Abdelghani Iddar

Dr. Abdelghani Iddar

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2021 in Journal of Environmental Science and Health, Part B
Verified
Journal Article
Closed access
NBNajwa Bellemjid
Najwa Bellemjid
AAAli Assifaoui
Ali Assifaoui
AMAhmed Moussaif
Ahmed Moussaif
NANajia El Abbadi
Najia El Abbadi
AMAbdelhalim Mesfioui
Abdelhalim Mesfioui
AIAbdelghani Iddar
Abdelghani Iddar
This study aims to encapsulate the fungicide carbendazim using a biodegradable polymer (pectin). First, we have obtained calcium pectinate beads (CPG-Carb) by ionotropic gelation using calcium ions as a crosslinking agent. These beads were then coated with silica starting from tetraethoxysilane (TEOS), by a sol-gel process to form hybrid beads (CPG-Carb-SG). The morphology, composition and structure of both beads were characterized and the controlled release assays of the fungicide were studied in both water and soil columns. The encapsulation efficiency for CPG-Carb was slightly higher (75%) compared to CPG-Carb-SG (67%) due to carbendazim loss during the impregnation and condensation steps. The release rate in water and soil columns was about 4 times lower for CPG-Carb-SG than CPG-Carb demonstrating the efficiency of the silica coating to delay the release of carbendazim. Moreover, the release of CPG-Carb-SG is due to the erosion of the silica layer during the first two weeks. After this period, the silica layer was degraded, and the release is then controlled by the swelling of the organic part of the bead as observed for CPG-Carb. Finally, the biodegradability of the pectin, and the release profile make such systems promising candidates for sustained and economical pesticide delivery systems.

1 February 2007 in Acta Biochimica et Biophysica Sinica
Verified
Journal Article
Open access
PDF file
LFLatifa Fourrat
Latifa Fourrat
AIAbdelghani Iddar
Abdelghani Iddar
ASAbdelaziz Soukri
Abdelaziz Soukri
Glyceraldehyde-3-phosphate dehydrogenase (GAPDH) (EC 1.2.1.12), a key enzyme of carbon metabolism, was purified and characterized to homogeneity from

7 February 2025 in Toxicological & Environmental Chemistry
Verified
Journal Article
Closed access
SMSaloua Mabsor-Zgandaoui
Saloua Mabsor-Zgandaoui
KRKhawla Rachmoune
Khawla Rachmoune
AHAboubaker El Hessni
Aboubaker El Hessni
MMMohammed EL MZIBRI
Mohammed EL MZIBRI
AIAbdelghani Iddar
Abdelghani Iddar
AMAdnane Moutaouakkil
Adnane Moutaouakkil

11 August 2019 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
IMI. Maftouh
I. Maftouh
AIAbdelghani Iddar
Abdelghani Iddar
AMA. Moussaif
A. Moussaif
NAN El Abbadi
N El Abbadi
AMA. Mesfioui
A. Mesfioui
A competitive enzyme-linked immunosorbent assay (ELISA) test using polyclonal rabbit antibodies for detection of Chlorpyrifos-ethyl (CPE) and its two major metabolites of degradation [3,5,6-Trichlororpyridin-2-ol (TCP) and O,O’-diethylthiophosphoric acid (DETP)], has been developed. We have first synthetized haptens of these three molecules, with 4 and 5 carbons spacer arms having carboxyl function at their ends. Haptens with 5 carbons’ spacer arm have been coupled to Bovine Serum Albumin (BSA) then injected to rabbits for polyclonal antibodies production. Haptens with 4 carbons spacer arm have been coupled to Human Albumin (HAS) to be in well plates coating to perform the ELISA tests. After adjusting the ELISA parameters, we have plotted the B/B0 (%) values against the logarithm of analyst concentrations. The IC50 values and detection limits were obtained through fitting the curves. The IC50 value of CPE and TCP were 651 and 5.61 ppb, with detection limits about 2.3410−2 and 2.18 10−3 ppb, respectively. We report for the first time, ELISA system developed for DETP with IC50 of 76.5 and a detection limit of 8.81 10−3 ppb. To evaluate the potential interferences that may be encountered in environmental water samples, pH, ionic strength, humic acid and some heavy metals were tested upon IC50 of the developed ELISA systems. In addition, several pesticides as well as CPE metabolites were tested for cross reactivity study. In all cases, the interference of the CPE assay was negligible. TCP assay represented a high cross reactivity to CPE but no interference with the others compounds. For DETP, no cross reactivity with the TCP was detected, but it was higher with CPE and the others pesticides. The developed ELISA systems have been compared with HPLC technique. Both techniques gave values of the same order of CPE and TCP prepared concentrations with a better sensitivity for ELISA system.

10 October 2024 in International Journal of Environmental Studies
Verified
Journal Article
Closed access
SMSaloua Mabsor-Zgandaoui
Saloua Mabsor-Zgandaoui
AMAhmed MOUSSAIF
Ahmed MOUSSAIF
AHAboubaker El Hessni
Aboubaker El Hessni
AMAbdelhalem Mesfioui
Abdelhalem Mesfioui
MMMohammed EL MZIBRI
Mohammed EL MZIBRI
AMAdnane Moutaouakkil
Adnane Moutaouakkil

26 February 2021 in Journal of Immunoassay and Immunochemistry
Verified
Journal Article
Closed access
YSYounes Sbihi
Younes Sbihi
NANajia El Abbadi
Najia El Abbadi
AIAbdelghani Iddar
Abdelghani Iddar
Congenital hypothyroidism (CH) is one of the most common preventable causes of mental retardation. The majority of infants are diagnosed after detection through newborn screening programs using thyroid-stimulating hormone (TSH) test. A rapid immunochromatographic lateral flow assay based on monoclonal antibodies (MAbs) colloidal gold nanoparticles was developed in a sandwich format for the detection of TSH. Two MAbs binding distinct TSH epitopes are used; one is conjugated to the detection reagent while the other is immobilized at the test line on the membrane. The colloidal gold was prepared by the reduction of gold salt coupled with MAbs and this optimal concentration was determined by spectrophotometry method. The sensitivity of our developed lateral flow immunoassay was determined using 5, 10, 15, 25 and 50 μUI/mL of TSH. The color intensity of the test line was directly proportional to the TSH concentration and the visual limit of detection was 10 μUI/mL. Twenty samples of umbilical cord serum were analyzed by the developed strips and the intensity of the signal was in agreement with the results obtained by the conventional radioimmunoassay method. The results suggest that this rapid test can be used in initial screening for congenital hypothyroidism especially in rural areas.