Background: Risk stratifying patients with cardiogenic shock (CS) is a major unmet need. The recently proposed Society for Cardiovascular Angiography and Interventions (SCAI) stages as an approach to identify patients at risk for in-hospital mortality remains under investigation. We studied the utility of the SCAI stages and further explored the impact of hemodynamic congestion on clinical outcomes. Methods: The CS Working Group registry includes patients with CS from 8 medical centers enrolled between 2016 and 2019. Patients were classified by the maximum SCAI stage (B–E) reached during their hospital stay according to drug and device utilization. In-hospital mortality was evaluated for association with SCAI stages and hemodynamic congestion. Results: Of the 1414 patients with CS, the majority were due to decompensated heart failure (50%) or myocardial infarction (MI; 35%). In-hospital mortality was 31% for the total cohort, but higher among patients with MI (41% versus 26%, MI versus heart failure, P <0.0001). Risk for in-hospital mortality was associated with increasing SCAI stage (odds ratio [95% CI], 3.25 [2.63–4.02]) in both MI and heart failure cohorts. Hemodynamic data was available in 1116 (79%) patients. Elevated biventricular filling pressures were common among patients with CS, and right atrial pressure was associated with increased mortality and higher SCAI Stage. Conclusions: Our findings support an association between the proposed SCAI staging system and in-hospital mortality among patient with heart failure and MI. We further identify that venous congestion is common and identifies patients with CS at high risk for in-hospital mortality. These findings provide may inform future management protocols and clinical studies.
20 July 2021 in Journal of the American Heart Association
Background: Cardiogenic shock (CS) is a heterogeneous syndrome with varied presentations and outcomes. We used a machine learning approach to test the hypothesis that patients with CS have distinct phenotypes at presentation, which are associated with unique clinical profiles and in‐hospital mortality. Methods and Results: We analyzed data from 1959 patients with CS from 2 international cohorts: CSWG (Cardiogenic Shock Working Group Registry) (myocardial infarction [CSWG‐MI; n=410] and acute‐on‐chronic heart failure [CSWG‐HF; n=480]) and the DRR (Danish Retroshock MI Registry) (n=1069). Clusters of patients with CS were identified in CSWG‐MI using the consensus k means algorithm and subsequently validated in CSWG‐HF and DRR. Patients in each phenotype were further categorized by their Society of Cardiovascular Angiography and Interventions staging. The machine learning algorithms revealed 3 distinct clusters in CS: "non‐congested (I)", "cardiorenal (II)," and "cardiometabolic (III)" shock. Among the 3 cohorts (CSWG‐MI versus DDR versus CSWG‐HF), in‐hospital mortality was 21% versus 28% versus 10%, 45% versus 40% versus 32%, and 55% versus 56% versus 52% for clusters I, II, and III, respectively. The "cardiometabolic shock" cluster had the highest risk of developing stage D or E shock as well as in‐hospital mortality among the phenotypes, regardless of cause. Despite baseline differences, each cluster showed reproducible demographic, metabolic, and hemodynamic profiles across the 3 cohorts. Conclusions: Using machine learning, we identified and validated 3 distinct CS phenotypes, with specific and reproducible associations with mortality. These phenotypes may allow for targeted patient enrollment in clinical trials and foster development of tailored treatment strategies in subsets of patients with CS.
The aim of this study was to prospectively evaluate the impact of blood pressure management on stroke rates in patients receiving the HeartWare HVAD System. The ENDURANCE trial demonstrated noninferiority of the HeartWare HVAD System versus control (HeartMate II) in patients with advanced heart failure ineligible for heart transplantation. However, stroke was more common in HVAD subjects. Post hoc analyses demonstrated increased mean arterial blood pressure as a significant independent risk factor for stroke. The ENDURANCE Supplemental Trial was a prospective, multicenter evaluation of 465 patients with advanced heart failure ineligible for transplantation, randomized 2:1 to HVAD (n = 308) or control (n = 157). The primary endpoint was the 12-month incidence of transient ischemic attack or stroke with residual deficit 24 weeks post-event. Secondary endpoints included the composite of freedom from death, disabling stroke, and need for device replacement or urgent transplantation, as well as comparisons of stroke or transient ischemic attack rates in HVAD cohorts in ENDURANCE Supplemental and ENDURANCE. The enhanced blood pressure protocol significantly reduced mean arterial blood pressure. The primary endpoint was not achieved (14.7% with HVAD vs. 12.1% with control, noninferiority [margin 6%] p = 0.14). However, the secondary composite endpoint demonstrated superiority of HVAD (76.1%) versus control (66.9%) (p = 0.04). The incidence of stroke in HVAD subjects was reduced 24.2% in ENDURANCE Supplemental compared with ENDURANCE (p = 0.10), and hemorrhagic cerebrovascular accident was reduced by 50.5% (p = 0.02). The ENDURANCE Supplemental Trial failed to demonstrate noninferiority of HVAD versus control regarding the pre-specified primary endpoint. However, the trial confirmed that BP management is associated with reduced stroke rates in HVAD subjects. HVAD subjects, relative to control subjects, more commonly achieved the composite endpoint (freedom from death, disabling stroke, and device replacement or urgent transplantation). (A Clinical Trial to Evaluate the HeartWare™ Ventricular Assist System [ENDURANCE SUPPLEMENTAL TRIAL] [DT2]; NCT01966458).
