James Brazdzionis

Dr. James Brazdzionis


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2023 in Cureus
Verified
Journal Article
Open access
PDF file
JBJames Brazdzionis
James Brazdzionis
MRMohamed M. Radwan
Mohamed M. Radwan
FTFinosh Thankam
Finosh Thankam
YMYssel Mendoza Mari
Yssel Mendoza Mari
DBDavid Baron
David Baron
DMDan E Miulli
Dan E Miulli
Background Neurologic diseases have profound disability, mortality, and socioeconomic effects worldwide. Treatment of these disorders varies but is largely limited to unique factors associated with neural physiology. Early studies have evaluated alterations in electromagnetic fields (EMF) due to neural disorders with subsequent modulation of EMF as a potential treatment modality. Swine models have begun to be evaluated as translational models in this effect. Methods EMF measurements of a Yucatan miniswine were recorded using proprietary non-contact, non-invasive induction sensors with a dual layer Mu-metal and interlaced copper mesh helmet. The swine then underwent controlled cortical impact (CCI) to simulate traumatic brain injury (TBI). Twenty minutes post-injury after surgical wound closure, the swine underwent targeted EMF signal modulation using a signal generator to stimulate the swine's injured cortical circuit using a sinusoidal wave individualized at 2.5 Hz with a 500mV positive offset at 1V. After 10 days of stimulation, settings were modified to another individualized frequency of 5.5 Hz, 500mV positive offset and 1V for stimulation. Behavioral patterns in swine were evaluated, and EMF measurements were recorded daily prior to, during, and after stimulation. Artificial intelligence (AI) models evaluated patterns in EMF signals. Histology of the stimulated swine cortex was evaluated using hematoxylin and eosin staining and pentachrome staining and compared to a control swine without stimulation and a swine that had received stimulation two days post-injury in a delayed fashion. Serial serum specimens and tissue at the time of euthanasia were obtained for assessment of neuron-specific enolase (NSE) concentration. Results Pre-operative and post-stimulation measurements demonstrated differences in patterns and activity early on. There was an identified peak at 1.6Hz, not frequently seen pre-operatively. There were convergent frequencies in both data sets at 10.5 Hz and 3.9 Hz. Plateaus and decreased variability of changes in slope were identified early in the post-injury phase. AI modeling identified early similarities in pre-operative and post-stimulation measurements through the patterns of peaks with similarities on postoperative day 10 and similarities in the valleys on postoperative day 17. Histologic specimens identified increased degrees of apoptosis and cellular death in the non-stimulated control compared to the stimulated swine. Similarly, the immediately stimulated swine had less apoptosis and increased histologic viability at the site of injury compared to the two-day delayed stimulation swine. There were increased levels of NSE noted in the stimulated swine at the site of injury compared to non-injured sites and the control swine. Conclusions Cortical function was appropriately measured through induction sensors and shielding in the form of a helmet and electromagnetic field channels. Early stimulation resulted in the early and durable recovery of neuronal circuit-driven electromagnetic field patterns. Histology identified increased viability of neurons with fewer apoptotic neurons and glial cells in stimulated swine with early stimulation identifying the best effect compared to a non-stimulated subject. This recovery identifies change and recovery at the circuit, cellular, and subcellular levels that potentiate the need for further study of EMF modulation as a treatment modality in neurological disorders.

