1 January 2013 in International Journal of Energy and Environmental Engineering
Verified
Journal Article
Open access
PDF file
AAAmr Sayed Hassan Abdallah
Amr Sayed Hassan Abdallah
HYHiroshi Yoshino
Hiroshi Yoshino
TGTomonobu Goto
Tomonobu Goto
NENapoleon Enteria
Napoleon Enteria
MRMagdy M Radwan
Magdy M Radwan
MEM Eid
M Eid
Cooling buildings in summer is one of the main environmental problems for architects and occupants in many hot dry countries. The summer temperature during these countries reaches peaks of more than 40°C in some. Mechanical air conditioners can solve the problem, but they put a heavy strain on the electricity consumption. Egypt in general has rich sunny and clear skies. Therefore, these conditions encourage to enhance evaporating with natural ventilation and save energy. This paper develops an integration of direct evaporative cooling tower with a solar chimney multi-zone thermal ventilation model. Simulation is done using commercial couple multi-zone airflow under COMIS-TRNSYS software (Madison, WI, USA) to assess natural ventilation and indoor thermal comfort. The results show that the system generates 130.5 m3/h under the effect of solar radiation only and minimum 2 ACH without pressure coefficient which is considered the minimum requirement of ACH. The findings show that the new integrated system interacts with the building envelope and weather conditions to achieve a decrease in indoor temperatures that reach 10°C to 11.5°C compared to outdoor temperatures.

1 April 2014 in International Journal of Energy and Environmental Engineering
Verified
Journal Article
Open access
PDF file
AAAmr Sayed Hassan Abdallah
Amr Sayed Hassan Abdallah
YHYoshino Hiroshi
Yoshino Hiroshi
TGTomonobu Goto
Tomonobu Goto
NENapoleon Enteria
Napoleon Enteria
MRMagdy M. Radwan
Magdy M. Radwan
MEM. Abdelsamei Eid
M. Abdelsamei Eid
Houses in Egypt are often designed without taking the climate into account sufficiently. Consequently, new houses often have a poor indoor climate, which affects comfort, health and building efficiency. In hot and arid climates, passive cooling system employs non-mechanical procedures to maintain suitable indoor temperature. Thus, they have been increasing the influence of the traditional cooling concepts but with new technology. Therefore, these conditions encourage such a concept to enhance natural ventilation with evaporative cooling and save energy in the New Assiut city. In the present study, the effect of solar chimney parameters on wind tower parameters was numerically investigated as a second phase of the new integrated model. All the detailed mathematical equations and system description are presented in phase one. A numerical simulation is implemented in Transient systems simulation program-Conjunction of multizone infiltration specialists program softwares. The parametric studies of the integrated system in phase two were studied to achieve high performance with new compact small design especially for the hottest days in the summer season. The temperature and airflow rates are predicted iteratively taking into account the zone pressure and the pressure drop in the evaporative cooler component. The result shows that the system achieves nearly at least close to 80 % acceptable comfort range according to Adaptive Comfort Standard of American Society of Heating, Refrigerating and Air-Conditioning Engineers with optimum ventilation rate 414 m3/h for the hottest day. The findings show that the system achieves high performance in the hottest day with small solar chimney dimension and is easy to integrate in the building envelope than the proposed system before parametric studies in phase one.

