Shih-Mo Yang

Shih-Mo Yang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SYShih-Mo Yang
Shih-Mo Yang
SYShih-Mo Yang
Shih-Mo Yang
Wenjun ZhangWenjun Zhang
Wenjun Zhang
YCYubao Cui
Yubao Cui
The early diagnosis of infectious diseases is critical because it can greatly increase recovery rates and prevent the spread of diseases such as COVID-19; however, in many areas with insufficient medical facilities, the timely detection of diseases is challenging. Conventional medical testing methods require specialized laboratory equipment and well-trained operators, limiting the applicability of these tests. Microfluidic point-of-care (POC) equipment can rapidly detect diseases at low cost. This technology could be used to detect diseases in underdeveloped areas to reduce the effects of disease and improve quality of life in these areas. This review details microfluidic POC equipment and its applications. First, the concept of microfluidic POC devices is discussed. We then describe applications of microfluidic POC devices for infectious diseases, cardiovascular diseases, tumors (cancer), and chronic diseases, and discuss the future incorporation of microfluidic POC devices into applications such as wearable devices and telemedicine. Finally, the review concludes by analyzing the present state of the microfluidic field, and suggestions are made. This review is intended to call attention to the status of disease treatment in underdeveloped areas and to encourage the researchers of microfluidics to develop standards for these devices.

16 April 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LYLei Yin
Lei Yin
GDGuanru Du
Guanru Du
BZBing Zhang
Bing Zhang
HZHongbo Zhang
Hongbo Zhang
RYRuixue Yin
Ruixue Yin
SYShih-Mo Yang
Shih-Mo Yang
The function and susceptibility of various drugs are tested with renal proximal tubular epithelial cells; yet, replicating the morphology and kidneys function using the currently available in vitro models remains difficult. To overcome this difficulty, in the study presented in this paper, a device and a three-layer microfluidic chip were developed, which provides a simulated environment for kidney organs. This device includes two parts: (1) microfluidic drug concentration gradient generator and (2) a flow-temperature controlled platform for culturing of kidney cells. In chip study, renal proximal tubular epithelial cells (RPTECs) and peritubular capillary endothelial cells (PCECs) were screened with the drugs to assess the drug-induced nephrotoxicity. Unlike cells cultured in petri dishes, cells cultured in the microfluidic device exhibited higher performance in terms of both cell growth and drug nephrotoxicity evaluation. It is worth mentioning that a significant decrease in cisplatin-induced nephrotoxicity was found because of the intervention of cimetidine in the microfluidic device. In conclusion, the different in the cell performance between the microfluidic device and the petri dishes demonstrates the physiological relevance of the nephrotoxicity screening technology along with the microfluidic device developed in this study. Furthermore, this technology can also facilitate the development of reliable kidney drugs and serve as a useful and efficient test-bed for further investigation of the drug nephrotoxicity evaluation.

1 May 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
SYShih-Mo Yang
Shih-Mo Yang
QLQiang Lin
Qiang Lin
HZHongbo Zhang
Hongbo Zhang
RYRuixue Yin
Ruixue Yin
Wenjun ZhangWenjun Zhang
Wenjun Zhang
YCYubao Cui
Yubao Cui
Digital ELISA is introduced as a novel platform with unique advantages for detecting multiple kinds of single-molecule in the sample. How to improve the sensitivity of detection is the direction of current related research. Here, we report an immunoassay method that applied electrokinetic effects to isolate the individual encoded beads and confine in micro-wells to improve the efficiency of cytokines detection simultaneously. The microfluidic design provided a non-uniform electric field to induce dielectrophoresis (DEP) force and to manipulate the beads. Two wavelengths of excitation light excited the encoded beads for simultaneous detection of reporters. The light was confined to the bottom slide via the principle of total internal reflection. Finally, the concentration of captured cytokines was obtained by picking up each bead from the image and then integrating the intensity of fluorescent light emitted from the reporters. The results demonstrated that the fill percentage of encoded beads was raised from 10-20% to 60-80% via DEP effect. By comparing the fluorescence color of the particle, itself and its surface, the concentration of four target cytokines, IL-2, IL-6, IL-10 and TNF-α, were calculated to the pg/ml level. The spike and recovery experiments verified the efficiency, more than 70% of the target molecules were captured. The reliability of our method was verified by flow cytometry as well. In conclusion, we expect the application of DEP can increase the sensitivity of digital ELISA for multiple rapid detection.

27 June 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SYShih-Mo Yang
Shih-Mo Yang
QBQingbo Bi
Qingbo Bi
WZWen Jun Zhang
Wen Jun Zhang
XCXiaochuan Cui
Xiaochuan Cui
YZYing Zhou
Ying Zhou
YCYubao Cui
Yubao Cui
The emerging single-molecule detection platform digital enzyme-linked immunosorbent assay (ELISA) can detect numerous proteins simultaneously at serum concentrations as low as picograms per milliliter.

17 February 2023 in Polymers
Verified
Journal Article
Open access
PDF file
ATAnthony Tony
Anthony Tony
Ildiko BadeaIldiko Badea
Ildiko Badea
CYChun Yang
Chun Yang
YLYuyi Liu
Yuyi Liu
KWKemin Wang
Kemin Wang
Wenjun ZhangWenjun Zhang
Wenjun Zhang
Polydimethylsiloxane (PDMS) is a widely used material for soft lithography and microfabrication. PDMS exhibits some promising properties suitable for building microfluidic devices; however, bonding PDMS to PDMS and PDMS to other materials for multilayer structures in microfluidic devices is still challenging due to the hydrophobic nature of the surface of PDMS. This paper presents a simple yet effective method to increase the bonding strength for PDMS-to-PDMS using isopropyl alcohol (IPA). The experiment was carried out to evaluate the bonding strength for both the natural-cured and the heat-cured PDMS layer. The results show the effectiveness of our approach in terms of the improved irreversible bonding strength, up to 3.060 MPa, for the natural-cured PDMS and 1.373 MPa for the heat-cured PDMS, while the best bonding strength with the existing method in literature is 1.9 MPa. The work is preliminary because the underlying mechanism is only speculative and open for future research.

29 May 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
CYChun Yang
Chun Yang
Di YinDi Yin
Di Yin
HZHongbo Zhang
Hongbo Zhang
Ildiko BadeaIldiko Badea
Ildiko Badea
SYShih-Mo Yang
Shih-Mo Yang
Wenjun ZhangWenjun Zhang
Wenjun Zhang
In recent years, cell migration assays (CMAs) have emerged as a tool to study the migration of cells along with their physiological responses under various stimuli, including both mechanical and bio-chemical properties. CMAs are a generic system in that they support various biological applications, such as wound healing assays. In this paper, we review the development of the CMA in the context of its application to wound healing assays. As such, the wound healing assay will be used to derive the requirements on CMAs. This paper will provide a comprehensive and critical review of the development of CMAs along with their application to wound healing assays. One salient feature of our methodology in this paper is the application of the so-called design thinking; namely we define the requirements of CMAs first and then take them as a benchmark for various developments of CMAs in the literature. The state-of-the-art CMAs are compared with this benchmark to derive the knowledge and technological gap with CMAs in the literature. We will also discuss future research directions for the CMA together with its application to wound healing assays.