Highly accurate sample drift correction is essential in super-resolution localization microscopy to guarantee a high spatial resolution, especially when the technique is used to visualize small cell organelle. Here we present a localization events-based drift correction method using a redundant cross-correlation algorithm originally developed to correct beam-induced motion in cryo-electron microscopy. With simulated, synthesized as well as experimental data, we have demonstrated its superior precision compared to previously published localization events-based drift correction methods. The major advantage of this method is the robustness when the number of localization events is low, either because a short correction time step is required or because the imaged structure is small and sparse. This method has allowed us to improve the effective resolution when imaging Golgi apparatus in mammalian cells.
We report the synthesis of a dithienylethene–tetraphenylethene (DTE–TPE) conjugated photochromic fluorophore which simultaneously exhibits aggregation-induced emission and reversible fluorescence switching. Photochromic DTE–TPE turns cyan-blue after 5 s of UV irradiation and exhibits a strong green emission at 520–540 nm upon excitation with visible light when present in nanoparticles and the solid state, in contrast to non-fluorescence in solution. DTE–TPE exhibits reversible fluorescence switching under alternating irradiation with UV and visible light (wavelengths greater than 440 nm), when present in nanoparticles and the solid state. The continuous readout of the emissive DTE–TPE film over 1 h upon 440 nm excitation–irradiation causes only a 7% reduction in emission intensity for DTE–TPE. The super-resolution fluorescence nanolocalization indicates that the vicinal DTE–TPE emitters show sub-100 nm resolution which is higher than for conventional fluorescent imaging. The spectroscopic and imaging data provides initial guidelines for the screening of molecular scale memory units with the corresponding excitation and detection wavelengths for signal readout and super-resolution imaging agents.
Localization-based super-resolution microscopy (or called localization microscopy) rely on repeated imaging and localization of active molecules, and the spatial resolution enhancement of localization microscopy is built upon the sacrifice of its temporal resolution. Developing algorithms for high-density localization of active molecules is a promising approach to increase the speed of localization microscopy. Here we present a new algorithm called SSM_BIC for such purpose. The SSM_BIC combines the advantages of the Structured Sparse Model (SSM) and the Bayesian Information Criterion (BIC). Through simulation and experimental studies, we evaluate systematically the performance between the SSM_BIC and the conventional Sparse algorithm in high-density localization of active molecules. We show that the SSM_BIC is superior in processing single molecule images with weak signal embedded in strong background.
In the community of localization-based super-resolution microscopy (or called localization microscopy), it is generally believed that the emission of single molecules is so weak that an EMCCD (electron multiplying charge coupled device) camera is necessary to be used as the detector by eliminating read noise. Here we evaluate the possibility of a new kind of low light detector, scientific complementary metal-oxide-semiconductor (sCMOS) camera in localization microscopy. We demonstrate experimentally that sCMOS is capable of imaging actin bundles with FWHM diameter of 37 nm, evidencing the capability of sCMOS in localization microscopy. We further characterize the noise performance of sCMOS and find out that, with the use of a bright fluorescence probe such as d2EosFP, localization microscopy imaging is now working in the shot noise limited region.