Mohamed Shaaban Eissa

Dr. Mohamed Shaaban Eissa

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Mahmoud Badawy ElshenitiMahmoud Badawy Elsheniti
Mahmoud Badawy Elsheniti
Ahmed RezkAhmed Rezk
Ahmed Rezk
MEMohamed Shaaban Eissa
Mohamed Shaaban Eissa
MRMohamed Roshdy
Mohamed Roshdy
YNYahia Mohamed Nagib
Yahia Mohamed Nagib
BSBidyut Baran Saha
Bidyut Baran Saha

8 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
Mahmoud Badawy ElshenitiMahmoud Badawy Elsheniti
Mahmoud Badawy Elsheniti
MEMohamed Shaaban Eissa
Mohamed Shaaban Eissa
HAHany Al-Ansary
Hany Al-Ansary
Jamel OrfiJamel Orfi
Jamel Orfi
OEOsama Ahmed Elsamni
Osama Ahmed Elsamni
AEAbdelrahman El-Leathy
Abdelrahman El-Leathy
Producing ice using adsorption systems can represent a sustainable solution and meet the recent global environmental regulations as they use natural refrigerants and can be driven by solar energy. However, the beds used in these systems still have low thermal and adsorption characteristics. This study investigates numerically the use of an emerging aluminum foamed bed packed with advanced Maxsorb adsorbent in a two-bed adsorption system and reports cases of performance improvements compared to the classical finned-tube based system used to produce ice. A comprehensive 2-D transient pressure distribution model for the two beds was developed and validated. The model considers the temporal and spatial variations of the two beds’ parameters, while the effect of the thermal mass and heat transfer effectiveness of the condenser and evaporator components are imitated at the boundary conditions for bed openings using two zero-dimensional models. The results show the interrelated effects of varying the cycle times from 400 s to 1200 s with 2, 5, and 10 mm foam thicknesses/fin heights on the overall performance of both systems. The Al-foam based system demonstrated the performance superiority at a 2 mm foam thickness with maximum ice production of 49 kgice/kgads in 8 h, an increase of 26.6% over the counterpart finned-tube based system at a 400 s cycle time. The best COP of 0.366 was attained at a 5 mm foam thickness and 1200 s with an increase of 26.7%. The effective uptake of the Al-foam based system was reduced dramatically at a 10 mm foam thickness, which deteriorated the system performance.

28 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Mahmoud Badawy ElshenitiMahmoud Badawy Elsheniti
Mahmoud Badawy Elsheniti
MEMohamed Shaaban Eissa
Mohamed Shaaban Eissa
HAHany Al-Ansary
Hany Al-Ansary
Jamel OrfiJamel Orfi
Jamel Orfi
AEAbdelrahman El-Leathy
Abdelrahman El-Leathy
OEOsama Ahmed Elsamni
Osama Ahmed Elsamni
Adsorption refrigeration systems are one of the emerging decarbonization technologies that can use eco-friendly heating sources and working fluids. However, the highly porous adsorbent materials used in these systems have a low thermal conductivity that hinders their system performance enhancement. Graphene nanoplatelets are proposed in the literature to improve the conductive heat transfer through the adsorbent field and the resulting composite adsorbents were favorably testified at the material level. In this study, the impact of employing a composite adsorbent that comprises of 50% activated carbon type Maxsorb III, 40% graphene nanoplatelets, and 10% binder was numerically investigated at a system level. The contradictory effects of heat and mass transfer mechanisms within the composite adsorbent on the performance of an adsorption ice production system were explored for three cases of composite layer thicknesses at different cycle times. The results showed that the maximum specific daily ice production and coefficient of performance of 33.27 kgice·kgads−1·day−1 and 0.3046 were attained at composite thicknesses of 2 and 5 mm and cycle times of 430 and 1230 s, respectively. The higher composite thickness of 10 mm increased the mass transfer resistances, which overlooked the enhancement in the heat transfer and reduced the overall performance.