Negar Heidari Heidari Matin

Dr. Negar Heidari Heidari Matin

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
ZRZhina Rashidzadeh
Zhina Rashidzadeh
Negar Heidari Heidari MatinNegar Heidari Heidari Matin
Negar Heidari Heidari Matin
A facade can control interaction between the building and the environment. Advancements in control technologies and material science give the opportunity of using smart windows in a high-performance facade to improve the building’s energy performance and users’ comfort. This study aims to propose practical recommendations for smart windows’ implementation over various climate zones across the world. To follow this aim, 54 studies published from 2013 to 2022 collected from architecture, engineering, and material science databases and have been reviewed, and seven types of smart windows including electrochromic, photovoltachromic, gasochromic, thermochromic, photochromic, hydrochromic, and Low-E have been identified. Moreover, the thermal properties and visual features of smart coatings used in the windows and their impacts on energy efficiency and users’ comfort were recognized. Then, a comparative study was conducted to identify and propose the most efficient coating utilized in the structure of smart windows across different climate zones.

28 February 2021 in Intelligent Buildings International
Verified
Journal Article
Closed access
Negar Heidari Heidari MatinNegar Heidari Heidari Matin
Negar Heidari Heidari Matin
AEAli Eydgahi
Ali Eydgahi
This study presents a data-driven approach for investigating practical aspects of responsive facades illuminance optimization. In this approach, the hourly indoor illuminance data and spatial information are integrated to form an objective function. Then, the objective function is used to assess the visual performance of responsive facade systems by matching a wide range of angle movements with hourly daylight patterns. An office room with a responsive facade was simulated parametrically to test the proposed optimization function through design scenarios. Raw indoor illuminance data was generated for a year of both horizontal and vertical facade configurations in four different facade orientations and four facade locations/climate zones. Data analytic techniques were deployed for quality assurance, pre-processing, managing and analyzing the simulated data. A Brute-force search algorithm was utilized to determine the hourly optimum angle of the facade configuration. The result reveals hourly optimum adaptation angles can significantly improve indoor illuminance of all possible scenarios such as various facade configurations, facade orientations, and facade locations/climate zones in comparison with no-louvers and fixed louvers scenarios.

20 June 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Negar Heidari Heidari MatinNegar Heidari Heidari Matin
Negar Heidari Heidari Matin
Ali EydgahiAli Eydgahi
Ali Eydgahi
Payam MatinPayam Matin
Payam Matin
The photochromic coating is a promising smart technology that provides different optical properties in response to daylight variations. The application of photochromic coatings with various colors/shades on window glass is one of the current research approaches for finding better energy saving techniques. The aim of this study was to develop a series of photochromic coatings for window glass and measure the impact of such smart technologies on occupants’ visual comfort. This paper examines the visual performance of building facades that utilize windows with different photochromic-coated glass. The visual performance data of three window types coated with nine different photochromic color shades were considered and compared to determine the best photochromic shades and window types that provide optimum visual metrics for the inside of the building. The results show that compared to no-coating glass, both the Daylight Glare Probability and the Useful Daylight Illuminance could be improved by using multi-color coatings that contain equal or different color proportions for photochromic window glass. From an energy-saving point of view, the results indicate that the windows coated with photochromic materials provide a better alternative to the no-coating window products.

20 January 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
Negar Heidari Heidari MatinNegar Heidari Heidari Matin
Negar Heidari Heidari Matin
Ali EydgahiAli Eydgahi
Ali Eydgahi
AGAmin Gharipour
Amin Gharipour
Ensuring visual comfort for occupants in sustainable buildings involves addressing discomfort glare and its associated risks. Responsive facades, designed based on pre-set algorithms, enhance visual performance and reduce discomfort glare by continuously adapting to changes in daylight intensity, reflection, or color. In this study, computational models were developed by incorporating hourly daylight glare probability (DGP) with occupants’ spatial data and facade active variables to minimize discomfort glare for responsive facades. To evaluate these models, a room with an office setting was parametrically simulated with a responsive facade, generating hourly DGP data for an entire year across different facade configurations, building orientations, and climate zones. The Exhaustive Search Algorithm was then used to calculate the optimal hourly angles for the facade configurations. The results indicate that the proposed models can significantly maintain DGPs within an imperceptible range (<0.35) in all scenarios compared to a no-louver scenario. These models offer valuable insights for architects, facade designers, and researchers aiming to enhance occupant visual comfort and productivity through innovative responsive facade strategies. Aligning visual comfort, well-being, and productivity with sustainability ensures that buildings operate efficiently while providing a healthy and comfortable environment for users.

22 June 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Negar Heidari Heidari MatinNegar Heidari Heidari Matin
Negar Heidari Heidari Matin
Ali EydgahiAli Eydgahi
Ali Eydgahi
AGAmin Gharipour
Amin Gharipour
Payam MatinPayam Matin
Payam Matin
The associations between various design variables affecting the visual performance of responsive facade systems are investigated in this study. First, we propose a data-driven approach to study practical aspects of illuminance optimization for responsive facades. In this approach, the hourly indoor illuminance data are combined with the location information to generate an objective function. This function is then utilized to evaluate the visual performance of responsive facade systems by matching a variety of facade angle movements to hourly sunshine patterns. Next, statistical tests were deployed to evaluate the role of design variables in different scenarios. The results provide detailed information about the design variables and their effects on visual comfort at 0.05 significant levels. On average, facade angles, facade configurations, facade orientations, and facade locations were significant in 100%, 41%, 87%, and 45% of different possible combinations of scenarios/variables, respectively.

24 December 2021
Verified
Conference Paper
Closed access
Negar Heidari Heidari MatinNegar Heidari Heidari Matin
Negar Heidari Heidari Matin
Ali EydgahiAli Eydgahi
Ali Eydgahi
A building envelope and its performance evaluation utilizing various smart coated window glass panes that turn to different colors/shades according to the intensity of the exposed solar radiation is presented. The results show the application of a multi-color photochromic window-pane with the same and various color proportions improve the Daylight Glare Probability by 54 and 60% and the Useful Daylight Illuminance by 36 and 37% compared to blank glass, respectively.