Takaaki Yoshimura

Dr. Takaaki Yoshimura

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2024 in Echocardiography
Verified
Journal Article
Closed access
MMMichito Murayama
Michito Murayama
HSHiroyuki Sugimori
Hiroyuki Sugimori
TYTakaaki Yoshimura
Takaaki Yoshimura
SKSanae Kaga
Sanae Kaga
HSHideki Shima
Hideki Shima
ITIchizo Tsujino
Ichizo Tsujino

31 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
TYTakaaki Yoshimura
Takaaki Yoshimura
AHAtsushi Hasegawa
Atsushi Hasegawa
SKShoki Kogame
Shoki Kogame
KMKeiichi Magota
Keiichi Magota
RKRina Kimura
Rina Kimura
Hiroyuki SugimoriHiroyuki Sugimori
Hiroyuki Sugimori
In positron emission tomography (PET) imaging, image quality correlates with the injected [18F]-fluorodeoxyglucose (FDG) dose and acquisition time. If image quality improves from short-acquisition PET images via the super-resolution (SR) deep learning technique, it is possible to reduce the injected FDG dose. Therefore, the aim of this study was to clarify whether the SR deep learning technique could improve the image quality of the 50%-acquisition-time image to the level of that of the 100%-acquisition-time image. One-hundred-and-eight adult patients were enrolled in this retrospective observational study. The supervised data were divided into nine subsets for nested cross-validation. The mean peak signal-to-noise ratio and structural similarity in the SR-PET image were 31.3 dB and 0.931, respectively. The mean opinion scores of the 50% PET image, SR-PET image, and 100% PET image were 3.41, 3.96, and 4.23 for the lung level, 3.31, 3.80, and 4.27 for the liver level, and 3.08, 3.67, and 3.94 for the bowel level, respectively. Thus, the SR-PET image was more similar to the 100% PET image and subjectively improved the image quality, as compared to the 50% PET image. The use of the SR deep-learning technique can reduce the injected FDG dose and thus lower radiation exposure.

21 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SISoichiro Inomata
Soichiro Inomata
TYTakaaki Yoshimura
Takaaki Yoshimura
MTMinghui Tang
Minghui Tang
SIShota Ichikawa
Shota Ichikawa
Hiroyuki SugimoriHiroyuki Sugimori
Hiroyuki Sugimori
Cardiac function indices must be calculated using tracing from short-axis images in cine-MRI. A 3D-CNN (convolutional neural network) that adds time series information to images can estimate cardiac function indices without tracing using images with known values and cardiac cycles as the input. Since the short-axis image depicts the left and right ventricles, it is unclear which motion feature is captured. This study aims to estimate the indices by learning the short-axis images and the known left and right ventricular ejection fractions and to confirm the accuracy and whether each index is captured as a feature. A total of 100 patients with publicly available short-axis cine images were used. The dataset was divided into training:test = 8:2, and a regression model was built by training with the 3D-ResNet50. Accuracy was assessed using a five-fold cross-validation. The correlation coefficient, MAE (mean absolute error), and RMSE (root mean squared error) were determined as indices of accuracy evaluation. The mean correlation coefficient of the left ventricular ejection fraction was 0.80, MAE was 9.41, and RMSE was 12.26. The mean correlation coefficient of the right ventricular ejection fraction was 0.56, MAE was 11.35, and RMSE was 14.95. The correlation coefficient was considerably higher for the left ventricular ejection fraction. Regression modeling using the 3D-CNN indicated that the left ventricular ejection fraction was estimated more accurately, and left ventricular systolic function was captured as a feature.