Background: The MOMENTUM 3 study (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) has demonstrated that the HeartMate 3 (HM3) pump is associated with reduced strokes compared with the HeartMate II (HMII) device. We now perform a comprehensive analysis of stroke events to evaluate their longitudinal occurrence, clinical correlates, patterns, and impact on outcome across the 2-year duration of support. Methods: MOMENTUM 3 is a randomized controlled trial of the HM3 centrifugal-flow pump versus the HMII axial-flow pump in patients with advanced heart failure, regardless of the intended goal of support (bridge to transplantation or destination therapy). Baseline and postimplantation clinical correlates of stroke events were assessed with multivariable analyses. Longitudinal patterns, including device association, type of stroke (hemorrhagic versus ischemic), changing severity of impairment assessed with the modified Rankin Scale (disabling [modified Rankin Scale score >3] versus nondisabling [modified Rankin Scale score ≤3]) over time, and association with outcome, were determined. Results: In 361 patients with the intended implant (189 HM3 and 172 HMII), 65 strokes (40 ischemic strokes and 25 hemorrhagic strokes) occurred in 52 patients at a median of 131 (range, 1–733) days. No difference in stroke rate was noted between 0 and 180 days of follow-up between devices. However, stroke incidence in the long-term period (181–730 days after left ventricular assist device) was 3.3 times lower for the HM3 group (HM3: 0.04 versus HMII: 0.13 events per patient-year; odds ratio, 0.23; 95% CI, 0.08–0.63; P =0.01). Treatment with the HM3 pump was the only independent predictor of lower stroke events. We found no direct association of blood pressure or antithrombotic regimens with observed stroke rates. A stroke event significantly lowered 2-year postimplantation survival regardless of subtype or initial severity of neurological impairment compared with patients without a stroke (43±12% for hemorrhagic stroke, 57±9% for ischemic stroke, 51±11% for disabling, and 51±11% for nondisabling compared with 85±2% 2-year survival for patients without stroke). Conclusions: The HM3 pump is associated with a marked reduction in stroke rates compared with the HMII device, with benefits observed in the long-term period (>6 months). The occurrence of stroke of any type (hemorrhagic and ischemic) or of any functional severity (disabling and nondisabling) is predictive of a poor 2-year clinical outcome. Clinical Trial Registration: URL: https://www.clinicaltrials.gov/ . Unique identifier: NCT02224755.
Background: Cardiogenic shock occurring in the setting of advanced heart failure (HF-CS) is increasingly common. However, recent studies have focused almost exclusively on acute myocardial infarction-related CS. We sought to define clinical, hemodynamic, metabolic, and treatment parameters associated with clinical outcomes among patients with HF-CS, using data from the Cardiogenic Shock Working Group registry. Methods: Patients with HF-CS were identified from the multicenter Cardiogenic Shock Working Group registry and divided into 3 outcome categories assessed at hospital discharge: mortality, heart replacement therapy (HRT: durable ventricular assist device or orthotopic heart transplant), or native heart survival. Clinical characteristics, hemodynamic, laboratory parameters, drug therapies, acute mechanical circulatory support device (AMCS) utilization, and Society of Cardiovascular Angiography and Intervention stages were compared across the 3 outcome cohorts. Results: Of the 712 patients with HF-CS identified, 180 (25.3%) died during their index admission, 277 (38.9%) underwent HRT (durable ventricular assist device or orthotopic heart transplant), and 255 (35.8%) experienced native heart survival without HRT. Patients who died had the highest right atrial pressure and heart rate and the lowest mean arterial pressure of the 3 outcome groups ( P 1 AMCS device had the highest in-hospital mortality rate irrespective of the number of vasoactive drugs used. Mortality increased with deteriorating Society of Cardiovascular Angiography and Intervention stages (stage B: 0%, stage C: 10.7%, stage D: 29.4%, stage E: 54.5%, 1-way ANOVA=1 AMCS device.