pierrick gouel

Dr. pierrick gouel

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2021 in Cancers
Verified
Journal Article
Open access
PDF file
THUREAU SébastienTHUREAU Sébastien
THUREAU Sébastien
NPNicolas Piton
Nicolas Piton
PGpierrick gouel
pierrick gouel
RMRomain Modzelewski
Romain Modzelewski
ADAntoine Dujon
Antoine Dujon
PVPierre Vera
Pierre Vera
Hypoxic areas are typically resistant to treatment. However, the fluorine-18-fluoroazomycin-arabinoside (FAZA) and fluorine 18 misonidazole (FMISO) tracers have never been compared in non small cell lung cancer (NSCLC). This study compares the capability of 18F-FAZA PET/CT with that of 18F-FMISO PET/CT for detecting hypoxic tumour regions in early and locally advanced NSCLC patients. We prospectively evaluated patients who underwent preoperative PET scans before surgery for localised NSCLC (i.e., fluorodeoxyglucose (FDG)-PET, FMISO-PET, and FAZA-PET). The PET data of the three tracers were compared with each other and then compared to immunohistochemical analysis (GLUT-1, CAIX, LDH-5, and HIF1-Alpha) after tumour resection. Overall, 19 patients with a mean age of 68.2 ± 8 years were included. There were 18 lesions with significant uptake (i.e., SUVmax >1.4) for the F-MISO and 17 for FAZA. The mean SUVmax was 3 (±1.4) with a mean volume of 25.8 cc (±25.8) for FMISO and 2.2 (±0.7) with a mean volume of 13.06 cc (±13.76) for FAZA. The SUVmax of F-MISO was greater than that of FAZA (p = 0.0003). The SUVmax of F-MISO shows a good correlation with that of FAZA at 0.86 (0.66–0.94). Immunohistochemical results are not correlated to hypoxia PET regardless of the staining. The two tracers show a good correlation with hypoxia, with FMISO being superior to FAZA. FMISO, therefore, remains the reference tracer for defining hypoxic volumes.

23 October 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
THUREAU SébastienTHUREAU Sébastien
THUREAU Sébastien
BDBernard Dubray
Bernard Dubray
RMRomain Modzelewski
Romain Modzelewski
Pierre BohnPierre Bohn
Pierre Bohn
SHSébastien Hapdey
Sébastien Hapdey
PVPierre Vera
Pierre Vera
Concomitant chemo-radiotherapy is the reference treatment for non-resectable locally-advanced Non-Small Cell Lung Cancer (NSCLC). Increasing radiotherapy total dose in the whole tumour volume has been shown to be deleterious. Functional imaging with positron emission tomography (PET/CT) offers the potential to identify smaller and biologically meaningful target volumes that could be irradiated with larger doses without compromising Organs At Risk (OAR) tolerance. This study investigated four scenarios, based on 18FDG and 18F-miso PET/CT, to delineate the target volumes and derive radiotherapy plans delivering up to 74Gy. Twenty-one NSCLC patients, selected from a prospective phase II trial, had 18FDG- and 18F-miso PET/CT before the start of radiotherapy and 18FDG PET/CT during the radiotherapy (42Gy). The plans were based planned on a standard plan delivering 66 Gy (plan 1) and on three different boost strategies to deliver 74Gy total dose in pre-treatment 18FDG hotspot (70% of SUVmax) (plan 2), pre-treatment 18F-miso target (SUVmax > 1.4) (plan 3) and per-treatment 18FDG residual (40% of SUVmax). (plan 4). The mean target volumes were 4.8 cc (± 1.1) for 18FDG hotspot, 38.9 cc (± 14.5) for 18F-miso and 36.0 cc (± 10.1) for per-treatment 18FDG. In standard plan (66 Gy), the mean dose covering 95% of the PTV (D95%) were 66.5 (± 0.33), 66.1 (± 0.32) and 66.1 (± 0.32) Gy for 18FDG hotspot, 18F-miso and per-treatment 18FDG. In scenario 2, the mean D95% was 72.5 (± 0.25) Gy in 18FDG hotspot versus 67.9 (± 0.49) and 67.9 Gy (± 0.52) in 18F-miso and per-treatment 18FDG, respectively. In scenario 3, the mean D95% was 72.2 (± 0.27) Gy to 18F-miso versus 70.4 (± 0.74) and 69.5Gy (± 0.74) for 18FDG hotspot and per-treatment 18FDG, respectively. In scenario 4, the mean D95% was 73.1 (± 0.3) Gy to 18FDG per-treatment versus 71.9 (± 0.61) and 69.8 (± 0.61) Gy for 18FDG hotspot and 18F-miso, respectively. The dose/volume constraints to OARs were matched in all scenarios. Escalated doses can be selectively planned in NSCLC target volumes delineated on 18FDG and 18F-miso PET/CT functional images. The most relevant strategy should be investigated in clinical trials. (RTEP5, NCT01576796 , registered 15 june 2012)

