better understand the impact of dynamic lighting on office occupants’ health, well-being and experience at a living lab. Fifteen participants were recruited to work in three office modules for four months. Four lighting conditions were designed and implemented in this study, including two static lighting conditions and two dynamic lighting conditions with a specific predefined control scheme. A prototype lighting system with enhanced control capabilities was configured and implemented to ensure the desired lighting environment protocol. Both objective methods and subjective surveys were used to assess the behavioral and physiological outcomes of interest, including mental stress, sleep, productivity, satisfaction, mood, visual comfort and perceived naturalness. The results showed that the daytime behavioral impacts were either positive or mixed. Specifically, a significant alertness increase was observed in the afternoon, indicating a potential solution to reduce the natural feelings of sleepiness during the workday. There was also a marginal benefit for mood. The nighttime impacts include a significant decrease in perceived sleep quality and sleep time after subjects were exposed to dynamic lighting. No significant differences were observed for mental stress, productivity, visual comfort, or perceived naturalness. The findings present additional insights into the non-visual impacts of dynamic lighting and give recommendations for further investigations.
Engineering technology plays a pivotal role in the delivery of health care in under-resourced countries by providing an infrastructure to improve patient outcomes. However, sustainability of these technologies is difficult in these settings oftentimes due to limited resources or training. The framework presented in this editorial focuses on establishing medical and laboratory equipment sustainability in developing countries and is comprised of four steps: 1) establishing reliable in-country relationships with stakeholders, 2) identifying needs for sustainable solutions locally, 3) exploring potential solutions and assessing their effort-to-impact ratios, and 4) working with strategic partners to implement solutions with clear performance metrics. By focusing on the sustainability of donated equipment instead of the equipment itself, this method presented distinguishes itself from other philanthropic endeavors in the field by seeking to establish preventive maintenance habits that can impact clinical outcomes of a community long term. Application of this methodology is reported in the Original Research Article "A Low-Cost Humidity Control System to Protect Microscopes in a Tropical Climate" by Asp et. al.
Previous work has demonstrated the modest impact of environmental interventions that manipulate lighting, sound, or temperature on sleep inertia symptoms. The current study sought to expand on previous work and measure the impact of a multimodal intervention that collectively manipulated light, sound, and ambient temperature on sleep inertia. Participants slept in the lab for four nights and were awoken each morning by either a traditional alarm clock or the multimodal intervention. Feelings of sleep inertia were measured each morning through Psychomotor Vigilance Test (PVT) assessments and ratings of sleepiness and mood at five time-points. While there was little overall impact of the intervention, the participant’s chronotype and the length of the lighting exposure on intervention mornings both influenced sleep inertia symptoms. Moderate evening types who received a shorter lighting exposure (≤15 min) demonstrated more lapses relative to the control condition, whereas intermediate types exhibited a better response speed and fewer lapses. Conversely, moderate evening types who experienced a longer light exposure (>15 min) during the intervention exhibited fewer false alarms over time. The results suggest that the length of the environmental intervention may play a role in mitigating feelings of sleep inertia, particularly for groups who might exhibit stronger feelings of sleep inertia, including evening types.
Household air pollution (HAP), particularly from cooking-related particulate matter (PM 2.5 ), poses significant health risks but remains understudied compared to ambient air pollution. We evaluated the short-term cardiorespiratory effects of exposure to cooking-generated PM 2.5 and examined the efficacy of automated indoor air quality interventions. Using a crossover design, seven cohorts of two participants each were exposed to two residential conditions over four weeks in a Living Lab: the Standard Control Condition (SCC), featuring basic HVAC, and the Advanced Control Condition (ACC), which included automated range hoods, portable air cleaners and exhaust systems activated by PM 2.5 sensors. PM 2.5 concentrations were continuously monitored in the breathing zone at the room level. The physiological markers, blood pressure (BP), heart rate (HR), heart rate variability (HRV) and fractional exhaled nitric oxide (FeNO), were measured on the occupant before and after cooking events. Cooking events caused substantial short-term increases in PM 2.5 levels, median concentrations rose from < 1 µg/m³ to 263.7 µg/m³ under SCC and to 168.9 µg/m³ under ACC during HRV measurement periods, with exposure levels exceeding WHO 24-hour guidelines up to 82% of the time. Compared to SCC, the ACC significantly reduced PM 2.5 exposure ( p < 0.05). Systolic blood pressure (SBP) decreased significantly post-cooking under ACC (ΔSBP = −3.1 ± 10.0 mmHg) but not in the SCC (ΔSBP = −0.9 ± 8.0 mmHg; p < 0.05). HR and HRV showed no statistically significant differences between conditions, though trends in RMSSD, SDNN and LF/HF ratio suggested improved autonomic balance under ACC. HR decreased post-cooking under ACC but increased slightly under SCC (ΔHR = −4.5 ± 6.5 bpm vs. 1.0 ± 1.1 bpm; 95% CI: (−9.8 to −1.2)). FeNO decreased significantly within both conditions pre- to post-cooking, but the difference in reduction between conditions did not reach statistical significance, despite a trend toward greater decline in the ACC. These findings suggest that semi-chronic exposure to cooking-related PM 2.5 can adversely affect cardiovascular function, particularly systolic BP and HR, and that automated indoor air quality interventions can meaningfully reduce pollutant exposure and associated physiological impacts. Our results support the implementation of HAP mitigation strategies in residential settings and highlight the need for further research among populations with existing cardiopulmonary conditions.