Chiachung Chen

Dr. Chiachung Chen

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
HCHsuan-Yu Chen
Hsuan-Yu Chen
ACAndrew Chen
Andrew Chen
CCChiachung Chen
Chiachung Chen
Many types of thermometers have been developed to measure body temperature. Infrared thermometers (IRT) are fast, convenient and ease to use. Two types of infrared thermometers are uses to measure body temperature: tympanic and forehead. With the spread of COVID-19 coronavirus, forehead temperature measurement is used widely to screen people for the illness. The performance of this type of device and the criteria for screening are worth studying. This study evaluated the performance of two types of tympanic infrared thermometers and an industrial infrared thermometer. The results showed that these infrared thermometers provide good precision. A fixed offset between tympanic and forehead temperature were found. The measurement values for wrist temperature show significant offsets with the tympanic temperature and cannot be used to screen fevers. The standard operating procedure (SOP) for the measurement of body temperature using an infrared thermometer was proposed. The suggestion threshold for the forehead temperature is 36 °C for screening of fever. The body temperature of a person who is possibly ill is then measured using a tympanic infrared thermometer for the purpose of a double check.

21 July 2025 in Applied System Innovation
Verified
Journal Article
Open access
PDF file
HCHsuan-Yu Chen
Hsuan-Yu Chen
CCChiachung Chen
Chiachung Chen
Researchers conduct experiments to discover factors influencing the experimental subjects, so the experimental design is essential. The response surface methodology (RSM) is a special experimental design used to evaluate factors significantly affecting a process and determine the optimal conditions for different factors. The relationship between response values and influencing factors is mainly established using regression analysis techniques. These equations are then used to generate contour and surface response plots to provide researchers with further insights. The impact of regression techniques on response surface methodology (RSM) model building has not been studied in detail. This study uses complete regression techniques to analyze sixteen datasets from the literature on semiconductor manufacturing, steel materials, and nanomaterials. Whether each variable significantly affected the response value was assessed using backward elimination and a t-test. The complete regression techniques used in this study included considering the significant influencing variables of the model, testing for normality and constant variance, using predictive performance criteria, and examining influential data points. The results of this study revealed some problems with model building in RSM studies in the literature from three engineering fields, including the direct use of complete equations without statistical testing, deletion of variables with p-values above a preset value without further examination, existence of non-normality and non-constant variance conditions of the dataset without testing, and presence of some influential data points without examination. Researchers should strengthen training in regression techniques to enhance the RSM model-building process.

15 May 2015 in Sensors
Verified
Journal Article
Open access
PDF file
CCChiachung Chen
Chiachung Chen
Plant temperature can provide important physiological information for crop management. Non-contact measurement with an infrared thermometer is useful for detecting leaf temperatures. In this study, a novel technique was developed to measure leaf emissivity using an infrared thermometer with an infrared sensor and a thermocouple wire. The measured values were transformed into true temperatures by calibration equations to improve the measurement accuracy. The relationship between two kinds of measurement temperatures and setting emissivities was derived as a model for calculating of true emissivity. The emissivities of leaves of three crops were calculated by the mathematical equation developed in this study. The mean emissivities were 0.9809, 0.9783, 0.981 and 0.9848 for Phalaenopsis mature and new leaves and Paphiopedilum and Malabar chestnut leaves, respectively. Emissivity differed significantly between leaves of Malabar chestnut and the two orchids. The range of emissivities determined in this study was similar to that in the literature. The precision of the measurement is acceptable. The method developed in this study is a real-time, in situ technique and could be used for agricultural and forestry plants.

16 January 2019 in Foods
Verified
Journal Article
Open access
PDF file
CCChiachung Chen
Chiachung Chen
The water activity (Aw) and moisture content (MC) data of floral honey at five temperatures were determined using the Aw method and it was found that temperature significantly affected the Aw/MC data. The linear equation could be used to express the relationship between Aw and MC of honeys. The empirical regression equations between parameters and temperature were established. To evaluate the factors affecting the Aw/MC data, we used categorical tests of regression analysis to assess the effect of the correlation between Aw and MC of honey and examined the factors affecting the regression parameters. Six datasets from five countries were selected from the literature. The significance of the levels of qualitative categories was tested by t-test. The slope of the relationship between Aw and MC was affected by the state of honey (liquid and crystallized). The intercepts were significantly affected by honey type (flower or honeydew), harvesting year, geographical collection site, botanical source and other factors. The outliers in the datasets significantly affected the results. With modern regression analysis, useful information on the correlation between Aw and MC could be found. The results indicated that no universal linear equation for Aw and MC could be used. The Aw value could be used as a criterion for the honey industry; then, the MC of honey could be calculated by the specific linear equation between Aw and MC.

22 March 2006 in Accreditation and Quality Assurance
Verified
Journal Article
Closed access
PDF file
CCChiachung Chen
Chiachung Chen

4 April 2016 in Plant Cell, Tissue and Organ Culture (PCTOC)
Verified
Journal Article
Closed access
PDF file
CCChiachung Chen
Chiachung Chen