20 April 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
PGpierrick gouel
pierrick gouel
SHSebastien Hapdey
Sebastien Hapdey
ADArthur Dumouchel
Arthur Dumouchel
IGIsabelle Gardin
Isabelle Gardin
ETEva Torfeh
Eva Torfeh
DGDavid Gensanne
David Gensanne
Purpose: We aimed to evaluate the accuracy of T1 and T2 mappings derived from a multispectral pulse sequence (magnetic resonance image compilation, MAGiC®) on 1.5-T MRI and with conventional sequences [gradient echo with variable flip angle (GRE-VFA) and multi-echo spin echo (ME-SE)] compared to the reference values for the purpose of radiotherapy treatment planning.Methods: The accuracy of T1 and T2 measurements was evaluated with 2 coils [head and neck unit (HNU) and BODY coils] on phantoms using descriptive statistics and Bland–Altman analysis. The reproducibility and repeatability of T1 and T2 measurements were performed on 15 sessions with the HNU coil. The T1 and T2 synthetic sequences obtained by both methods were evaluated according to quality assurance (QA) requirements for radiotherapy. T1 and T2in vivo measurements of the brain or prostate tissues of two groups of five subjects were also compared.Results: The phantom results showed good agreement (mean bias, 8.4%) between the two measurement methods for T1 values between 490 and 2,385 ms and T2 values between 25 and 400 ms. MAGiC® gave discordant results for T1 values below 220 ms (bias with the reference values, from 38% to 1,620%). T2 measurements were accurately estimated below 400 ms (mean bias, 8.5%) by both methods. The QA assessments are in agreement with the recommendations of imaging for contouring purposes for radiotherapy planning. On patient data of the brain and prostate, the measurements of T1 and T2 by the two quantitative MRI (qMRI) methods were comparable (max difference, <7%).Conclusion: This study shows that the accuracy, reproducibility, and repeatability of the multispectral pulse sequence (MAGiC®) were compatible with its use for radiotherapy treatment planning in a range of values corresponding to soft tissues. Even validated for brain imaging, MAGiC® could potentially be used for prostate qMRI.

5 June 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PGpierrick gouel
pierrick gouel
FCFrançoise Callonnec
Françoise Callonnec
ÉLÉmilie Levêque
Émilie Levêque
CVCéline Valet
Céline Valet
ABAxelle Blôt
Axelle Blôt
BVBenjamin Viard
Benjamin Viard
The evaluation of tumor follow-up according to RECIST 1.1 has become essential in clinical practice given its role in therapeutic decision making. At the same time, radiologists are facing an increase in activity while facing a shortage. Radiographic technologists could contribute to the follow-up of these measures, but no studies have evaluated their ability to perform them. Ninety breast cancer patients were performed three CT follow-ups between September 2017 and August 2021. 270 follow-up treatment CT scans were analyzed including 445 target lesions. The rate of agreement of classifications RECIST 1.1 between five technologists and radiologists yielded moderate (k value between 0.47 and 0.52) and substantial (k value = 0.62 and k = 0.67) agreement values. 112 CT were classified as progressive disease (PD) by the radiologists, and 414 new lesions were identified. The analysis showed a percentage of strict agreement of progressive disease classification between reader-technologists and radiologists ranging from substantial to almost perfect agreement (range 73–97%). Analysis of intra-observer agreement was strong at almost perfect (k > 0.78) for 3 technologists. These results are encouraging regarding the ability of selected technologists to perform measurements according to RECIST 1.1 criteria by CT scan with good identification of disease progression.

22 March 2023 in Cancers
Verified
Journal Article
Open access
PDF file
PGpierrick gouel
pierrick gouel
FCFrançoise Callonnec
Françoise Callonnec
FOFranchel-Raïs Obongo-Anga
Franchel-Raïs Obongo-Anga
Pierre BohnPierre Bohn
Pierre Bohn
ELEmilie Lévêque
Emilie Lévêque
THUREAU SébastienTHUREAU Sébastien
THUREAU Sébastien
Intratumoral hypoxia is associated with a poor prognosis and poor response to treatment in head and neck cancers. Its identification would allow for increasing the radiation dose to hypoxic tumor subvolumes. 18F-FMISO PET imaging is the gold standard; however, quantitative multiparametric MRI could show the presence of intratumoral hypoxia. Thus, 16 patients were prospectively included and underwent 18F-FDG PET/CT, 18F-FMISO PET/CT, and multiparametric quantitative MRI (DCE, diffusion and relaxometry T1 and T2 techniques) in the same position before treatment. PET and MRI sub-volumes were segmented and classified as hypoxic or non-hypoxic volumes to compare quantitative MRI parameters between normoxic and hypoxic volumes. In total, 13 patients had hypoxic lesions. The Dice, Jaccard, and overlap fraction similarity indices were 0.43, 0.28, and 0.71, respectively, between the FDG PET and MRI-measured lesion volumes, showing that the FDG PET tumor volume is partially contained within the MRI tumor volume. The results showed significant differences in the parameters of SUV in FDG and FMISO PET between patients with and without measurable hypoxic lesions. The quantitative MRI parameters of ADC, T1 max mapping and T2 max mapping were different between hypoxic and normoxic subvolumes. Quantitative MRI, based on free water diffusion and T1 and T2 mapping, seems to be able to identify intra-tumoral hypoxic sub-volumes for additional radiotherapy doses.

10 September 2014 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
PDF file
SHSébastien Hapdey
Sébastien Hapdey
AEAgathe Edet-Sanson
Agathe Edet-Sanson
PGpierrick gouel
pierrick gouel
BMBenoît Martin
Benoît Martin
RMRomain Modzelewski
Romain Modzelewski
PVPierre Vera
Pierre Vera