Marcos Antônio Dórea Machado

Mr. Marcos Antônio Dórea Machado

Hospital São Rafael, Salvador, Bahia, Brazil
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
Mauro NamíasMauro Namías
Mauro Namías
TBT Bradshaw
T Bradshaw
VMV O Menezes
V O Menezes
Marcos Antônio Dórea MachadoMarcos Antônio Dórea Machado
Marcos Antônio Dórea Machado
RJR Jeraj
R Jeraj
Positron emission tomography (PET) imaging allows for measurement of activity concentrations of a given radiotracer in vivo . The quantitative capabilities of PET imaging are particularly important in the context of monitoring response to treatment, where quantitative changes in tracer uptake could be used as a biomarker of treatment response. Reconstruction algorithms and settings have a significant impact on PET quantification. In this work we introduce a novel harmonization methodology requiring only a simple cylindrical phantom and show that it can match the performance of more complex harmonization approaches based on phantoms with spherical inserts. Resolution and noise measurements from cylindrical phantoms are used to simulate the spherical inserts from NEMA image quality phantoms. An optimization algorithm was used to find the optimal smoothing filters for the simulated NEMA phantom images to identify those that best harmonized the PET scanners. Our methodology was tested on seven different PET models from two manufacturers installed at five institutions. Our methodology is able to predict contrast recovery coefficients (CRCs) from NEMA phantoms with errors within ±5.2% for CRCmax and ±3.7% for CRCmean (limits of agreement = 95%). After applying the proposed harmonization protocol, all the CRC values were within the tolerances from EANM. Quantitative harmonization in compliance with the EARL FDG-PET/CT accreditation program is achieved in a simpler way, without the need of NEMA phantoms. This may lead to simplified scanner harmonization workflows more accessible to smaller institutions.

14 January 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
NSNeilson Silveira de Souza
Neilson Silveira de Souza
TVThéo Cordeiro Veiga Vitório
Théo Cordeiro Veiga Vitório
RSRaphael Augusto de Souza
Raphael Augusto de Souza
Marcos Antônio Dórea MachadoMarcos Antônio Dórea Machado
Marcos Antônio Dórea Machado
HELMA PINCHEMEL COTRIMHELMA PINCHEMEL COTRIM
HELMA PINCHEMEL COTRIM
Background/Objectives: Artificial intelligence (AI) is an emerging technology for diagnosing liver fibrosis in Metabolic-Dysfunction-Associated Steatotic Liver Disease (MASLD), but a comprehensive synthesis of its performance is lacking. This systematic review (SR) aimed to evaluate the current evidence of AI models for diagnosing or staging liver fibrosis in patients with MASLD compared to conventional diagnostic tools. Methods: A comprehensive search was conducted in PubMed, Scopus, Web of Science, ScienceDirect, Embase, LILACS, IEEE Series, and Association for Computing Machinery (ACM). Primary studies applying AI to diagnose fibrosis in adults with MASLD were included. Risk of bias was assessed using the QUADAS-2 tool, and methodological reporting was evaluated according to the MINimum Information for Medical AI Reporting (MINIMAR) guideline. A narrative synthesis was performed, grouping studies by data type (clinical/laboratory vs. imaging) and summarizing diagnostic performance and clinical application. A frequency-based analysis was applied to identify the most recurrent predictive features, and an analysis of the AI architecture and application was reported. The review was registered in PROSPERO (CRD420251035919). Results: Twenty-one studies were included, encompassing 19,221 patients and 5237 images. Across studies, AI models consistently outperformed non-invasive scores such as Fibrosis-4 Index (FIB-4) and NAFLD Fibrosis Score (NFS). The most frequent predictive variables were identified. Despite an overall low risk of bias, methodological transparency and external validation were limited. Conclusions: AI is feasible for the non-invasive diagnosis of liver fibrosis in MASLD, demonstrating superior accuracy to standard clinical scores. Broader clinical application is limited by the lack of external validation and high heterogeneity among the studies. Prospective validation in diverse, multicenter cohorts is essential before AI can be integrated into routine clinical practice.

5 January 2024 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
Marcos Antônio Dórea MachadoMarcos Antônio Dórea Machado
Marcos Antônio Dórea Machado
TMThauan F. Moraes
Thauan F. Moraes
BABruno H.L. Anjos
Bruno H.L. Anjos
NANadja R.G. Alencar
Nadja R.G. Alencar
TCTien-Man C. Chang
Tien-Man C. Chang
ENEduardo Martins Netto
Eduardo Martins Netto

