Miranda Stavileci

Prof. Miranda Stavileci


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2015 in Medical Science Monitor Basic Research
Verified
Journal Article
Open access
PDF file
MSMiranda Stavileci
Miranda Stavileci
VHVeton Hoxha
Veton Hoxha
MGMehmet Omer Gorduysus
Mehmet Omer Gorduysus
ITIlkan Tatar
Ilkan Tatar
KLKjell Laperre
Kjell Laperre
EMEdmond Muhaxheri
Edmond Muhaxheri
BACKGROUND:Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files usi...

13 June 2013 in Medical Science Monitor Basic Research
Verified
Journal Article
Open access
MSMiranda Stavileci
Miranda Stavileci
VHVeton Hoxha
Veton Hoxha
MGMehmet Omer Gorduysus
Mehmet Omer Gorduysus
ITIlkan Tatar
Ilkan Tatar
KLKjell Laperre
Kjell Laperre
MBMerita Berisha
Merita Berisha
Root canal shaping without any procedural error is of the utmost preference. Therefore, the purpose of this study was to use micro-computed tomography to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files. Sixty extracted upper second premolars were selected and were divided into 2 groups of 30. Before preparation, all samples were scanned by micro-CT. Then, 30 teeth were prepared with stainless steel files and the remaining 30 with ProTaper rotary files. Canal transportation and centering ability before and after root canal shaping were assessed using micro-CT. The amount and direction of canal transportation and the centering ratio of each instrument were determined in the coronal, middle, and apical parts of the canal. The 2 groups were statistically compared using one-way ANOVA. ProTaper rotary files gave less transportation (p<0.001) and better centering ability (p<0.00001) compared with stainless steel files. The manual technique for preparation of root canals with stainless steel files produces more canal transportation, whereas rotary files remain more centered in the canal.

15 June 2022 in Medical Science Monitor Basic Research
Verified
Journal Article
Open access
PDF file
VVVioleta Vula
Violeta Vula
MSMiranda Stavileci
Miranda Stavileci
NANexhmije Ajeti
Nexhmije Ajeti
VVVegim Vula
Vegim Vula
AKAstrit Kuçi
Astrit Kuçi
KMKastriot Meqa
Kastriot Meqa
BACKGROUND A hermetic seal at the apical terminus is required for healthy periradicular tissue. Root canal obturation sealers that are used in endodontics are based on zinc oxide eugenol, calcium hydroxide, resins, glass ionomers, silicone, or bioceramics, but no optimal sealer material has been identified to date. Therefore, the aim of this in vitro study was to evaluate apical leakage after crown-down preparation and root canal obturation with Endomethasone N, glass ionomer cement, and EndoRez sealers. MATERIAL AND METHODS For this in vitro study, we tested 92 extracted human teeth, which were divided into 3 groups after a preparation technique and obturation with Endomethasone N sealer, glass ionomer cement, and EndoRez sealer in combination with Thermafil obturator. Apical leakage was evaluated and compared among the tested groups using a dye leakage method through a stereomicroscope. The values were measured from the apex to the coronal extent of dye penetration. For statistical analysis, the t test was used for comparison of the arithmetic averages of tested groups. RESULTS After preparation with rotary files, tested groups obturated with Thermafil obturator in combination with Endomethasone sealer showed higher average dye penetration than tested groups obturated with EndoRez and glass ionomer sealer. CONCLUSIONS Although all experimental groups showed dye leakage, the glass ionomer sealer in combination with Thermafil showed the least leakage, compared with EndoRez and Endomethason N.