Jyh Myng Zen

Jyh Myng Zen


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2003 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
JZJyh Myng Zen
Jyh Myng Zen
Senthil Kumar AnantharajanSenthil Kumar Anantharajan
Senthil Kumar Anantharajan
DTDong‐Mung Tsai
Dong‐Mung Tsai

30 January 2003 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
JZJyh Myng Zen
Jyh Myng Zen
SLShiou‐Ling Liou
Shiou‐Ling Liou
Senthil Kumar AnantharajanSenthil Kumar Anantharajan
Senthil Kumar Anantharajan
MHMung‐Seng Hsia
Mung‐Seng Hsia

25 May 2004 in Analytical Chemistry
Verified
Journal Article
Closed access
JZJyh Myng Zen
Jyh Myng Zen
CHCheng-Teng Hsu
Cheng-Teng Hsu
YHYi-Lan Hsu
Yi-Lan Hsu
JSJun-Wei Sue
Jun-Wei Sue
ECEric D. Conte
Eric D. Conte

28 February 2018 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
NTNatarajan Thiyagarajan
Natarajan Thiyagarajan
DJDamodar Janmanchi
Damodar Janmanchi
YTYi‐Fang Tsai
Yi‐Fang Tsai
WWWondemagegn Hailemichael Wanna
Wondemagegn Hailemichael Wanna
RRRavirala Ramu
Ravirala Ramu
SYSteve Sheng-Fa Yu
Steve Sheng-Fa Yu

17 August 2000 in The Analyst
Verified
Journal Article
Closed access
PDF file
JZJyh Myng Zen
Jyh Myng Zen
HCHsieh-Hsun Chung
Hsieh-Hsun Chung
Senthil Kumar AnantharajanSenthil Kumar Anantharajan
Senthil Kumar Anantharajan
A disposable copper-plated screen-printed carbon electrode (CuSPE) was developed for the determination of hydrogen peroxide by flow injection analysis (FIA) at ambient temperature without deoxygenation. Cyclic voltammetry on the CuSPE in pH 7.4 phosphate buffer solution showed the growth of CuO and Cu2O. A well-defined reduction signal corresponding to the mediation of CuO and Cu2O occurred in the presence of hydrogen peroxide. The mechanistic study revealed that the reduction is a coupled-chemical reaction mechanism with the operation of pseudo-first order kinetics with respect to the concentration of Cu2O. The calculated electrochemical rate constant (ke) from Laviron’s model is 13.7 s−1. Systematic investigations were made to optimize the experimental parameters for hydrogen peroxide detection by FIA. With a poised potential of −0.3 V versus Ag/AgCl and a flow rate of 2 ml min−1, the calibration curve was found to be linear up to 200 μM hydrogen peroxide with a detection limit of 0.97 μM (S/N = 3). The CuSPE is fairly stable for repetitive measurements.

21 July 2004 in The Analyst
Verified
Journal Article
Closed access
PDF file
JZJyh Myng Zen
Jyh Myng Zen
CHCheng-Teng Hsu
Cheng-Teng Hsu
Senthil Kumar AnantharajanSenthil Kumar Anantharajan
Senthil Kumar Anantharajan
HLHueih-Jing Lyuu
Hueih-Jing Lyuu
KLKer-Yun Lin
Ker-Yun Lin
A disposable copper nanoparticle-plated screen-printed carbon electrode (designated as Cun-SPE100-nm) provides a new material for the determination of native amino acids. All 20 underivatized amino acids can be sensitively determined at 0.0 V vs. Ag/AgCl in pH 8 phosphate buffer solution. The precisely controlled copper nanoparticles can boost up the CuIIO/CuI 2O redox signal on the working surface without any prior pretreatment procedure. The formation of a reversible 1:1 CuIIO–amino acid complex on the Cun-SPE100-nm was proposed to play a key role in the reaction mechanism. Stable detection responses were obtained for all amino acids by flow injection analysis with detection limits (S/N = 3) that lie in the range of 24 nM–2.7 µM. Selected amino acids from six representative chemical natures were separated by HPLC and detected at the Cun-SPE100-nm with promising results.