Background: The implementation of robotics in liver surgery offers several advantages compared to conventional open and laparoscopic techniques. One major advantage is the enhanced degree of freedom at the tip of the robotic tools compared to laparoscopic instruments. This enables excellent vessel control during inflow and outflow dissection of the liver. Parenchymal transection remains the most challenging part during robotic liver resection because currently available robotic instruments for parenchymal transection have several limitations and there is no standardized technique as of yet. We established a new strategy and share our experience. Methods: We present a novel technique for the transection of liver parenchyma during robotic surgery, using three devices (3D) simultaneously: monopolar scissors and bipolar Maryland forceps of the robot and laparoscopic-guided waterjet. We collected the perioperative data of twenty-eight patients who underwent this procedure for minor and major liver resections between February 2019 and December 2020 from the Magdeburg Registry of minimally invasive liver surgery (MD-MILS). Results: Twenty-eight patients underwent robotic-assisted 3D parenchyma dissection within the investigation period. Twelve cases of major and sixteen cases of minor hepatectomy for malignant and non-malignant cases were performed. Operative time for major liver resections (≥ 3 liver segments) was 381.7 (SD 80.6) min vs. 252.0 (70.4) min for minor resections (p < 0.01). Intraoperative measured blood loss was 495.8 (SD 508.8) ml for major and 256.3 (170.2) ml for minor liver resections (p = 0.090). The mean postoperative stay was 13.3 (SD 11.1) days for all cases. Liver surgery-related morbidity was 10.7%, no mortalities occurred. We achieved an R0 resection in all malignant cases. Conclusions: The 3D technique for parenchyma dissection in robotic liver surgery is a safe and feasible procedure. This novel method offers an advanced locally controlled preparation of intrahepatic vessels and bile ducts. The combination of precise extrahepatic vessel handling with the 3D technique of parenchyma dissection is a fundamental step forward to the standardization of robotic liver surgery for teaching purposing and the wider adoption of robotic hepatectomy into routine patient care.
Purpose: Minimally invasive liver surgery (MILS) is a feasible and safe procedure for benign and malignant tumors. There has been an ongoing debate on whether conventional laparoscopic liver resection (LLR) or robotic liver resection (RLR) is superior and if one approach should be favored over the other. We started using LLR in 2010, and introduced RLR in 2013. In the present paper, we report on our experiences with these two techniques as early adopters in Germany. Methods: The data of patients who underwent MILS between 2010 and 2020 were collected prospectively in the Magdeburg Registry for Minimally Invasive Liver Surgery (MD-MILS). A retrospective analysis was performed regarding patient demographics, tumor characteristics, and perioperative parameters. Results: We identified 155 patients fulfilling the inclusion criteria. Of these, 111 (71.6%) underwent LLR and 44 (29.4%) received RLR. After excluding cystic lesions, 113 cases were used for the analysis of perioperative parameters. Resected specimens were significantly bigger in the RLR vs. the LLR group (405 g vs. 169 g, p = 0.002); in addition, the tumor diameter was significantly larger in the RLR vs. the LLR group (5.6 cm vs. 3.7 cm, p = 0.001). Hence, the amount of major liver resections (three or more segments) was significantly higher in the RLR vs. the LLR group (39.0% vs. 16.7%, p = 0.005). The mean operative time was significantly longer in the RLR vs. the LLR group (331 min vs. 181 min, p = 0.0001). The postoperative hospital stay was significantly longer in the RLR vs. the LLR group (13.4 vs. LLR 8.7 days, p = 0.03). The R0 resection rate for solid tumors was higher in the RLR vs. the LLR group but without statistical significance (93.8% vs. 87.9%, p = 0.48). The postoperative morbidity ≥ Clavien-Dindo grade 3 was 5.6% in the LLR vs. 17.1% in the RLR group (p = 0.1). No patient died in the RLR but two patients (2.8%) died in the LLR group, 30 and 90 days after surgery (p = 0.53). Conclusion: Minimally invasive liver surgery is safe and feasible. Robotic and laparoscopic liver surgery shows similar and adequate perioperative oncological results for selected patients. RLR might be advantageous for more advanced and technically challenging procedures.
(1) Background: Here we report on a retrospective study of an international multicentric cohort after minimally invasive liver resection (SIMMILR) of colorectal liver metastases (CRLM) from six centers. (2) Methods: Resections were divided by the approach used: open liver resection (OLR), laparoscopic liver resection (LLR) and robotic liver resection (RLR). Patients with macrovascular invasion, more than three metastases measuring more than 3 cm or a solitary metastasis more than 5 cm were excluded, and any remaining heterogeneity found was further analyzed after propensity score matching (PSM) to decrease any potential bias. (3) Results: Prior to matching, 566 patients underwent OLR, 462 LLR and 36 RLR for CRLM. After PSM, 142 patients were in each group of the OLR vs. LLR group and 22 in the OLR vs. RLR and 21 in the LLR vs. RLR groups. Blood loss, hospital stay, and morbidity rates were all highly statistically significantly increased in the OLR compared to the LLR group, 636 mL vs. 353 mL, 9 vs. 5 days and 25% vs. 6%, respectively (p < 0.001). Only blood loss was significantly decreased when RLR was compared to OLR and LLR, 250 mL vs. 597 mL, and 224 mL vs. 778 mL, p < 0.008 and p < 0.04, respectively. (4) Conclusions: SIMMILR indicates that minimally invasive approaches for CRLM that follow the Milan criteria may have short term advantages. Notably, larger studies with long-term follow-up comparing robotic resections to both OLR and LLR are still needed.