26 August 2019 in Cureus
Verified
Journal Article
Open access
PDF file
SPStacey Podkovik
Stacey Podkovik
HTHarjyot Toor
Harjyot Toor
MGMaya Gattupalli
Maya Gattupalli
SKSamir Kashyap
Samir Kashyap
JBJames Brazdzionis
James Brazdzionis
SWSharon Wang
Sharon Wang
Background: Hospital-acquired infections (HAIs) are profound causes of prolonged hospital stay and worse patient outcomes. HAIs pose serious risks, particularly in neurosurgical patients in the intensive care unit, as these patients are seldom able to express symptoms of infection, with only elevated temperatures as the initial symptom. Data from Center for Disease Control (CDC) and the Infectious Disease Society of America (IDSA) have shown that of all HAIs, urinary tract infections (UTIs) have been grossly over-reported, resulting in excessive and unnecessary antibiotic usage. Methods: We conducted a retrospective analysis of 686 adult patients that were evaluated by the neurosurgery service at Arrowhead Regional Medical Center between July 2018 and March 2019. Inclusion criteria were adults greater than 18 years of age with neurosurgical pathology requiring a minimum of one full day admission to the intensive care unit (ICU), and an indwelling urinary catheter. Exclusion criteria were patients under the age of 18, those who did not spend any time in the ICU, or with renal pathologies such as renal failure. Results: We reviewed 686 patients from the neurosurgical census. In total, 146 adult patients with indwelling urinary catheters were selected into the statistical analysis. Most individuals spent an average of 8.91 ± 9.70 days in the ICU and had an indwelling catheter for approximately 8.14 ± 7.95 days. Forty-two out of the 146 individuals were found to have a temperature of 100.4°F or higher. Majority of the patients with an elevated temperature had an infectious source other than urine, such as sputum (22 out of 42, 52.38%), blood (three out of 42, 7.14%) or CSF (one out of 42, 2.38%). We were able to find only two individuals (4.76%) with a positive urine culture and no evidence of other positive cultures or deep vein thrombosis. Conclusions: Our analysis shows evidence to support the newest IDSA guidelines that patients with elevated temperatures should have a clinical workup of all alternative etiologies prior to testing for a urinary source unless the clinical suspicion is high. This will help reduce the rate of unnecessary urine cultures, the over-diagnosis of asymptomatic bacteriuria, and the overuse of antibiotics. Based on our current findings, all potential sources of fever should be ruled out prior to obtaining urinalysis, and catheters should be removed as soon as they are not needed. Urinalysis with reflex to urine culture should be reserved for those cases where there remains a high index of clinical suspicion for a urinary source.

29 March 2022 in Cureus
Verified
Journal Article
Open access
JBJames Brazdzionis
James Brazdzionis
JWJames Wiginton
James Wiginton
TPTye Patchana
Tye Patchana
PSParas Savla
Paras Savla
JHJames Hung
James Hung
DMDan E Miulli
Dan E Miulli
The electromagnetic field (EMF) of the human brain generated by the movement of ions in the brain can be measured in a novel manner. The measurement can be completed through the skull, in a non-contact, non-invasive, continuous manner using a lightweight helmet. This investigation was conducted to determine if brain activity from movement and thoughts of movement can be measured at a distance and if that measurement can be readily evaluated at a distance using shielding with a shielded helmet and a shielded EMF channel surrounding a sensor. Non-clinical human subject volunteers donned a lightweight sensor helmet and performed a variety of specific tasks synchronized with an audible tone generated by a metronome. Constructs were created to determine if the human subjects’ brain EMF can be recorded at a distance using sensors surrounded by shielding acting similar to a waveguide in an EMF channel connected to a shielded helmet. The EMF sensors appeared to record brain electromagnetic activity as it is funneled into a shielded channel acting as a waveguide at a considerable distance including distances as far as 63 cm away. Specific brain EMFs from movement, thoughts of movement, and emotional thought can be continuously measured in a non-contact fashion at a distance using an EMF waveguide approach with an EMF channel and shielded helmet.

20 March 2022 in Cureus
Verified
Journal Article
Open access
JWJames Wiginton
James Wiginton
JBJames Brazdzionis
James Brazdzionis
TPTye Patchana
Tye Patchana
PSParas Savla
Paras Savla
JHJames Hung
James Hung
DMDan E Miulli
Dan E Miulli
In this study, a novel method of electromagnetic field (EMF) measurements of the human brain has been performed to evaluate neuronal activity. This measurement in a non-contact, non-invasive, continuous manner through the human skull and scalp in the standard environment is completed through a lightweight inexpensive helmet. We sought to further delineate whether specific activities of complex thought can be identified using this non-invasive technique. Non-clinical human subject volunteers donned a lightweight helmet with attached sensors and performed activities of motor movement, specific motor imagery, and specific emotional imagery synchronized to an audible tone for consistency. The human subjects’ brain EMF was recorded and analyzed. The novel method of continuously recording real-time human brain EMF was able to determine differing brain activity between individuals performing motor movement, motor imagery, and emotional imagery in a non-contact manner at different distances from the scalp. It may be possible to measure specific human brain activity using EMF in a non-invasive fashion. Emotional imagery, motor imagery, and motor movement generate different EMFs that have different discernible forms compared to baseline activity.

