Gwenael GABORIT

Gwenael GABORIT


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2013 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
Gwenael GABORITGwenael GABORIT
Gwenael GABORIT
JDJean Dahdah
Jean Dahdah
FLFrederic Lecoche
Frederic Lecoche
PJPierre Jarrige
Pierre Jarrige
YGYann Gaeremynck
Yann Gaeremynck
LDLionel Duvillaret
Lionel Duvillaret
Pulsed power and intense electric field now apply to a large variety of domains for which the need of in situ nonperturbative measurements remains a challenge. The main requirements that sensors should fulfill for that purpose are nonmetallic composition, small size, ultrawide bandwidth, compatibility with liquids and gases, possibility for remote measurements at long distances, true vectorial (field direction) time-domain measurements, capability of measuring electric fields up to the electric breakdown of air, and a large dynamic range. Obviously, all these requirements cannot be achieved by a unique sensor. However, most of them are fulfilled by pigtailed electrooptic (EO) sensors. In this paper, after recalling the principle of the EO effect and its use for electric field measurement, we deal with the measurement linearity and selectivity of the EO sensor. Associated with the nonperturbative behavior of the EO sensor, the measurement dynamics of EO sensors exceeds 100 dB. Furthermore, EO sensors present an intrinsic flat response from quasi d.c. (10 Hz) up to a few tens of gigahertz. Thanks to their composition of high dielectric strength materials and their optical pigtail, EO sensors are completely immune to the electromagnetic environment except on a very small volume (≅ 10 mm3) corresponding to the transducer element of the sensor. This leads to a very high spatial resolution. We finally illustrate the capabilities of this technology through in situ measurement of the electric discharge transients and vectors.

30 January 2014 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
Gwenael GABORITGwenael GABORIT
Gwenael GABORIT
PJPierre Jarrige
Pierre Jarrige
FLFrederic Lecoche
Frederic Lecoche
JDJean Dahdah
Jean Dahdah
EDEric Duraz
Eric Duraz
LDLionel Duvillaret
Lionel Duvillaret
In this paper we illustrate the ability of electrooptic sensors to perform electric (E)-field vectorial measurements. Thanks to their frequency response spreading over nine decades and to their measurement dynamics reaching 120 dB, these sensors are of high interest for some applications (near field mapping, energy line monitoring, electromagnetic compatibility, and so on). Furthermore, due to their fully dielectric structure and millimetric size, almost no perturbation is induced on the E-field to be measured, even in the near field region. This paper is focused on high-intensity pulsed E-field characterization in different environments such as air, water (bioelectromagnetism applications), or plasmas (in situ assessment of the E-field associated to an electric discharge and to the induced plasma). The use of such a technology for electrical equipment and energy line monitoring is also investigated.

29 April 2008 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MBMaxime Bernier
Maxime Bernier
Gwenael GABORITGwenael GABORIT
Gwenael GABORIT
LDLionel Duvillaret
Lionel Duvillaret
APAlain Paupert
Alain Paupert
JLJean-Louis Lasserre
Jean-Louis Lasserre
We present pigtailed electro-optic probes that allow a simultaneous measurement of high frequency electric fields and temperature using a unique laser probe beam. This has been achieved by the development of a novel probe design associated with a fully automated servo-controlled optical bench, initially developed to stabilize the electric field sensor response. The developed electro-optic probes present a stable response in outdoors conditions over a time duration exceeding 1 h, a frequency bandwidth from kHz to tens of GHz with a sensitivity of 0.7 Vm−1Hz−1/2, and a temperature accuracy of 40 mK.

11 June 2007 in Applied Physics Letters
Verified
Journal Article
Closed access
Gwenael GABORITGwenael GABORIT
Gwenael GABORIT
JCJ.-L. Coutaz
J.-L. Coutaz
LDL. Duvillaret
L. Duvillaret
The authors present a two-component electric field measurement using a single electro-optic crystal and a single laser probe beam. This vectorial electric field measurement based on polarization state modulation is possible using isotropic electro-optic crystals for which directions of the eigendielectric axes are directly linked to the direction of the applied electric field. The proposed method can be used either for continuous wave or single shot measurements as the two electric field components are measured simultaneously.

3 October 2011 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YGYann Gaeremynck
Yann Gaeremynck
Gwenael GABORITGwenael GABORIT
Gwenael GABORIT
LDLionel Duvillaret
Lionel Duvillaret
MRMickaël Ruaro
Mickaël Ruaro
FLFrédéric Lecoche
Frédéric Lecoche
Based on an isotropic electro-optic crystal, a two-port pigtailed electro-optic sensor has been built. The probe allows to measure two orthogonal components of the ambient electric field. The sensor intrinsically presents a temperature-dependent free response. The two measured electric field components are orthogonal to the sensor revolution axis, leading to a transverse electro-optic probe. Magnitude and orientation of the electric field are measured simultaneously with an accuracy of 0.5 dB and 2°, respectively. The rejection of orthogonal components to the electric field vector reaches 30 dB.

12 December 2008 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MBMaxime Bernier
Maxime Bernier
LDLionel Duvillaret
Lionel Duvillaret
Gwenael GABORITGwenael GABORIT
Gwenael GABORIT
APAlain Paupert
Alain Paupert
JLJean-Louis Lasserre
Jean-Louis Lasserre
We present, in this paper, pigtailed electro-optic sensors dedicated to the measurement of high-power microwave signals in outdoors conditions. We give results on high-power microwave single-shot pulses obtained with long fiber links (> 20 m) in hard environmental conditions (temperature variations up to 30degC). In these awkward outdoors conditions, we obtain very stable measurements with rms signal fluctuations lower than 0.2 dB. We focus here especially on the design of the temperature-dependent-free system.