30 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KUKousuke Usui
Kousuke Usui
TYTakaaki Yoshimura
Takaaki Yoshimura
MTMinghui Tang
Minghui Tang
Hiroyuki SugimoriHiroyuki Sugimori
Hiroyuki Sugimori
Estimation of human age is important in the fields of forensic medicine and the detection of neurodegenerative diseases of the brain. Particularly, the age estimation methods using brain magnetic resonance (MR) images are greatly significant because these methods not only are noninvasive but also do not lead to radiation exposure. Although several age estimation methods using brain MR images have already been investigated using deep learning, there are no reports involving younger subjects such as children. This study investigated the age estimation method using T1-weighted (sagittal plane) two-dimensional brain MR imaging (MRI) of 1000 subjects aged 5–79 (31.64 ± 18.04) years. This method uses a regression model based on ResNet-50, which estimates the chronological age (CA) of unknown brain MR images by training brain MR images corresponding to the CA. The correlation coefficient, coefficient of determination, mean absolute error, and root mean squared error were used as the evaluation indices of this model, and the results were 0.9643, 0.9299, 5.251, and 6.422, respectively. The present study showed the same degree of correlation as those of related studies, demonstrating that age estimation can be performed for a wide range of ages with higher estimation accuracy.

16 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YAYusuke Asami
Yusuke Asami
TYTakaaki Yoshimura
Takaaki Yoshimura
KMKeisuke Manabe
Keisuke Manabe
TYTomonari Yamada
Tomonari Yamada
Hiroyuki SugimoriHiroyuki Sugimori
Hiroyuki Sugimori
Purpose: A deep learning technique was used to analyze the triceps surae muscle. The devised interpolation method was used to determine muscle’s volume and verify the usefulness of the method. Materials and Methods: Thirty-eight T1-weighted cross-sectional magnetic resonance images of the triceps of the lower leg were divided into three classes, i.e., gastrocnemius lateralis (GL), gastrocnemius medialis (GM), and soleus (SOL), and the regions of interest (ROIs) were manually defined. The supervised images were classified as per each patient. A total of 1199 images were prepared. Six different datasets separated patient-wise were prepared for K-fold cross-validation. A network model of the DeepLabv3+ was used for training. The images generated by the created model were divided as per each patient and classified into each muscle types. The model performance and the interpolation method were evaluated by calculating the Dice similarity coefficient (DSC) and error rates of the volume of the predicted and interpolated images, respectively. Results: The mean DSCs for the predicted images were >0.81 for GM and SOL and 0.71 for GL. The mean error rates for volume were approximately 11% for GL, SOL, and total error and 23% for GL. DSCs in the interpolated images were >0.8 for all muscles. The mean error rates of volume were <10% for GL, SOL, and total error and 18% for GM. There was no significant difference between the volumes obtained from the supervised images and interpolated images. Conclusions: Using the semantic segmentation of the deep learning technique, the triceps were detected with high accuracy and the interpolation method used in this study to find the volume was useful.

31 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KUKousuke Usui
Kousuke Usui
TYTakaaki Yoshimura
Takaaki Yoshimura
SIShota Ichikawa
Shota Ichikawa
Hiroyuki SugimoriHiroyuki Sugimori
Hiroyuki Sugimori
Although the widespread use of digital imaging has enabled real-time image display, images in chest X-ray examinations can be confirmed by the radiologist’s eyes. Considering the development of deep learning (DL) technology, its application will make it possible to immediately determine the need for a retake, which is expected to further improve examination throughput. In this study, we developed software for evaluating chest X-ray images to determine whether a repeat radiographic examination is necessary, based on the combined application of DL technologies, and evaluated its accuracy. The target population was 4809 chest images from a public database. Three classification models (CLMs) for lung field defects, obstacle shadows, and the location of obstacle shadows and a semantic segmentation model (SSM) for the lung field regions were developed using a fivefold cross validation. The CLM was evaluated using the overall accuracy in the confusion matrix, the SSM was evaluated using the mean intersection over union (mIoU), and the DL technology-combined software was evaluated using the total response time on this software (RT) per image for each model. The results of each CLM with respect to lung field defects, obstacle shadows, and obstacle shadow location were 89.8%, 91.7%, and 91.2%, respectively. The mIoU of the SSM was 0.920, and the software RT was 3.64 × 10−2 s. These results indicate that the software can immediately and accurately determine whether a chest image needs to be re-scanned.