Woo-Suck Han

Prof. Dr. Woo-Suck Han

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
RVRahul Vellaparambil
Rahul Vellaparambil
WHWoo-Suck Han
Woo-Suck Han
PGPierluigi Di Giovanni
Pierluigi Di Giovanni
Stephane AvrilStephane Avril
Stephane Avril
With the rising popularity of endovascular aortic repair (EVAR) for aortic aneurysms and dissections, there is a crucial need for investigating the delayed appearance of post-EVAR complications such as stent-graft kinking, fracture and migration respectively. These complications have been noted to be influenced by the radial stiffness and bending flexibility attributes of stent-grafts. Auxetic designs with negative Poisson's ratio offer interesting advantages such as enhanced fracture toughness, superior indentation resistance and adaptive stiffness in response to intricate morphology for stenting applications over conventional stent designs. The objective of this study is to propose different auxetic stent candidates and to compare their mechanical performance with two conventional stent candidates for endovascular applications using numerical simulation through crimp/crushing tests for their radial stiffness and three-point bending/kinking tests for their flexibility, respectively. The results demonstrate that the novel hybrid auxetic designs (CRE and CSTAR) possess the best trade-off between radial stiffness and bending flexibility characteristics among all candidates for stent-graft applications.

21 January 2013 in Journal of Reinforced Plastics and Composites
Verified
Journal Article
Closed access
YJYeonhee Jung
Yeonhee Jung
SKSeung Jo Kim
Seung Jo Kim
WHWoo-Suck Han
Woo-Suck Han
Numerical simulation for resin transfer moulding manufacturing process is attempted using the extended finite element method combined with the level set method. The level set method is used to transport the resin flow front at each time step during the mould filling. Extended finite element method allows to obtaining a good numerical precision of the resin pressure near the resin flow front, where the gradient of the pressure could be discontinuous. The enriched shape functions of extended finite element method are derived using the level set values so as to correctly describe these shape functions with the resin flow front. In addition, the position of the resin flow front at each time step is calculated by an implicit characteristic Galerkin finite element method. Some examples are presented to validate our study in comparison with analytical or experimental results and to illustrate its industrial applications.

18 December 2023 in Cardiovascular Engineering and Technology
Verified
Journal Article
Open access
PDF file
RVRahul Vellaparambil
Rahul Vellaparambil
WHWoo-Suck Han
Woo-Suck Han
PGPierluigi Di Giovanni
Pierluigi Di Giovanni
Stephane AvrilStephane Avril
Stephane Avril
Purpose: Inappropriate stent-graft (SG) flexibility has been frequently associated with endovascular aortic repair (EVAR) complications such as endoleaks, kinks, and SG migration, especially in tortuous arteries. Stents derived from auxetic unit cells have shown some potential to address these issues as they offer an optimum trade-off between radial stiffness and bending flexibility. Methods: In this study, we utilized an established finite element (FE)-based approach to replicate the mechanical response of a SG iliac limb derived from auxetic unit cells in a virtual tortuous iliac aneurysm using a combination of a 180° U-bend and intraluminal pressurization. This study aimed to compare the mechanical performance (flexibility and durability) of SG limbs derived from auxetic unit cells and two commercial SG limbs (Z-stented SG and circular-stented SG models) in a virtual tortuous iliac aneurysm. Maximal graft strain and maximum stress in stents were employed as criteria to estimate the durability of SGs, whereas the maximal luminal reduction rate and the bending stiffness were used to assess the flexibility of the SGs. Results: SG limbs derived from auxetic unit cells demonstrated low luminal reduction (range 4–12%) with no kink, in contrast to Z-stented SG, which had a kink in its central area alongside a high luminal reduction (44%). Conclusions: SG limbs derived from auxetic unit cells show great promise for EVAR applications even at high angulations such as 180°, with acceptable levels of durability and flexibility.

14 August 2019
Verified
Book Chapter
Closed access
PDF file
RBRébecca Bonnaire
Rébecca Bonnaire
WHWoo-Suck Han
Woo-Suck Han
PCPaul Calmels
Paul Calmels
RCReynald Convert
Reynald Convert
JMJérôme Molimard
Jérôme Molimard

30 July 2014 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
RBR. Bonnaire
R. Bonnaire
WHWoo-Suck Han
Woo-Suck Han
Jérôme MolimardJérôme Molimard
Jérôme Molimard
PCP. Calmels
P. Calmels
CRConvert Reynald
Convert Reynald

31 August 2017 in Lecture Notes in Bioengineering
Verified
Book Chapter
Closed access
PDF file
BDBoris Dousteyssier
Boris Dousteyssier
JMJérôme Molimard
Jérôme Molimard
CHChafiaa Hamitouche
Chafiaa Hamitouche
WHWoo-Suck Han
Woo-Suck Han
ESEric Stindel
Eric Stindel