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
AAAmr Sayed Hassan Abdallah
Amr Sayed Hassan Abdallah
Designing climatically responsive dwellings not only can achieve thermal comfort for occupants, but also can make a significant improvement in energy conservation. Consequently, interest in the microclimate around buildings in urban areas has increased because its affects other things; outdoor and indoor thermal comfort, energy consumption in heating and cooling, and the spreading of air pollution. This paper aims to investigate the influence of open spaces (outer courtyards) between building “Shallow canyons” with a H/W ratio of 0.24∼0.6 in one of the urban patterns of youth housing sectors in New Assiut city and deep canyons with a H/W ratio of 4 in one of the new residential houses (El-Abrahimia and El-Moalemen complexes) in the center of Assiut city on indoor thermal comfort. A comparison was made between the two cases based on indoor thermal comfort, energy consumption and IAQ in hot arid climate.The st**udy shows a decrease of indoor temperature inside living rooms that overlook the deep canyons in El-Abrahimia complex with a difference of 11°C from the outdoor in the hottest day of July. The design of deep canyons causes a temperature decrease of 6∼9.4°C compared to outdoor temperature in different points of the courtyard. Indoor temperature in these cases reach the upper limit of 90% acceptable range of ASHRAE during July with a maximum indoor temperature 32.5°C based on the strategy of using natural ventilation. The findings show decreases of cooling demand and energy consumption in deep canyons. This is considered a basic monitoring method that could be used in the future strategy of sustainable housing design of new cities in hot arid climate

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
AAAmr Sayed Hassan Abdallah
Amr Sayed Hassan Abdallah
Reducing energy use in buildings is a critical component of meeting carbon reduction commitments. Architects and engineers are the major players, making technical improvements to existing buildings and designing new ones with higher standards. The aim of the present research is to analyse indoor thermal comfort and energy consumption inside the large educational halls of the Faculty of Engineering, Assiut University, for determining the acceptable operative temperature for student comfort. Two approaches are presented; physical measurements and comfort surveys for 6 naturally ventilated halls. Several parameters were measured: indoor and outdoor air temperatures, wind speed, globe temperature, CO2 concentration and relative humidity. A questionnaire adapted from ASHRAE 2004 was answered by 269 respondents selected from a total of 331 respondents.The results showed that the indoor temperature exceeds 28°C and is far from 90% acceptable comfort range with high PMV range and PPD >10, particularly for female students with Islamic head veils (hijab) and 83% of the students prefer a cooler indoor climate. The lighting power ranges from 50% to 75%, and laptops ranges from 25% to 44% of total nominal electrical power. Also, the students’ thermal sensation ranges between warm and slightly warm in the six halls. The results of this research provide information for future indoor cooling design strategies and energy efficiency in large educational halls

2 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
AAAmr Sayed Hassan Abdallah
Amr Sayed Hassan Abdallah
RMRanda Mohamed Ahmed Mahmoud
Randa Mohamed Ahmed Mahmoud
MAMohammed Abdulrhman Aloshan
Mohammed Abdulrhman Aloshan
Improvement of recreational areas between the residential areas to achieve human behavior and the concept of humanization is urgently needed to achieve the 2030 vision of Saudi Arabia. This study aims to develop a parametric urban optimization framework to optimize the outdoor thermal comfort in outdoor recreational areas between residential buildings in Riyadh City, Saudi Arabia, based on the 2030 vision of Saudi Arabia to achieve a high standard of quality of life with thermal comfort. Measurement was conducted inside the sports walking path with walk-through observation and interviews. Then, case study geometry was generated computationally, using Rhinoceros software and its plug-in Grasshopper to implement the set of development scenarios. Then, the optimization process for the case study was integrated with 192 proposed development solutions to assess the solutions’ influence in reducing the Universal Thermal Comfort Index (UTCI) and average solar irradiance, besides increasing energy generated by PV panels. EnergyPlus engine and Ladybug plug-in are used to integrate PV panels with shading scenarios, to utilize the high solar irradiation, and to calculate the generated electrical energy. The results concluded that trees with diameters between 10 and 15 m could achieve thermal comfort and reduction UTCI by 11.26 K and average solar irradiance by 642.77 W/m2 with average energy generation of PV panel and optimum inclination angle of 20°. The integration of PV with shading scenarios generates electricity for every square meter of PV panel, equal to 578.84 kWh/m2 for lighting poles and service areas within the recreational areas. The results of this study help to improve the current park as a prototype, for which results can be implemented in more than 8100 instances of gardens, parks, and municipal squares in Saudi Arabia.