3 August 2018 in Journal of Nuclear Medicine Technology
Verified
Journal Article
Closed access
PDF file
Marcos Antônio Dórea MachadoMarcos Antônio Dórea Machado
Marcos Antônio Dórea Machado
VMVinícius O. Menezes
Vinícius O. Menezes
MNMauro Namías
Mauro Namías
NVNaiara S. Vieira
Naiara S. Vieira
CQCleiton C. Queiroz
Cleiton C. Queiroz
MOMércia L. Oliveira
Mércia L. Oliveira
Purpose: Oncological 18F-FDG PET/CT acquisition and reconstruction protocols need to be optimized for both quantitative and detection tasks. To date, most studies have focused on either quantification or noise, leading to quantitative harmonization guidelines or appropriate noise levels. We developed and evaluated protocols that provide harmonized quantitation with optimal amount of noise as a function of acquisition parameters and body mass. Methods: Multiple image acquisitions (N = 17) of the IEC/NEMA PET image quality phantom were performed with variable counting statistics. Phantom images were reconstructed with OSEM3D and PSF reconstructions for harmonized CRCmax quantification. The lowest counting statistics that resulted in compliance with EANM recommendations for CRCmax and CRCmax variability were used as optimization metrics. Image noise in the liver of 48 typical oncological 18F-FDG PET/CT studies was analysed with OSEM3D and PSF harmonized reconstructions. 164 additional 18F-FDG PET/CT reconstructed list mode images were also evaluated to derive analytical expressions that predict image quality and noise variability. Phantom to subject translational analysis was used to derive optimized acquisition and reconstruction protocols. Results: For harmonized quantitation levels, PSF reconstructions yielded decreased noise and lower CRCmax variability compared with regular OSEM3D reconstructions, suggesting they could enable a decreased activity regimen for matched performance. Conclusion: A PSF reconstruction with 7mm post-filter can provide harmonized quantification performance and acceptable image noise levels with injected activity, duration, and mass settings of 260 MBq.s/kg acquisition parameter at scan time. Similarly, the OSEM3D with 5mm post filter can provide similar performance with 401 MBq.s/kg.

7 March 2023 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
Marcos Antônio Dórea MachadoMarcos Antônio Dórea Machado
Marcos Antônio Dórea Machado
RSRonnyldo R. E. Silva
Ronnyldo R. E. Silva
Mauro NamíasMauro Namías
Mauro Namías
ALAndreia S. Lessa
Andreia S. Lessa
MNMargarida C. L. C. Neves
Margarida C. L. C. Neves
ENEduardo Martins Netto
Eduardo Martins Netto
Purpose To evaluate the classification performance of structured report features, radiomics, and machine learning (ML) models to differentiate between Coronavirus Disease 2019 (COVID-19) and other types of pneumonia using chest computed tomography (CT) scans. Methods Sixty-four COVID-19 subjects and 64 subjects with non-COVID-19 pneumonia were selected. The data was split into two independent cohorts: one for the structured report, radiomic feature selection and model building (n = 73), and another for model validation (n = 55). Physicians performed readings with and without machine learning support. The model's sensitivity and specificity were calculated, and inter-rater reliability was assessed using Cohen’s Kappa agreement coefficient. Results Physicians performed with mean sensitivity and specificity of 83.4 and 64.3%, respectively. When assisted with machine learning, the mean sensitivity and specificity increased to 87.1 and 91.1%, respectively. In addition, machine learning improved the inter-rater reliability from moderate to substantial. Conclusion Integrating structured reports and radiomics promises assisted classification of COVID-19 in CT chest scans.

21 June 2021 in Revista Brasileira de Física Médica
Verified
Journal Article
Open access
PDF file
Marcos Antônio Dórea MachadoMarcos Antônio Dórea Machado
Marcos Antônio Dórea Machado
JPJean Lucas Pereira Pita
Jean Lucas Pereira Pita
ENEduardo Martins Netto
Eduardo Martins Netto
We aimed to explore the variability of PET radiomic features for varying reconstruction methods and quantification settings. The IQ-NEMA phantom was scanned 5 times with a sphere to background F-18 concentration ratio of 10:1. The activity and the image duration were matched to result typical counting statistics for 18F-FDG oncologic examinations. The images were reconstructed with OSEM and PSF reconstructions, then 99 radiomic features were extracted using two discretization methods: fixed bin number (FBN = 16, 32 and 64 gray levels) and fixed bin width (FBW=0.25). This scheme resulted in a total of 1,188 features, classified as having low (<5.0%), intermediate (5-29.9%) or high (≥30%) variability. In general, FBW discretization yielded more stable features. A total of 499, 558 and 131 features had low, intermediate and high variability, respectively. First order features such as energy and entropy and textural features such as entropy (GLCM), long run emphasis and short run emphasis (GLRLM) were more likely to present low variability, regardless the reconstruction and discretization method. Other textural features such as large area emphasis (GLSZM), zone percentage (GLSZM) and complexity (NGTDM) had more frequently intermediate or high variability.These findings could facilitate features’ selection for further PET radiomic applications.