Alessandro Maccarini

Dr. Alessandro Maccarini


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2023 in Energy
Verified
Journal Article
Closed access
AMAlessandro Maccarini
Alessandro Maccarini
ASArtem Sotnikov
Artem Sotnikov
TSTobias Sommer
Tobias Sommer
MWMichael Wetter
Michael Wetter
MSMatthias Sulzer
Matthias Sulzer
Alireza AfshariAlireza Afshari
Alireza Afshari

8 May 2023 in Energy and Buildings
Verified
Journal Article
Open access
MMMarco Marigo
Marco Marigo
AMAlessandro Maccarini
Alessandro Maccarini
AZAngelo Zarrella
Angelo Zarrella
AAAlireza Afshari
Alireza Afshari

11 April 2025 in Energy and Buildings
Verified
Journal Article
Open access
AEAlireza Etemad
Alireza Etemad
AMAlessandro Maccarini
Alessandro Maccarini
Donal P. FinnDonal P. Finn
Donal P. Finn
AAAlireza Afshari
Alireza Afshari
DSDivyanshu Sood
Divyanshu Sood
JOJames O’DOnnell
James O’DOnnell

22 December 2023 in Swedish Aerospace Conference, FT2025
Verified
Conference Paper
Open access
PDF file
AMAlessandro Maccarini
Alessandro Maccarini
MWMichael Wetter
Michael Wetter
DVDavide Varesano
Davide Varesano
MBMartin Bloemendal
Martin Bloemendal
Alireza AfshariAlireza Afshari
Alireza Afshari
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
This paper presents a low order aquifer thermal energy storage (ATES) model for simulation of combined subsurface and above-surface energy systems. The model is included in the Modelica IBPSA Library, which is a free open-source library with basic models for building and district energy and control systems. The model uses a lumped-component method, in which the transient conductive-convective heat and mass transfer equation is radially discretized. To verify the accuracy of the model, we present an intra-model comparison from a simulation test suite. Results show that the Modelica ATES model is in good agreement, with a normalized mean bias error for yearly variation of aquifer temperatures of 1.6×10−2 and 9×10−5 at 1 m and 10 m distance from the well.

13 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
HLHaider Latif
Haider Latif
SRSamira Rahnama
Samira Rahnama
AMAlessandro Maccarini
Alessandro Maccarini
CBCraig R. Bradshaw
Craig R. Bradshaw
GHGoran Hultmark
Goran Hultmark
Alireza AfshariAlireza Afshari
Alireza Afshari
Precision ventilation is developed to achieve thermal comfort for occupants in an office by creating micro-climate zones. The present study aims to achieve individual thermal comfort for occupants with different metabolic rates by using higher airspeeds for enhancing heat transfer. The variable jet interaction between two ACBs with JetCone adjustments cause higher velocity jets to reach different regions of the occupied zone. The colliding jets from the center of a thermal isolated room were moved towards different zones in an office configuration with a constant room temperature of 23 °C. This study was conducted for five different cases in a room divided into four zones according to occupants’ metabolic rates. The experimental and CFD results show that occupants facing symmetrical airflow distribution and with a constant 1.2 metabolic rate (Case 1) had a similar predicted mean vote (PMV) index. The zones with higher-metabolic-rate occupants, i.e., 1.4 met and 1.6 met in cases 2 and 3 were exposed to air velocities up to 0.4 and 0.5 m/s, respectively. In case 4, the air velocity in the single zone with 1.6 met occupants was raised to 0.6 m/s by targeted airflow distribution achieved by adjusting JetCones. These occupants with higher metabolic rates were kept thermally neutral, in the −0.5 to +0.5 PMV range, by pushing the high velocity colliding jets from the center towards them. In case 5, the results showed that precision ventilation can maintain the individual thermal comfort of up to three different zones (in the same office space) by exposing the occupants with metabolic rates of 1.2, 1.4, and 1.6 met to airspeeds of 0.15, 0.45, and 0.55 m/s, respectively.

2 April 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
HLHaider Latif
Haider Latif
SRSamira Rahnama
Samira Rahnama
AMAlessandro Maccarini
Alessandro Maccarini
GHGoran Hultmark
Goran Hultmark
PNPeter V. Nielsen
Peter V. Nielsen
Alireza AfshariAlireza Afshari
Alireza Afshari
Mixing ventilation systems effectively improves thermal comfort in open-spaces due to adequate turbulent mixing of the cold stream with ambient air. This study introduces the concept of precision ventilation for achieving local thermal comfort in a mixing ventilation system. This precision ventilation system provides asymmetrical airflows from an active chilled beam (ACB) to each of the office occupants. These ACBs provide air velocities with different magnitudes and directions. To achieve different magnitudes and directions, JetCones are used to vary the airflow in different parts of the ACB. The performance of the precision ventilation system was analyzed using full-scale laboratory experiments and computational fluid dynamic (CFD) simulations. The full-scale laboratory experiments were conducted in a 4.2 m × 3 m × 2.8 m (L × W × H) thermal isolated room with an open-plan dual desk-chair setup. The jet-cones in the ACB unit were adjusted to throw the required amount of flow to the occupants. The occupants had different metabolic rates of 1.2, 1.4, and 1.6 in a warm office space. The room set point temperatures varied between 23 and 26 °C. The experimental and CFD results show that occupants facing symmetrical airflow distribution and with a constant 1.2 metabolic rate had a similar PMV index. The occupants with 1.2, 1.4, and 1.6 metabolic rate were exposed to asymmetrical airflows, i.e., 30%, 58%, and 70% of the total airflow. Occupants with higher metabolic rates were kept thermally neutral, in the −0.5 to +0.5 PMV range, by increasing the air velocity and room temperature to 0.4 m/s and 25 °C, respectively.