Sing-Sin Sam

Dr. Sing-Sin Sam

University of Malaya, Kuala Lumpur, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2013 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
BTBoon-Teong Teoh
Boon-Teong Teoh
SSSing-Sin Sam
Sing-Sin Sam
Kim Kee TanKim Kee Tan
Kim Kee Tan
JJJefree Johari
Jefree Johari
MDMohammed Bashar Danlami
Mohammed Bashar Danlami
SASAZALY ABUBAKAR
SAZALY ABUBAKAR
Background: Early and rapid detection of dengue virus (DENV) infection during the febrile period is crucial for proper patient management and prevention of disease spread. An easy to perform and highly sensitive method is needed for routine implementation especially in the resource-limited rural healthcare settings where dengue is endemic.Methods: A single-tube reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay with a set of nine primers was developed for the detection of all four DENV serotypes and their different genotypes. The sensitivity and specificity of the RT-LAMP were evaluated. The clinical applicability of RT-LAMP assay for detection of DENV RNA was assessed in a total of 305 sera of clinically-suspected dengue patients. The test results of RT-LAMP were statistically compared to those of quantitative reverse transcription-polymerase chain reaction (qRT-PCR), IgM- and IgG-capture enzyme-linked immunosorbent assays (ELISA).Results: Acute DENV infection was confirmed in 171 samples (n = 305); 43.3% (74/171) and 46.8% (80/171) of the samples were positive for DENV using RT-LAMP and qRT-PCR, respectively. The combination of RT-LAMP with the dengue IgM and IgG ELISA increased detection of acute DENV infection to 97.7% (167/171), in comparison to only 70.8% (121/171) when dengue IgM and IgG ELISA alone were used. The RT-LAMP assays showed high concordance (κ = 0.939) with the qRT-PCR. The RT-LAMP assay detected up to 10 copies of virus RNA within an hour but 100% reproducibility (12/12) was achieved with 100 copies. There was no cross reactivity of RT-LAMP with other closely related arboviruses.Conclusion: The RT-LAMP assay developed in this study is sensitive, specific and simple to perform. The assay improved the detection of dengue when used in combination with serological methods.

28 September 2013 in BMC Ecology and Evolution
Verified
Journal Article
Open access
PDF file
BTBoon-Teong Teoh
Boon-Teong Teoh
SSSing-Sin Sam
Sing-Sin Sam
Kim Kee TanKim Kee Tan
Kim Kee Tan
JJJefree Johari
Jefree Johari
MSMeng-Hooi Shu
Meng-Hooi Shu
SASAZALY ABUBAKAR
SAZALY ABUBAKAR
Background: Recurring dengue outbreaks occur in cyclical pattern in most endemic countries. The recurrences of dengue virus (DENV) infection predispose the population to increased risk of contracting the severe forms of dengue. Understanding the DENV evolutionary mechanism underlying the recurring dengue outbreaks has important implications for epidemic prediction and disease control.Results: We used a set of viral envelope (E) gene to reconstruct the phylogeny of DENV-1 isolated between the periods of 1987–2011 in Malaysia. Phylogenetic analysis of DENV-1 E gene revealed that genotype I virus clade replacements were associated with the cyclical pattern of major DENV-1 outbreaks in Malaysia. A total of 9 non-conservative amino acid substitutions in the DENV-1 E gene consensus were identified; 4 in domain I, 3 in domain II and 2 in domain III. Selection pressure analyses did not reveal any positively selected codon site within the full length E gene sequences (1485 nt, 495 codons). A total of 183 (mean dN/dS= 0.0413) negatively selected sites were found within the Malaysian isolates; neither positive nor negative selection was noted for the remaining 312 codons. All the viruses were cross-neutralized by the respective patient sera suggesting no strong support for immunological advantage of any of the amino acid substitutions.Conclusion: DENV-1 clade replacement is associated with recurrences of major DENV-1 outbreaks in Malaysia. Our findings are consistent with those of other studies that the DENV-1 clade replacement is a stochastic event independent of positive selection.

11 April 2018 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
Kim Kee TanKim Kee Tan
Kim Kee Tan
NANoor Syahida Azizan
Noor Syahida Azizan
CYChe Norainon Yaacob
Che Norainon Yaacob
NSNurul Asma Anati Che Mat Seri
Nurul Asma Anati Che Mat Seri
NSNur Izyan Samsudin
Nur Izyan Samsudin
SASAZALY ABUBAKAR
SAZALY ABUBAKAR
A method for rapid detection of dengue virus using the reverse-transcription recombinase polymerase amplification (RT-RPA) was recently developed, evaluated and made ready for deployment. However, reliance solely on the evaluation performed by experienced researchers in a well-structured and well-equipped reference laboratory may overlook the potential intrinsic problems that may arise during deployment of the assay into new application sites, especially for users unfamiliar with the test. Appropriate assessment of this newly developed assay by users who are unfamiliar with the assay is, therefore, vital. An operational utility test to elucidate the efficiency and effectiveness of the dengue RT-RPA assay was conducted among a group of researchers new to the assay. Nineteen volunteer researchers with different research experience were recruited. The participants performed the RT-RPA assay and interpreted the test results according to the protocol provided. Deviation from the protocol was identified and tabulated by trained facilitators. Post-test questionnaires were conducted to determine the user satisfaction and acceptability of the dengue RT-RPA assay. All the participants completed the test and successfully interpreted the results according to the provided instructions, regardless of their research experience. Of the 19 participants, three (15.8%) performed the assay with no deviations and 16 (84.2%) performed the assay with only 1 to 5 deviations. The number of deviations from protocol, however, was not correlated with the user laboratory experience. The accuracy of the results was also not affected by user laboratory experience. The concordance of the assay results against that of the expected was at 89.3%. The user satisfaction towards the RT-RPA protocol and interpretation of results was 90% and 100%, respectively. The dengue RT-RPA assay can be successfully performed by simply following the provided written instructions. Deviations from the written protocols did not adversely affect the outcome of the assay. These suggest that the RT-RPA assay is indeed a simple, robust and efficient laboratory method for detection of dengue virus. Furthermore, high new user acceptance of the RT-RPA assay suggests that this assay could be successfully deployed into new laboratories where RT-RPA was not previously performed.

