Refuge floors are fire safety requirements for tall buildings in many Asia-Oceania cities. However, there are concerns on the adequate provision of cross-ventilation and drencher system to openings on refuge floors. To review the existing situation, a survey of 44 building developments involving 51 blocks of both residential and non-residential tall buildings was conducted. A new fire safety parameter, i.e. the ratio of external wall openings areas to the nominal total wall areas of refuge floors (wall opening area ratio, or WOAR), was introduced to provide a quantitative measure in analysing fire safety level of tall buildings. To study how the ventilation provision is affected by WOAR, numerical simulations for the effect of natural ventilation on fire growth on the refuge floor were conducted by incorporating the wind data collected from the tallest building in Hong Kong. In the simulations, an office layout was adopted on both upper and lower floors for the sake of illustrating the possible smoke and heat spread from lower floor to upper floor (refuge floor). Finally, fire safety issues in relation to natural ventilation on fire in tall buildings were discussed. Suggestions in improving the fire safety design of tall buildings are proposed.
Timber buildings can now stand very tall using new products. As timber materials are expected to be easily ignitable, the fire hazard of timber is a concern. Charring of the timber surface would maintain structural stability, but would also be accompanied by smoke. Although treating timber products with fire retardants would delay the ignition time under low radiative heat flux, toxic combustion products and unburnt fuel would be emitted immediately upon burning. More smoke and higher toxic gas concentrations such as carbon monoxide would be given off upon burning some fire retardants under high flashover heat fluxes. Due to the fast upward movement of smoke under stack effect, spreading of toxic smoke in tall timber buildings would lead to a hazardous environment. Engineered timber consists of derivative timber products. New engineered timber products are manufactured with advanced technology and design, including cross-laminated-timber (CLT), laminated veneer lumber (LVL) and glue-laminated timber (Glulam). The fire behaviour of timber products has been studied for several decades. However, the smoke hazards of using new timber products in building construction should be monitored. The objective of this study is to inspire stakeholders in fire safety of timber buildings, inter alia smoke hazards, to use new timber products to build tall buildings.
To protect occupants from the dangers of fire in domestic buildings, the Fire Safety (Buildings) Ordinance (Cap 572) was enacted in 2002. The statute requires that the owners and occupiers of buildings used for domestic purposes where the first building plans were submitted during or before 1987 upgrade their fire safety provision to the 1994 standard. However, structural constraints in existing buildings prevent owners from installing heavy fire service installations (FSIs). Furthermore, installing FSIs in communal areas involves financial and property rights issues which may be insurmountable in nature. From this perspective, it is difficult for occupiers of these buildings, particularly the elderly and those on a low income, to enhance fire safety due to financial and technical burden and therefore they cannot enjoy the benefits of upgraded fire safety provision. Nevertheless, with reference to the proven effectiveness of an improvised sprinkler system (i.e. one which uses direct town main supplies and thus does not require the installation of water tanks and pumps) as an alternative to conventional sprinkler systems, this paper explores the technical feasibility of accepting an improvised hose reel (HR) system as an alternative to conventional HR systems.