Shouying Li

Dr. Shouying Li


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2023 in Journal of Wind Engineering and Industrial Aerodynamics
Verified
Journal Article
Closed access
JLJiaqi Liu
Jiaqi Liu
Shouying LiShouying Li
Shouying Li
JLJing Luo
Jing Luo
ZCZhengqing Chen
Zhengqing Chen

29 June 2023 in Structures
Verified
Journal Article
Closed access
YLYafeng Li
Yafeng Li
Shouying LiShouying Li
Shouying Li
PTPing Tan
Ping Tan

13 October 2021 in Earthquake Engineering and Engineering Vibration
Verified
Journal Article
Closed access
PDF file
YLYafeng Li
Yafeng Li
Shouying LiShouying Li
Shouying Li
ZCZhengqing Chen
Zhengqing Chen

19 May 2024 in Ocean Engineering
Verified
Journal Article
Closed access
JLJiaqi Liu
Jiaqi Liu
Shouying LiShouying Li
Shouying Li
ZCZhengqing Chen
Zhengqing Chen

1 December 2021 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PDF file
MLMin Liu
Min Liu
Shouying LiShouying Li
Shouying Li
TWTeng Wu
Teng Wu
YLYafeng Li
Yafeng Li
HMHuachang Meng
Huachang Meng
ZCZhengqing Chen
Zhengqing Chen
The Noor III solar tower of the Ouarzazate Solar Power Station in Morocco is a very slender structure sensitive to wind excitations. Hence, tuned mass dampers (TMDs) were employed to reduce its wind-induced response. Finite-element modeling and wind-tunnel test results were employed to design the parameters of the TMD system. Four 10-t TMDs with eddy-current damping (EC-TMD) were selected for implementation (via a customized steel frame) at the top of the solar tower (i.e., inside the receiver). The effectiveness of the designed TMDs in controlling the tower was numerically studied under free vibration and forced vibration. Then, considering design and modeling errors and the possible need for on-site adjustments of EC-TMD parameters, pendulum-type EC-TMDs were fabricated. Dynamic properties of the tower were identified based on field measurements. With the installation and adjustment of the four designed EC-TMDs, the damping ratio of the Noor III solar tower was enhanced from 0.72% to 3.78%. Field measurements of tower vibrations under strong winds with/without participation of the EC-TMDs showed that significant mitigation of wind-induced response was effectively achieved by the TMDs with eddy-current damping. In addition, the on-site acceleration measured on the prototype tower was compared with the acceleration obtained for the scale model in a wind tunnel to highlight the significant Reynolds number effects on the prediction of the wind-induced response of the solar tower structure.

17 June 2020 in Journal of Vibration and Control
Verified
Journal Article
Closed access
PDF file
YLYafeng Li
Yafeng Li
Shouying LiShouying Li
Shouying Li
JWJianzhong Wang
Jianzhong Wang
ZCZhengqing Chen
Zhengqing Chen
A new type of damper combining eddy current damping with rack and gear, which can simultaneously export damping and inertial forces, is proposed. Eddy current damping with rack and gear is supposed to be installed between the building superstructure and foundation to mitigate the seismic response of the building. First, the concept of eddy current damping with rack and gear is introduced in detail and its apparent mass and equivalent damping coefficient are both theoretically investigated. Second, a prototype of eddy current damping with rack and gear is manufactured, and a series of tests on the prototype are carried out to verify its structural parameters. The experimental and theoretical results of the apparent mass of the prototype agree well with each other. The experimental result of the equivalent damping coefficient of the prototype is slightly lower than the numerical results obtained from COMSOL Multiphysics and its maximum relative differences are 11.3% and 13.6% for α = 0° and 45°, respectively. Third, detailed parametric studies on the damping force, including the effects of the thickness of the conductor plate, air gap, and number and location of permanent magnets, are conducted. The results show that the damping force keeps a linear relationship with velocity if it is lower than 0.15 m/s, and with the increase of the velocity, a strong nonlinear relationship between the damping force and the velocity is observed. The available maximum damping force can be increased by decreasing the thickness of the conductor plate and the air gap, increasing the number of permanent magnets. There is an optimal location about the permanent magnets for the available maximum damping force. In addition, the hysteretic curves of the eddy current damping with rack and gear obtained from the test indicate that the ability of energy dissipation is considerable.