30 April 2022 in Viruses
Verified
Journal Article
Open access
PDF file
NMNoor-Adila Mohamed-Romai-Noor
Noor-Adila Mohamed-Romai-Noor
SSSing-Sin Sam
Sing-Sin Sam
BTBoon-Teong Teoh
Boon-Teong Teoh
ZHZur-Raiha Hamim
Zur-Raiha Hamim
SASAZALY ABUBAKAR
SAZALY ABUBAKAR
Getah virus is an emerging mosquito-borne animal pathogen. Four phylogenetic groups of GETV, Group I (GI), GII, GIII and GIV, were identified. However, only the GETV GIII was associated with disease epidemics suggesting possible virulence difference in this virus group. Here, we compared the genetic and in vitro phenotypic characteristics between the epidemic and non-epidemic GETV. Our complete coding genome sequence analyses revealed several amino acid substitutions unique to the GETV GIII and GIV groups, which were found mainly in the hypervariable domain of nsP3 and E2 proteins. Replication kinetics of the epidemic (GIII MI-110 and GIII 14-I-605) and non-epidemic GETV strains (prototype GI MM2021 and GIV B254) were compared in mammalian Vero cells and mosquito C6/36 and U4.4 cells. In all cells used, both epidemic GETV GIII MI-110 and GIII 14-I-605 strains showed replication rates and mean maximum titers at least 2.7-fold and 2.3-fold higher than those of GIV B254, respectively (Bonferroni posttest, p < 0.01). In Vero cells, the epidemic GETV strains caused more pronounced cytopathic effects in comparison to the GIV B254. Our findings suggest that higher virus replication competency that produces higher virus titers during infection may be the main determinant of virulence and epidemic potential of GETV.

25 November 2022 in Immuno
Verified
Journal Article
Open access
PDF file
RLRafidah Lani
Rafidah Lani
BTBoon-Teong Teoh
Boon-Teong Teoh
SSSing-Sin Sam
Sing-Sin Sam
SASAZALY ABUBAKAR
SAZALY ABUBAKAR
Pouya HassandarvishPouya Hassandarvish
Pouya Hassandarvish
In the chronic phase of chikungunya virus (CHIKV) infection, excessive inflammation manifests as incapacitating joint pain and prolonged arthritis. Arthritis resulted from a large influx of infiltrating immune cells driven by pro-inflammatory cytokines and chemokines originating from the toll-like receptor (TLR)-mediated innate antiviral response. This study investigated fisetin’s ability to modulate TLR-mediated antiviral responses against CHIKV in Huh7 cells. The CHIKV inhibitory potential of fisetin was assessed by plaque-forming unit assay, virus yield reduction assay, and bright-field microscopy (cytopathic effect, immunofluorescence). Fisetin’s modulatory potential on TLR-mediated antiviral response was evaluated by immunofluorescence assay (expression of TLR proteins), qRT-PCR (mRNA level of antiviral genes), human cytokine array, and the immunoblotting of key transcription factors. The present study showed fisetin induced the expression of the antiviral genes at an early time-point by promoting the phosphorylation of IRF3 and IRF7. Fisetin reduced excessive inflammatory cytokine responses in CHIKV-infected Huh7 cells by impeding the over-phosphorylation of NF-κB. Fisetin also reduced CHIKV-induced cytopathic effects in CHIKV-infected Huh7 cells. Altogether, our study suggests that fisetin modulates TLR-mediated antiviral responses by affecting the CHIKV-induced inflammatory responses.

30 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
HMHinata Maeno
Hinata Maeno
PWPooi-Fong Wong
Pooi-Fong Wong
SASAZALY ABUBAKAR
SAZALY ABUBAKAR
MYMing Yang
Ming Yang
SSSing-Sin Sam
Sing-Sin Sam
AJAnilawati Mat Jelani
Anilawati Mat Jelani
Serum is commonly used as a specimen in immunoassays but the presence of heterophilic antibodies can potentially interfere with the test results. Previously, we have developed a microfluidic device called: 3D Stack for enzyme-linked immunosorbent assay (ELISA). However, its evaluation was limited to detection from a single protein solution. Here, we investigated the sensitivity of the 3D Stack in detecting a severe dengue biomarker—soluble CD163 (sCD163)—within the serum matrix. To determine potential interactions with serum matrix, a spike-and-recovery assay was performed, using 3D Stacks with and without surface modification by an EDC–NHS (N-ethyl-N′-(3-(dimethylamino)propyl)carbodiimide/N-hydroxysuccinimide) coupling. Without surface modification, a reduced analyte recovery in proportion to serum concentration was observed because of the Vroman effect, which resulted in competitive displacement of coated capture antibodies by serum proteins with stronger binding affinities. However, EDC–NHS coupling prevented antibody desorption and improved the sensitivity. Subsequent comparison of sCD163 detection using a 3D Stack with EDC–NHS coupling and conventional ELISA in dengue patients’ sera revealed a high correlation (R = 0.9298, p < 0.0001) between the two detection platforms. Bland–Altman analysis further revealed insignificant systematic error between the mean differences of the two methods. These data suggest the potentials of the 3D Stack for further development as a detection platform.