Walter Schumacher

Prof. Walter Schumacher

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FHFlorian Hans
Florian Hans
WSWalter Schumacher
Walter Schumacher
SCShih-Feng Chou
Shih-Feng Chou
XWXiongfei Wang
Xiongfei Wang
In recent years, the applicability of multifrequency proportional-resonant (PR) current controllers has been extensively explored. The analysis and controller design are typically performed by means of frequency response methods. In this context, the open-loop system's gain crossover frequency and the associated phase margin are mostly used as design parameters. However, those parameters are not well defined in applications with multifrequency PR controllers, where multiple 0 dB-crossings of the open-loop gain emerge. In contrast, it is shown that the system's gain margin can mostly be utilized as reliable stability measure. Furthermore, since each resonator introduces an unwanted phase lag to its higher neighbored resonator, the desired stability margin might not be achieved by 'conventional' controller designs or the system could even be destabilized. Hence, this paper reviews common analytic design guidelines for PR current controllers and extends them to controllers that implement multiple resonators in either a stationary- or a synchronous reference-frame. To achieve a good compromise between the stability margin and a small steady-state control error, a recursive adjustment procedure for the controller's integral gains is proposed. The 'plug-and-play' controller design is applied to a grid-connected voltage-source converter (VSC) and the theoretical findings are validated by computer simulations and experiments.

3 December 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
FHFlorian Hans
Florian Hans
WSWalter Schumacher
Walter Schumacher
SCShih-Feng Chou
Shih-Feng Chou
XWXiongfei Wang
Xiongfei Wang
Passivity-based analysis and controller design offer a promising approach to guarantee the stability of power systems. If all grid-connected components act strictly passive, critical oscillations cannot arise. Recent research established design guidelines for current-controlled voltage-source converters (VSCs) that allow obtaining a non-negative real part of the converter input admittance for a wide frequency range. In this paper, the findings are extended and generalized from a control engineering point of view. Utilizing passivity indices to quantify the degree of the input admittance's passivity, the current controller design is reviewed and assessed. Further, generic and necessary passivation design criteria are proposed and carried out exemplarily for passive as well as for active damping using voltage feed-forward filters. Finally, the theoretical findings are validated by experiments.

6 January 2017 in Machines
Verified
Journal Article
Open access
PDF file
CACarla Albrecht
Carla Albrecht
JKJan Klöck
Jan Klöck
OMOnno Martens
Onno Martens
WSWalter Schumacher
Walter Schumacher
This paper addresses the identification and correction of amplitude and offset errors in the sinusoidal outputs from incremental position encoders. Precise angular position measurement is of high importance in many position control applications. Manufacturing tolerances and noise from thermal and electromagnetic interference sources introduce systematic and random errors in the orthogonal sine cosine output line signals. Evaluation of these signals reproduces deviations in the measured angular position. This paper proposes two methods to identify and compensate for the influence of the systematic errors online without the necessity of a reference measurement during identification. The key component of the methods is a nonlinear estimator that exploits the orthogonality property of harmonic functions. The first method explains the basic idea with a scalar error model and operates continuously but exhibits an angular shift in direction of rotation during transients of the parameters, whereas the second method assumes an error model with error parameters as a function over one full revolution of the encoder. The latter updates the error function iteratively in subsequent revolutions.

Verified
Journal Article
Open access
PDF file
AKAxel Klein
Axel Klein
WSWalter Schumacher
Walter Schumacher
Operations in the Delta-Sigma ( Δ Σ ) domain are a broad field of research. In this article the main, focus is on applications in control systems, nevertheless the results are generally applicable for Δ Σ -signal processing ( Δ Σ SP) in other fields. As the bit-stream does not have an instantaneous value, algebraic operations cannot be executed directly. The first approaches were made in the 1980s based on small-scale integration logic chips by Kouvaras and by Lagoyannis. Further algebraic operations and other implementations were introduced by Zrilic, by Ng, by Bradshaw and by Homann. Other publications utilize complex networks and operations to achieve the desired algebraic operations. These presented operations can be divided into different operation classes by the based implementation idea. In this paper, the known algebraic operation classes are further developed and new operation classes are presented. All implementations are compared and evaluated. For linear operations in control applications, the introduced Bipolar Interpretation is best rated. It compensates for the signal offset of bipolar bit-streams and results in the best signal quality by mapping the logic values true and false of bit-stream to plus and minus one before the algebraic operation. The output of the algebraic operation is a multibit value, to achieve a bit-stream as output value a third step is taken. The result is modulated by a digital Δ Σ -modulator ( Δ Σ -M). For nonlinear operations the most universal implementation is also based on three steps. In the first stage, the bit-streams are processed with short sinc 3 filters, resulting in multibit values. This signal is processed by digital signal processing (DSP). The output stage is a Δ Σ -M. For some nonlinear algebraic operations there can be better solutions than DSP, like shown for limiting. In short, this paper gives a detailed overview about different Δ Σ SP classes for linear and nonlinear operations. Newly presented are the scaling with Bit-Stream Modification, the Bipolar Interpretation class, the nonlinear operation class based on digital signal processing (DSP), the modified multiplication based on Delta Adder and benchmarks of all presented operations.

1 January 2010
Verified
Book Chapter
Closed access
PDF file
SKSönke Kock
Sönke Kock
WSWalter Schumacher
Walter Schumacher

3 April 2018 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
PDF file
MWMalte Westerloh
Malte Westerloh
STSven Twenhövel
Sven Twenhövel
JKJuergen Koehler
Juergen Koehler
WSWalter Schumacher
Walter Schumacher
Battery electric vehicles (BEVs) are equipped with Mobile Air Conditioning systems (MACs) to ensure a comfortable cabin temperature in all climates and ambient conditions as well as the optional conditioning of the traction battery. An assessment of the global electrical energy consumption of various MACs has been derived, where the basis of the assessment procedure is the climate data GREEN-MAC-LCCP 2007 (Global Refrigerants Energy & Environmental - Mobile Air Condition - Life Cycle Climate Performance) and the improved LCCP2013 (Life Cycle Climate Performance. The percentage driving time during 6 AM and 24 PM is divided into six different temperature bins with the solar radiation and relative humidity for 211 cities distributed over Europe, North, Central, and South America, Asia, South West Pacific, and Africa. The energy consumption of the MACs is determined by a thermal vehicle simulation. In this work, four different MACs are simulated and compared. The MACs that are investigated are two conventional refrigeration cycles with PTC (Positive Thermal Coefficient, one with R-1234yf and the other with R-744 as the refrigerant, as well as two heat pump systems, one with R-134a and the other with R-744. Taking into account the number of vehicle registrations and the average distance traveled per city, the average energy consumption per kilometer, the annual energy consumption per car, and the necessary energy for a BEV fleet for heating and cooling is estimated at city, country, continent and world level.This study also deals with the optimization of mobile air conditioning systems based on the Evans-Perkins process. These systems are used for cooling the passenger compartment. Additionally, a reversible system can be used as heat pump system for providing passenger and battery heating. The required electrical energy for this process depends on the temperature difference in the system. The available heat sources are discussed as well as the control strategy and the optimization potential. Finally, a generic control structure for refrigeration cycles with the refrigerants R-744 and R-1234yf is presented, where the control structure depends on independent, gain-scheduled controllers. This results in a very flexible control structure. The R-744 heat pump system is an example of a moderately complex mobile air conditioning and heating system because of the increasing degree of freedom due to the temporary transcritical process control.