Ewa Niechwiej-Szwedo

Dr. Ewa Niechwiej-Szwedo


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2019 in Neural Plasticity
Verified
Journal Article
Open access
PDF file
ENEwa Niechwiej-Szwedo
Ewa Niechwiej-Szwedo
LCLinda Colpa
Linda Colpa
AWAgnes M. F. Wong
Agnes M. F. Wong
Amblyopia is a neurodevelopmental visual disorder arising from decorrelated binocular experience during the critical periods of development. The hallmark of amblyopia is reduced visual acuity and impairment in binocular vision. The consequences of amblyopia on various sensory and perceptual functions have been studied extensively over the past 50 years. Historically, relatively fewer studies examined the impact of amblyopia on visuomotor behaviours; however, research in this area has flourished over the past 10 years. Therefore, the aim of this review paper is to provide a comprehensive review of current knowledge about the effects of amblyopia on eye movements, upper limb reaching and grasping movements, as well as balance and gait. Accumulating evidence indicates that amblyopia is associated with considerable deficits in visuomotor behaviour during amblyopic eye viewing, as well as adaptations in behaviour during binocular and fellow eye viewing in adults and children. Importantly, due to amblyopia heterogeneity, visuomotor development in children and motor skill performance in adults may be significantly influenced by the etiology and clinical features, such as visual acuity and stereoacuity. Studies with larger cohorts of children and adults are needed to disentangle the unique contribution of these clinical characteristics to the development and performance of visuomotor behaviours.

12 March 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ENEwa Niechwiej-Szwedo
Ewa Niechwiej-Szwedo
DGDavid Gonzalez
David Gonzalez
MNMina Nouredanesh
Mina Nouredanesh
JTJames Tung
James Tung
Kinematic analysis of upper limb reaching provides insight into the central nervous system control of movements. Until recently, kinematic examination of motor control has been limited to studies conducted in traditional research laboratories because motion capture equipment used for data collection is not easily portable and expensive. A recently developed markerless system, the Leap Motion Controller (LMC), is a portable and inexpensive tracking device that allows recording of 3D hand and finger position. The main goal of this study was to assess the concurrent reliability and validity of the LMC as compared to the Optotrak, a criterion-standard motion capture system, for measures of temporal accuracy and peak velocity during the performance of upper limb, visually-guided movements. In experiment 1, 14 participants executed aiming movements to visual targets presented on a computer monitor. Bland-Altman analysis was conducted to assess the validity and limits of agreement for measures of temporal accuracy (movement time, duration of deceleration interval), peak velocity, and spatial accuracy (endpoint accuracy). In addition, a one-sample t-test was used to test the hypothesis that the error difference between measures obtained from Optotrak and LMC is zero. In experiment 2, 15 participants performed a Fitts’ type aiming task in order to assess whether the LMC is capable of assessing a well-known speed-accuracy trade-off relationship. Experiment 3 assessed the temporal coordination pattern during the performance of a sequence consisting of a reaching, grasping, and placement task in 15 participants. Results from the t-test showed that the error difference in temporal measures was significantly different from zero. Based on the results from the 3 experiments, the average temporal error in movement time was 40±44 ms, and the error in peak velocity was 0.024±0.103 m/s. The limits of agreement between the LMC and Optotrak for spatial accuracy measures ranged between 2–5 cm. Although the LMC system is a low-cost, highly portable system, which could facilitate collection of kinematic data outside of the traditional laboratory settings, the temporal and spatial errors may limit the use of the device in some settings.

1 November 2016 in Vision Research
Verified
Journal Article
Closed access
DGDavid A. Gonzalez
David A. Gonzalez
ENEwa Niechwiej-Szwedo
Ewa Niechwiej-Szwedo

1 August 2020 in Human Movement Science
Verified
Journal Article
Closed access
ENEwa Niechwiej-Szwedo
Ewa Niechwiej-Szwedo
GTGlenda Thai
Glenda Thai
LCLisa Christian
Lisa Christian

1 April 2016 in Human Movement Science
Verified
Journal Article
Closed access
FAFatimah Alramis
Fatimah Alramis
EREric Roy
Eric Roy
LCLisa W.T. Christian
Lisa W.T. Christian
ENEwa Niechwiej-Szwedo
Ewa Niechwiej-Szwedo

1 December 2017 in Human Movement Science
Verified
Journal Article
Closed access
ENEwa Niechwiej-Szwedo
Ewa Niechwiej-Szwedo
FAFatimah Alramis
Fatimah Alramis
LCLisa W.T. Christian
Lisa W.T. Christian