Introduction: Study: International Multicentric Minimally Invasive Liver Resection for Colorectal Liver Metastases (SIMMILR-CRLM) was a propensity score matched (PSM) study that reported short-term outcomes of patients with CRLM who met the Milan criteria and underwent either open (OLR), laparoscopic (LLR) or robotic liver resection (RLR). This study, designated as SIMMILR-2, reports the long-term outcomes from that initial study, now referred to as SIMMILR-1. Methods: Data regarding neoadjuvant chemotherapeutic (NC) and neoadjuvant biological (NB) treatments received were collected, and Kaplan–Meier curves reporting the 5-year overall (OS) and recurrence-free survival (RFS) for OLR, LLR and RLR were created for patients who presented with synchronous lesions only, as there was insufficient follow-up for patients with metachronous lesions. Results: A total of 73% of patients received NC and 38% received NB in the OLR group compared to 70% and 28% in the LLR group, respectively (p = 0.5 and p = 0.08). A total of 82% of patients received NC and 40% received NB in the OLR group compared to 86% and 32% in the RLR group, respectively (p > 0.05). A total of 71% of patients received NC and 53% received NB in the LLR group compared to 71% and 47% in the RLR group, respectively (p > 0.05). OS at 5 years was 34.8% after OLR compared to 37.1% after LLR (p = 0.4), 34.3% after OLR compared to 46.9% after RLR (p = 0.4) and 30.3% after LLR compared to 46.9% after RLR (p = 0.9). RFS at 5 years was 12.1% after OLR compared to 20.7% after LLR (p = 0.6), 33.3% after OLR compared to 26.3% after RLR (p = 0.6) and 22.7% after LLR compared to 34.6% after RLR (p = 0.6). Conclusions: When comparing OLR, LLR and RLR, the OS and RFS were all similar after utilization of the Milan criteria and PSM. Biological agents tended to be utilized more in the OLR group when compared to the LLR group, suggesting that highly aggressive tumors are still managed through an open approach.
Introduction: Although the evidence is minimal, an abdominal binder is commonly prescribed after open incisional hernia repair (IHR) to reduce pain. This study aimed to investigate this common postoperative treatment. Methods: The ABIHR-II trial was a national prospective, randomized, multicenter non-AMG/MPG pilot study with two groups of patients (wearing an abdominal binder (AB) for 2 weeks during daytime vs. not wearing an AB following open IHR with the sublay technique). Patient enrollment took place from July 2020 to February 2022. The primary endpoint was pain at rest on the 14th postoperative day (POD) using the visual analog scale (VAS). The use of analgesics was not systematically recorded. Mixed-effects linear regression models were used. Results: A total of 51 individuals were recruited (25 women, 26 men; mean age 61.4 years; mean body mass index 30.65 kg/m2). The per-protocol analysis included 40 cases (AB group, n = 21; No-AB group, n = 19). Neither group showed a significant difference in terms of pain at rest, limited mobility, general well-being, and seroma formation and rate. Patients among the AB group had a significantly lower rate of surgical site infection (SSI) on the 14th POD (AB group 4.8% (n = 1) vs. No-AB group 27.8% (n = 5), p = 0.004). Conclusion: Wearing an AB did not have an impact on pain and seroma formation rate but it may reduce the rate of postoperative SSI within the first 14 days after surgery. Further trials are mandatory to confirm these findings.
Objectives Heat stroke is a serious condition that might lead from moderate organ impairment to multiple organ dysfunction syndrome. Appropriate diagnosis-finding, fast initiation of cooling and intensive care are key measures of the initial treatment. Scientific case report based on i) clinical experiences obtained in the clinical management of a particularly rare case and ii) selected references from the medical scientific literature. Case presentation We present a case of a young and healthy construction worker who suffered from an exertional heat stroke with a body core temperature exceeding 42 °C by previous several hour work at 35 °C ambient temperature. Heat stroke was associated with foudroyant, not reversible multiple organ dysfunction syndrome, in particular, early disturbed coagulation, microcirculatory, liver and respiratory failure, and subsequent fatal outcome despite immediate diagnosis-finding, rapid external cooling and expanded intensive care management. Conclusions Basic knowledge on an adequate diagnosis(-finding in time) and treatment of heat stroke is important for (almost each) physician in the summertime as well as is essential for the initiation of an appropriate management. Associated high morbidity and mortality rates indicate the need for implementation of standard operation protocols.