9 March 2022 in Cureus
Verified
Journal Article
Open access
JBJames Brazdzionis
James Brazdzionis
JWJames Wiginton
James Wiginton
TPTye Patchana
Tye Patchana
PSParas Savla
Paras Savla
JHJames Hung
James Hung
DMDan E Miulli
Dan E Miulli
The actions of neurons are dependent on electrochemical signal pathways mediated by neurotransmitters and create measurable electrical charges. These charges have been found to be measurable through neuroimaging technologies and now through a novel non-contact non-invasive sensor without supercooling. Identifying whether this technology can be appropriately interpreted with synchronized motor well-defined activities in vivo may allow for further clinical applications. A non-contact, non-invasive helmet constructed and modified using shielding technology with proprietary magnetic field sensors was utilized to measure the brain’s electromagnetic field (EMF). Human volunteers donned helmets and were asked to perform repetitive tapping exercises in order to identify waves consistent with tapping from the left and right hemispheres. A gyroscope was utilized to ensure that measured waves were not from micro-movement but were from neuronal firing. Multiple individuals were tested to evaluate the reproducibility of tapping and commonalities between individuals Right and left-sided tapping generated discernible wave changes from baseline measurements obtained by the helmet without a subject as well as differed from when the subject was at rest. Wave patterns varied from person to person but were overall similar in each subject individually. Shielding was necessary to identify signals but EMF was identified when shielding was transitioned from around the helmet to within the helmet design. It is possible to measure in-vivo electromagnetic fields generated by the human brain generated by stereotyped tasks in a non-contact non-invasive manner. These waves were reliably obtained within each individual with some variability in morphology from subject to subject however were similar in each subject. Signals varied based on activity and stereotyped motor activities were identified. A helmet using shielding technology within the helmet itself was able to effectively identify EMF signals. Future analysis may focus on translating these waves into functional mapping for clinical applications.

7 February 2022 in Cureus
Verified
Journal Article
Open access
JWJames Wiginton
James Wiginton
JBJames Brazdzionis
James Brazdzionis
TPTye Patchana
Tye Patchana
JHJames Hung
James Hung
YZYongming Zhang
Yongming Zhang
DMDan E Miulli
Dan E Miulli
Advancements in neuroimaging have changed the field of medicine. Computed tomography (CT) and magnetic resonance imaging (MRI) typically produce a static image of the brain, while continuous electroencephalogram (EEG) data is limited to the cortical surface. The brain’s chemical reactions produce an electric circuit that generates a magnetic field. We seek to test the ability of a non-contact sensor to measure the human brain’s electromagnetic field (EMF). A lightweight, inexpensive construct was designed to hold EMF sensors to non-invasively measure the human brain’s dynamic EMF. Measurements were conducted on non-clinical human volunteers. Background data without the human subjects was obtained, followed by introducing human subjects. Motionless human subject data was obtained, followed by a subject performing a task. Finally, a subject received auditory stimulation, and data was obtained. Our non-contact sensor was able to detect a difference between background activity without a human subject and the electromagnetic field of a human brain within the scalp and skull. Detectable differences in magnetic field potential were also obtained when the subject performed a task and received auditory stimulation. It is possible to continuously measure living human brain dynamic electromagnetic fields throughout the entire brain in a non-contact, non-invasive, continuous manner through the human scalp and skull in the standard environment. The signals are unique to the individual human and can be differentiated from background activity.