To achieve a comprehensive understanding of a three-dimensional (3D) wind field and the speed-up phenomenon in a downburst wind flow over a 3D hilly terrain, a succession of laboratory tests utilizing 12 hill models with cosine-squared cross-section was conducted using a physical downburst simulator with a jet diameter of 0.6 m. By placing the models in the strong horizontal wind region and the strong vertical wind region, the corresponding wind profiles for both the horizontal and vertical velocities were measured. It was found that the wind flowed predominantly over the crest of the hill in the case of low hills, whereas wind flow around the hill body became increasingly pronounced as the hill height increased. In addition, the speed-up region, where the horizontal wind velocity exceeds the impinging jet velocity, was identified, and found to move from the crest to the two sides of the hill as the hill height increased. Accordingly, the most significant topographic multipliers of all locations on the hill might appear at the crest, the hill foot, or elsewhere, depending largely on the hill height. Among all cases, the maximum topographic multiplier was 1.12, and occurred at the ridge, while the ratio of hill height to jet height was 5/12. Additionally, empirical equations are presented to facilitate the determination of wind loads induced by a downburst flow over an isolated hill.
Corroded transmission towers, whose load-bearing capacities are lowered, are suffering from wind-induced damage. By simulating the member corrosion through section thinning, the structural dynamic finite element model of an angle-steel transmission tower with a corrosion depth of 0 mm to 1.4 mm was established using ANSYS/LS-DYNA software. The incremental dynamic analysis method was used to study the collapse mode of the tower under different degrees of corrosion, as well as the effects of corrosion on structural self-vibration characteristics, wind-induced member stress, and tower-top displacement. The results show that with the corrosion deepening, the first three vibration frequencies decrease, and the torsional mode becomes the first mode. When the corrosion depth is smaller, the overall structure failure occurs under strong wind. The failure starts at the most unfavorable oblique rod between the upper and middle cross arm, then expands to the rods under the lower cross arm. When the corrosion depth is larger, the overall structure failure occurs restrictedly between the upper and middle cross arm. Internal axial force and bending moment redistribution happen when corrosion deepens. Under the critical failure state, the oblique rods are always at a high stress level, while the stresses of the main rods decrease. Corrosion has a stronger impact on component strength and stability than on structural stiffness.
The modal analysis of a long-span transmission tower was carried out using a finite element method, and then its aeroelastic model was established by the discrete stiffness method for wind tunnel tests. The displacement and acceleration of the aeroelastic model were measured by a vision-based displacement measuring instrument and accelerometer, respectively. Also, the wind-induced responses of the tower were conducted by finite element calculation, with which the results of the wind tunnel tests are compared. The gust response factor was calculated and compared with those from the specifications and other studies. The results show that the vision-based displacement instrument can record well the vibration of the model tower in the wind tunnel. The acceleration of the tower is dominated by the first-order resonant response, whereas the displacement is dominated by the background response. The displacement and acceleration in the longitudinal and transversal directions are almost equal, indicating that the crosswind and along-wind responses are of the same magnitude. The displacement atop the tower obtained from the test after considering the Reynolds number correction almost coincided with that from the numerical simulation. The gust response factor of the tower obtained via wind tunnel tests is smaller than that of the codes and close to that found via finite element calculations.
A wind tunnel test was conducted to investigate the effects of parapets on the aerodynamic wind loads of roof-mounted solar arrays. The distribution of the mean wind pressure coefficient and the extreme wind pressure coefficient in the solar arrays were discussed in detail, and the results were compared with some national standards. Results show that the mean and extreme values of the wind pressure coefficient are larger at oblique wind angles. The presence of the parapet can reduce the mean and extreme area-averaged net pressure coefficients in some areas of the solar arrays, and both the most critical positive and negative shape factors reduce at the corner and outer rows while less change occurs at the inner zones. The experimental shape factors are much smaller compared to the values calculated by the standards. The guidelines for the design of wind pressure on roof-mounted solar arrays are very conservative, and more research is needed to make the standards applicable and complete.
An experimental study was conducted to investigate the aerodynamic loads on roof-mounted solar arrays. Four different parapet heights of 0 m, 0.9 m, 1.2 m, 1.5 m, and two tilt angles of 5° and 10°, are set to examine their effects on wind pressure coefficients. The statistics (means, standard deviations, skewness, kurtosis, maximum and minimum peaks) of wind pressure coefficients in different wind directions are exhibited and discussed in the current study. The results show that the oblique wind directions are critical for most measured locations, as the extreme of maximum and minimum peak pressure coefficients occur. The parapet can decrease wind loads on solar arrays, as expected. However, as the parapet is within a limited height in practice, it is not quite efficient to decrease wind loads despite the increasing of the parapet height. When the solar arrays are installed on the roof almost horizontally (tilt angle is less than 10°), the statistics of the aerodynamic load change a little with the decreasing of the tilt angle.
To investigate the coupling effects of wave–wind, wave–current, and wave–current–wind on a pile foundation of a marine structure, harbor basin tests on loads induced by single and combined action of wave, current, and wind were conducted. The time histories, power spectrums, and characteristic values of drag forces in the test conditions were compared. Then, the coupling coefficients were calculated based on the characteristic values to quantitively evaluate the coupling effects. The influence of natural vibration of the pile on the characteristic values and coupling effects were studied by comparing the test loads between rigid and elastic models. The results show that the shapes of power spectrums of drag forces and their peak frequencies in the wave-involved conditions are similar to the spectrum of incident wave, which means that the steady current and uniform wind cannot change the frequency distribution of incident random wave. Although the drag forces of rigid and elastic model under wave–wind, wave–current, and wave–current–wind are not the linear superposition of corresponding single field, the coupling effects among them are quite weak as the coupling coefficients are small. It is speculated that the weak wave–wind coupling effect may be because, firstly, the interaction of wave and wind is limited to the zone near the water surface, which is far less than the height of the model; secondly, the wave-induced load is dominant compared to wind and current. The loads in test conditions of elastic model are similar to the rigid model; for that, the model’s natural frequency is far away from the peak spectral frequency of incident wave, having little influence on the drag force.