The internal magnetic field characteristics of giant magnetostrictive actuators have an important influence on their output performance. Aiming at the deficiency of current scholars’ research, based on the electromagnetic theory and finite element method, this paper analyzes the magnetic field intensity on a giant magnetostrictive cylinder by using COMSOL Multiphysics software. Considering the inhomogeneity of magnetic field intensity along the radial direction of giant magnetostrictive cylinders, a new averaging method is introduced to calculate the magnetic field intensity in the axial section of the cylinder. The influence of the magnetic permeability of the displacement conversion mechanism (shell) and the size of the air gap inside the device on the magnetic field intensity of the giant magnetostrictive cylinder are analyzed. The prototype of the actuator is manufactured, and the correctness and accuracy of the simulation data are verified by experiments. In order to make the magnetic field on the cylinder strong and uniform, the displacement conversion mechanism and the shell should be made of low permeability and high permeability materials, respectively, and the air gap size should be reduced as much as possible under the condition of meeting the size requirement of the actuator pre-tightening force applying device.
At present, the research of electronically controlled injectors is mostly limited to the non-direct drive structure. Although the research on the direct drive structure is involved, it mostly stays in the conceptual machine or simulation stage. In this paper, based on the direct-drive structure, the giant magnetostrictive material is used as the energy conversion material, the prototype of the direct-drive giant magnetostrictive fuel injector is designed and manufactured, and the experimental test system and AMESim simulation model are built. By means of experiment and simulation, the injection characteristics of Giant magnetostrictive injector (GMI) are tested. It is found that the minimum single injection quantity of GMI is 5.9 mm3 under the condition of 30 MPa rail pressure, which shows high injection accuracy. The experimental results are in good agreement with the simulation results under different driving pulse widths and voltages. When the driving pulse width is not less than 650 µs, the relative errors are all less than 5%, which verifies the effectiveness of the simulation model. The injection performance of GMI is analyzed. The results show that this injector has a stable injection performance, fast response speed (the shortest injection pulse width is about 200 µs), and the injection process can be completed five times in 5 ms.
Aiming at the inherent problems of non-direct-drive injectors, such as long oil circuits and a difficult precise control of the needle stroke, based on the structure of a direct-drive injector and combined with the demand for the needle drive of a truck diesel injector, this study designs and fabricates a giant magnetostrictive actuator for direct-drive injectors. A simplified model of a giant magnetostrictive actuator is established, which mainly simplifies the magnetization model to facilitate the subsequent integrated modeling of the fuel injector. An actuator output displacement test system was built, and the output waveform and frequency characteristics of the actuator were analyzed. It was found that the experimental results were in good agreement with the calculated results of the model, and the average relative error of the amplitude was 3.26%, while the average relative error of the phase difference was 3.83%, which verifies the correctness of the model. This research enriches the modeling method of giant magnetostrictive actuators and has an important reference value for the research and design of fuel injectors.
The related parameters of electronically controlled injector have profound influence on the fuel injection performance of injector. However, most of the current researches focus on some parameters of actuator, but few on some parameters of nozzle. Based on the direct-drive giant magnetostrictive injector, the simulation model of this injector was built with AMEsim simulation software, and the effects of nozzle parameters such as half cone angle of needle valve, diameter of needle valve stem and diameter of nozzle hole on the injection performance of this injector were studied. In view of the many research parameters, the orthogonal experiment method was adopted to design the experimental scheme reasonably, and finally L16 (45) orthogonal experimental table was selected for the experiment. The results show that the parameters that have the greatest and smallest influence on the fuel injection performance of this injector are the cavity parameters and the number of injection holes. The optimum combination of nozzle parameters was obtained, and the fuel injection performance of injectors before and after the optimization of nozzle parameters was compared. It was found that the optimized combination of nozzle parameters had a better correspondence between fuel injection rate and needle valve displacement, which provided the possibility for further improving the flexibility of fuel injection rate.