Cyril Breque

Cyril Breque

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2020 in Obesity Surgery
Verified
Journal Article
Closed access
PDF file
JDJ. Danion
J. Danion
GDG. Donatini
G. Donatini
CBCyril Breque
Cyril Breque
DOD. Oriot
D. Oriot
JRJ. P. Richer
J. P. Richer
JFJ. P. Faure
J. P. Faure

23 March 2017 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
PDF file
PBP. Bouget
P. Bouget
CBCyril Breque
Cyril Breque
JBJ. S. Beranger
J. S. Beranger
JFJ. P. Faure
J. P. Faure
FKF. Khiami
F. Khiami
TVT. Vendeuvre
T. Vendeuvre
Purpose and hypothesis: Patellar ligament rupture is a rare disabling pathology requiring a surgical ligament suture protected by a frame. The gold standard is the steel cable, but its rigidity and the necessity of a surgical re-intervention for its removal render it unsatisfactory. The objective of this paper is to quantify the mechanical protection provided by the terylene® in comparison with steel. Twenty-four knees of 12 fresh frozen cadaveric subjects were divided into 2 homogeneous groups (terylene and steel) of 12 knees (mean age = 69.3 years). Proximal ligament repair was performed according to a three-tunnel transosseous reinsertion technique. Mechanical tests were performed in flexion to simulate movement of the knee. The interligament gap and the amplitude angulation of the knee were measured by a system of extensometer and optical goniometer. Mechanical analysis permitted calculation of flexion amplitude for a ligament gap of 1 and 2 mm taking as initial angle the adjusting angle of pretension of the protection frame. Study of deformations of frames was performed. Statistical analysis was performed with a Wilcoxon Mann Whitney test. There is no significant difference in protection of the ligament suture between the “terylene” and “steel” groups. Mean flexion amplitudes (mΔF) show no significant differences between the 2 groups for a distension of the suture of 1 mm (m ΔF terylene1 = 4.74 °; mΔF steel1 = 5.91°; p = 0.198) and 2 mm (mΔF terylene2 = 8.71°; mΔF steel2 = 10.41°; p = 0.114). Elastic deformation of terylene was significantly greater than that of steel (p = 0.0004). Suture protection of the patellar ligament by a terylene wire is not significantly different from that provided by steel frame. The elastic properties of terylene and absence of a need for re intervention to secure its removal lead us towards its use in acute ruptures of the patellar ligament. The main limits involve the properties of the chain extenders with no contraction/muscle shortening and partial dehydration of tendons and ligaments and the mean age of 69.3 years. Level 5.

16 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TETerence Essomba
Terence Essomba
Juan SandovalJuan Sandoval
Juan Sandoval
Med amine LaribiMed amine Laribi
Med amine Laribi
CWChieh-Tsai Wu
Chieh-Tsai Wu
CBCyril Breque
Cyril Breque
JRJean-Pierre Richer
Jean-Pierre Richer
This paper deals with a robotic manipulator dedicated to craniotomy with a remote center of motion based on a Spherical Parallel Manipulator (SPM) architecture. The SPM is proposed to handle the drilling tool through the requested craniotomy Degrees of Freedom (DoF) with two rotations. The proposed architecture allows one degree of redundancy according to the total DoF. Thus, a first contribution of this work focuses on the experimental analysis of craniotomy surgery tasks. Secondly, its behavior is improved, taking advantage of the redundancy of the SPM using the spinning motion as a reconfiguration variable. The spinning angle modulation allows the reconfigurable manipulator to minimize its motor torques. A series of motion capture and force experimentations is performed for the analysis of the kinematic and force interaction characterizing Burr hole craniotomy procedures. Experimentations were carried out by a neurosurgeon on a human cadaver, ensuring highly realistic conditions.

Verified
Journal Article
Open access
PDF file
MCMarine Cau
Marine Cau
Juan SandovalJuan Sandoval
Juan Sandoval
AAAmael Arguel
Amael Arguel
CBCyril Breque
Cyril Breque
NHNathalie Huet
Nathalie Huet
Med amine LaribiMed amine Laribi
Med amine Laribi
Classical surgical education has to face both a forensic reality and a technical issue: to train a learner in more complex techniques in an increasingly short time. Moreover, surgical training is still based on an empirical hierarchical relationship in which learners must reproduce a sequence of actions in a situation of strong emotional pressure. However, the effectiveness of learning and its quality are linked to the emotional states in which learners find themselves. Among these emotions, epistemic confusion can be found that arises in complex learning situations where there is a cognitive imbalance related to the comprehension of the task, and which results from a rupture between the pre-established patterns of the learner and the new learning task. Although one knows that confusion can have a beneficial or a negative impact on learning, depending on whether it is well regulated or not, the factors that can influence it positively are still poorly understood. Thus, the objective of this experiment is to assess the impact of confusion on the learning of a surgical procedure in an augmented reality context and to determine if this impact varies according to the feedback given to the learners and according to the occurrence of disruptive events. Medical externs were recruited (N = 15) who were required to perform a suturing task on a simulator and whose performance was measured using a Motion Capture (MoCap) system. Even though the statistical analyzes did not allow a conclusion to be reached, the protocol already established makes it possible to consider a longer-term study that will allow (by increasing the number of sessions and the number of participants) more significant results to be obtained in order to develop new surgical learning protocols. This preliminary study opens a new field of research on the influence of epistemic emotions, and more particularly of confusion, which is likely to upset traditional surgical teaching, and is based on negative conditioning and strong emotions with negative valence as well as stress and coercion.

31 December 2022 in Surgical and Radiologic Anatomy
Verified
Journal Article
Closed access
PDF file
RBRobert Beya
Robert Beya
DJDanion Jérôme
Danion Jérôme
VTVendeuvre Tanguy
Vendeuvre Tanguy
NMNguyen My-Van
Nguyen My-Van
RARenault Arthur
Renault Arthur
FJFaure Jean-Pierre
Faure Jean-Pierre

22 February 2023 in Surgical and Radiologic Anatomy
Verified
Journal Article
Open access
PDF file
RBRobert Beya
Robert Beya
DJDanion Jérôme
Danion Jérôme
VTVendeuvre Tanguy
Vendeuvre Tanguy
NMNguyen My‑Van
Nguyen My‑Van
RARenault Arthur
Renault Arthur
FJFaure Jean‑Pierre
Faure Jean‑Pierre
In this article Author name first and last names are reversed, should be changed from "BEYA Robert" to "Robert BEYA".