HF Duan

Prof. HF Duan

Department of Civil and Environmental Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Journal of Environmental Management
Verified
Journal Article
Closed access
TDTianan Deng
Tianan Deng
Kwok-wing ChauKwok-wing Chau
Kwok-wing Chau
HDHF Duan
HF Duan

22 October 2020 in Journal of Water Supply: Research and Technology—AQUA
Verified
Journal Article
Closed access
PDF file
HDHF Duan
HF Duan
BPBin Pan
Bin Pan
MWManli Wang
Manli Wang
LCLu Chen
Lu Chen
FZFeifei Zheng
Feifei Zheng
YZYing Zhang
Ying Zhang
In the context of smart city development and rapid urbanization worldwide, urban water supply system (UWSS) has been of vital importance to this process. This paper presents a comprehensive review on the transient flow research for UWSS management. This review consists of two aspects as follows. The first aspect is about the development and progress of current transient theory, including transient flow models, unsteady friction and turbulence models, and numerical simulation methods. The other aspect is about the utilization and application of transient-based methods for effective UWSS diagnosis and management, including leakage, discrete and extended partial blockages, unknown branch, and other defects in water pipelines. A total of 228 publications have been reviewed and analyzed in this paper. In addition to the state-of-the-art progress and achievement of the research on transients, the advances and recommendations of future work in this field are also discussed for the development and management of next-generation smart UWSS in the paper.

11 June 2010 in Journal of Hydraulic Research
Verified
Journal Article
Closed access
HDHF Duan
HF Duan
MGMohamed Ghidaoui
Mohamed Ghidaoui
PLPedro J. Lee
Pedro J. Lee
YTYeou-Koung Tung
Yeou-Koung Tung
The current waterhammer models coupled with friction models cannot adequately represent the pressure wave attenuation observed in real-world pipe systems, because the pressure wave damping is affected by additional effects not accounted for. One such effect is pipe visco-elasticity from the material behaviour of pipe-wall to be investigated herein. The numerical results indicate that the pressure head attenuation attributable to unsteady friction is comparable to the visco-elastic effect during the initial transient stage, while the visco-elastic effect becomes dominant both in terms of damping and phase shift at later stages. An analytical analysis shows that the visco-elastic effect is more critical if the visco-elastic retardation time is less than the wave travel time along the entire pipeline length. In addition, it is demonstrated that the visco-elastic term in waterhammer models is wrongly referred to in the literature as energy dissipation instead of energy transfer between fluid and pipe-wall by the work done by the pressure force.

1 April 2011 in Journal of Hydraulic Research
Verified
Journal Article
Closed access
HDHF Duan
HF Duan
PLPedro J. Lee
Pedro J. Lee
MGMohamed S. Ghidaoui
Mohamed S. Ghidaoui
YTYeou-Koung Tung
Yeou-Koung Tung
This research investigates the applicability of the transient-based frequency-response function (FRF) method for detecting leaks in complex series pipelines. The behaviour of transient waves in these pipelines with internal series junctions indicates that junction reflections modify the system resonant frequencies but have a small effect on the leak-induced information contained within the system frequency responses. The analogous method previously developed for single pipelines is extended to complex series pipe systems by using the analytical transfer matrix method herein and the extended method is validated by two simple numerical experimental cases consisting of 3-series pipes and 10-series pipes, respectively. The applied results indicate that the extended FRF method can be applied to detect single and multiple leaks in complex series pipelines as long as the location and size of the resonant peaks of system frequency responses are accurately determined.

25 July 2016 in Water Resources Management
Verified
Journal Article
Closed access
PDF file
HDHF Duan
HF Duan
FLFei Li
Fei Li
HYHexiang Yan
Hexiang Yan

1 October 2013 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
Silvia MeniconiSilvia Meniconi
Silvia Meniconi
HDHF Duan
HF Duan
PLP. J. Lee
P. J. Lee
Bruno BrunoneBruno Brunone
Bruno Brunone
MGM. S. Ghidaoui
M. S. Ghidaoui
MFMarco Ferrante
Marco Ferrante
Partial blockages commonly exist in pressurized pipeline systems, and the rapid remediation of such faults is required to reduce the wastage of energy as well as to maintain the serviceability of the pipe network. Numerous transient test–based techniques (TTBT) have been developed for detecting pipe defects, with each technique providing different advantages. Two previously developed techniques—pressure signal analysis (PSA) and frequency response analysis (FRA)—are experimentally tested in this study on systems of different pipe material and characteristics. Each method is validated using the experimental data, and the results show that PSA is most accurate for locating the blockage while FRA is most accurate for determining the radial constriction and length of the blockage section. To take advantage of the different strengths of the techniques, a coupling of the two methods is proposed. Experimental application results reveal that both detection accuracy and calculation efficiency are improved ...