Patrycja Tymińska-Wójcik

Dr. Patrycja Tymińska-Wójcik

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
PTPatrycja Tymińska-Wójcik
Patrycja Tymińska-Wójcik
KZKatarzyna Zaborowska-Sapeta
Katarzyna Zaborowska-Sapeta
DJDaniel Janczak
Daniel Janczak
TGTomasz Gizewski
Tomasz Gizewski
This study presents a prototype of Intelligent Brace—the gold medal winner in the 68th edition of the International EUREKA 2019 Competition, in Valencia, Spain. It shows how to improve the effectiveness of a static orthopedic brace, with modern technology based on advanced electronic solutions. The research uses in-house-made thin-film graphene sensors, an electronic system with a microcontroller and derotating pads, a mobile application for Android system, and a remote database. The article presents a description of the real project, the system principle of operation, and the layout of the system elements in the orthosis. A prototype device was designed and built that was tested not only in laboratory conditions, but also during trials with the first patient. Approximately two months of data were collected and interpreted. The collected research results provided basic knowledge about the range of forces exerted by the brace on the patient’s body, as well as the regularity of wearing the orthosis by the patient and compliance with the doctor’s recommendations.

27 February 2026 in Children
Verified
Journal Article
Open access
PDF file
KZKatarzyna Zaborowska-Sapeta
Katarzyna Zaborowska-Sapeta
PTPatrycja Tymińska-Wójcik
Patrycja Tymińska-Wójcik
Anelise SonzaAnelise Sonza
Anelise Sonza
Marek KluszczyńskiMarek Kluszczyński
Marek Kluszczyński
ASAgnieszka Skowronska
Agnieszka Skowronska
Background: Children’s behavior and lifestyle are changing rapidly, potentially exceeding the capacity of physiological adaptation. Contemporary lifestyles may negatively affect spinal development and contribute to dysfunction and premature degeneration. Despite the increasing prevalence of postural changes, cervical spine disorders in adolescents remain under-researched. Methods: This narrative review is based on a comprehensive search of PubMed/MEDLINE and Scopus. The search strategy included a broad review of anatomical and biomechanical literature from the past 25 years and a focused review of studies from the last 15 years to reflect recent generational changes. Results: The immature spine has distinct structural and biomechanical characteristics that increase susceptibility to maladaptive responses to unbalanced forces. High screen time is associated with sedentary behavior and increased consumption of ultra-processed foods, which may affect metabolic health and musculoskeletal development. Childhood and adolescent obesity are increasingly prevalent and may influence spinal development, including through myosteatosis. Data on the consequences of cervical and lumbar lordosis loss in adolescents remain limited. Although degenerative spinal disorders are well recognized in adults, their identification in younger populations may be inadequate. Conclusions: Modern lifestyle factors pose a growing risk to children’s spinal health through complex interactions among behavioral, metabolic, and biomechanical mechanisms. The developing spine’s vulnerability and the coexistence of multiple, interrelated risk factors support the need for integrated preventive strategies rather than single-factor interventions. Future studies should focus on models capturing these interactions and their long-term consequences.

31 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
Michał LechMichał Lech
Michał Lech
Paweł WęgierekPaweł Węgierek
Paweł Węgierek
PTPatrycja Tymińska-Wójcik
Patrycja Tymińska-Wójcik
The paper presents a comparison of two methods for determining the burning time of an electric arc in a vacuum chamber: the classic oscilloscope method and the author’s own photographic analysis using an ultra-high-speed camera. A specially designed laboratory station enabled precise recording of electrical and optical parameters during switching operations conducted at different pressures in the discharge chamber. The photographic method consisted of a time-lapse analysis of the ignition and extinction of the arc using dedicated software to precisely determine its duration based on the recorded images. In total, five repeated measurements were performed for each pressure value. All the results were subjected to a detailed statistical analysis, including the determination of standard deviations and confidence intervals. The reported mean relative error for the new photographic method did not exceed 1.12%. The developed photographic method proved to be a reliable tool for assessing the duration of the arc, while also enabling a detailed analysis of the dynamics of arc channel development. Possible applications include laboratory testing and diagnostics of switching devices, especially where traditional measurement methods are difficult to apply.


17 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
PTPatrycja Tymińska-Wójcik
Patrycja Tymińska-Wójcik
KZKatarzyna Zaborowska-Sapeta
Katarzyna Zaborowska-Sapeta
TGTomasz Gizewski
Tomasz Gizewski
The increasing demand for personalized conservative treatment of idiopathic scoliosis (IS) highlights the need for objective and continuous monitoring of corrective forces during brace therapy. This study aims to evaluate the feasibility and clinical relevance of a smart orthopedic brace equipped with integrated force sensors for long-term biomechanical assessment. Three female patients with different types of idiopathic scoliosis were treated using a custom-designed thoracolumbosacral orthosis incorporating four flexible pressure sensors, enabling real-time and long-term recording of corrective forces at key anatomical locations. Sensor data were analyzed in relation to brace-wearing adherence, patient activity, and radiological outcomes assessed using Cobb angle measurements. The results demonstrated substantial variability in force distribution and wearing patterns among patients, which was associated with differences in treatment effectiveness. Higher and more stable corrective forces near curve apices were generally accompanied by improved radiological outcomes, whereas irregular brace use and uneven pressure distribution limited therapeutic effects. Long-term monitoring enabled identification of insufficient correction zones and adherence issues. In conclusion, the proposed sensor-based orthotic system provides clinically relevant information on force distribution and brace use, supporting individualized therapy optimization. These findings indicate that smart braces can enhance clinical decision-making and contribute to more effective and personalized scoliosis management.

30 September 2025 in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Verified
Journal Article
Open access
PDF file
PTPatrycja Tymińska-Wójcik
Patrycja Tymińska-Wójcik
Celem tego artykułu jest biomechaniczna analiza różnych typów ortez, ze szczególnym uwzględnieniem korzyści wynikających z zastosowania aktywnej ortezy z czujnikami. Pierwsza część artykułu skupia się na biomechanice ortezy pasywnej, która wykorzystuje stałe siły korekcyjne wywierane przez sztywne elementy gorsetu na ciało pacjenta. Omówiono zasady działania takich gorsetów, ich wpływ na ustawienie kręgosłupa oraz ograniczenia wynikające z ich statycznego charakteru. Druga część dotyczy ortez aktywnych, które integrują nowoczesne technologie, takie jak sensory, umożliwiające dynamiczne dostosowanie sił korekcyjnych do bieżącego stanu pacjenta. Zostały omówione dotychczasowe rozwiązania, które pozwalają na monitorowanie i adaptację działania gorsetu, co znacząco zwiększa efektywność leczenia. Ostatnia część artykułu skupia się na zaletach ortezy aktywnej w terapii skoliozy w porównaniu do tradycyjnych ortez pasywnych. Aktywne podejście terapeutyczne pozwala na dynamiczne dostosowywanie działania gorsetu do bieżących potrzeb pacjenta, co zwiększa komfort noszenia i efektywność leczenia. Wykorzystanie technologii umożliwia także bieżącą ocenę postępów terapii oraz lepsze dostosowanie sił korekcyjnych do indywidualnych cech anatomicznych i biomechanicznych pacjenta.