Estimating the recharge amount and investigate the hydrogeology of a given area is essential for sustainable management of groundwater resource. The objective of this study was to estimate groundwater recharge of Andassa catchment using chloride mass balance, base flow separation, soil moisture balance, water balance methods, and hydrogeologicalcharacteristics of the catchment. Meteorological, river discharge, pump test data together with well completion reports were used to estimate the recharge value and characterize the hydrogeology of the catchment. The average recharge value of the area is 307.3mm/year. There are tertiary and quaternary formations in the study area. The groundwater bearing formation of the area is grouped as: very low, low, moderate, high and very high aquifers based on transmissivity, yield of the borehole and springs. Very high productive aquifer in the low lands is recharged from regional groundwater flow and the middle elevated areas aquifer mainly shows local recharge.
Estimating the recharge amount of a given area is essential for sustainable management of groundwater resource. Andassa catchment which has area coverage of 609.68 square kilometer is located in north western Ethiopia. The area has flat, moderately slope and cliff topography. The rivers which have dendritic drainage pattern general flow south to north direction. Geological-geomorphological-structural feature suggest that the Andassa plain is a potential source of groundwater. The catchment has oligocene to miocene flood basalt with some deposit intercalation. There are tertiary and quaternary formations in the study area. The objective of this study was to estimate groundwater recharge of Andassa catchment using chloride mass balance, base flow separation, soil moisture balance, water balance methods were used to estimate the recharge value of the catchment. Meteorological, river discharge, pump tests, boreholes, springs and hand dug wells data together with well completion reports were used to estimate the recharge value. PET for the area was calculated using Penman gives annual potential evapo-transpiration value of 1335.26mm/year. Actual evapotranspiration (AET) for the area calculated using Turc and Thornthwaite Mather gives a value of 908.486mm/year and 1012.4 mm/year respectively. The recharge value is 370.68mm/y, 321.5 mm/y, 282.1mm/y and 255mm/year for base flow separation, soil moisture balance, water balance and chloride mass balance approaches respectively and the average recharge of the area is 307.3mm/year. The groundwater-bearing formation of the area is grouped as very low, low, moderate, high and very high aquifers based on transmissivity and yield of the borehole or springs. Very high productive aquifer in the low lands is recharged from regional groundwater flow and the middle elevated areas aquifer mainly shows local recharge.
The study area is found in Amhara Regional State, North Gondar Administrative Zone, Gondar town and surrounding Keble of river catchment. It’s total area coverage is 785 km2 with main lithologic units of lacustrine deposit, Middle Basalt (Aiba) and Upper basalt (Alajie).Numerical Groundwater Flow Modeling of the Megech River Catchment, Tana Sub Basin is conducted with the objective of simulating the groundwater flow system of the area and to evaluate the response of the hydrogeological system under different stress, so that the resulting consequence on the system can be estimated.The calibrated statistics of the model area with Mean Error (ME) of 4.8, Absolute Mean Error (AME) of 4.9, and Root Mean Square Error value of 6.8 (RMSE), which is an indicator of good calibration. The sensitive parameter of the model was identified during calibration process. Based on this, hydraulic conductivity and recharge is sensitive in RMSE than River Conductance values. The simulated water budget at steady state condition of Megech river catchment is analyzed. The simulated inflow of the model is 1.0703551E+06 m3/day which is equal to simulated outflow 1.0703559E+06 m3/day with difference -7.9617882E-01(-0.79617882) m3/day. The groundwater system of Megech Catchment total withdrawals of the well is 1.78853E+04m3/day. Scenario analysis was conduct in recharge decreasing and increasing of withdrawals rate. Keywords: calibration, water budget, simulation, Scenario, steady state, numerical groundwater flow modeling, sensitive, Tana sub basin, Megech River, groundwater withdrawal. DOI: 10.7176/JEES/12-6-01 Publication date:June 30th 2022