With the continuous penetration and development of renewable energy power generation, distributed grids and microgrids are becoming increasingly important in power systems. In the distribution networks and microgrids, the grid impedance is comparatively large and cannot be ignored. Usually, the parallel compensation is used to improve the grid quality. In these three-phase four-wire power systems, analyzing the impedance characteristics of the grid-connected inverter is vital to carry out the small-signal stability analysis. Thus, it is vital to consider the influence of the zero-sequence component in addition to the positive-sequence component and the negative-sequence component when it comes to analyzing system stability. In this paper, the impedances of three-phase four-wire split capacitor inverter and three-phase four-leg inverter are established. Based on the achieved impedance, the similarities and differences between the impedances of three-phase four-wire split capacitor inverter and impedance of three-phase four-leg inverter are studied. The main difference is reflected in zero-sequence impedance. Additionally, the zero-sequence impedance characteristics and the dominating factors deciding the zero-sequence impedance are analyzed. Then, the stability of the system considering the grid impedance and impedance of three-phase four-wire inverter is investigated by separately considering the stability of the positive–negative-sequence component and the stability of the zero-sequence component. Several cases of small-signal instability caused by the positive–negative-sequence component or zero-sequence component are revealed. The experimental results validate the theoretical analysis.
With the continuous penetration and development of renewable energy power generation, the distributed grid and the microgrid are becoming increasingly important in modern power systems. In distribution networks and the microgrid, the grid impedance is comparatively large and cannot be ignored. Usually, the parallel compensation is used to improve the grid quality. In the grid with parallel compensation, the large phase angle difference between the impedance of the grid-connected inverter and the impedance of the grid at amplitude intersection will result in high frequency resonance (HFR). Because the inverter shows filter characteristics due to limited bandwidth of the controller, the parallel compensation grid, respectively, performs as the capacitance characteristic and inductance characteristic in different high frequency range. Compared with the three-phase, three-wire system, an additional zero-sequence path exists in the three-phase four-wire split capacitor inverter (TFSCI) system, so that the existing high frequency resonance suppression methods will be not effective. Since the zero-sequence component is neglected, HFR will also occur, in addition to the positive-sequence component and the negative-sequence component. Therefore, in order to suppress the high frequency resonance caused by positive-sequence, negative-sequence and zero-sequence components, an impedance reshaping strategy based on current feedback is proposed in this paper. This proposed method can reshape the amplitude and phase of the inverter impedance in a high frequency range without affecting the performance of the fundamental frequency control and ensure that the inverter contains a sufficient phase margin. Additionally, the proposed method can reshape the impedance of TFSCI within a wide frequency range, which makes it able to cope with the challenge of the parallel compensation degree change. Theoretical analysis and experiments verify the availability of the proposed control strategy.