Background Electron beam melting (E-beam) is a new technology to produce 3-dimensional surface topographies for cementless orthopedic implants. Methods The friction coefficients of two newly developed E-beam produced surface topographies were in vitro compared with sandblasted E-beam and titanium plasma sprayed controls. Bone ingrowth (direct bone–implant contact) was determined by implanting the samples in the femoral condyles of 6 goats for a period of 6 weeks. Results Friction coefficients of the new structures were comparable to the titanium plasma sprayed control. The direct bone–implant contact was 23.9 and 24.5% for the new surface structures. Bone–implant contact of the sandblasted and titanium plasma sprayed control was 18.2 and 25.5%, respectively. Conclusions The frictional and bone ingrowth properties of the E-beam produced surface structures are similar to the plasma-sprayed control. However, since the maximal bone ingrowth had not been reached for the E-beam structures during the relatively short-term period, longer-term follow-up studies are needed to assess whether the E-beam structures lead to a better long-term performance than surfaces currently in use, such as titanium plasma spray coating.
BACKGROUND: It is assumed that high pore densities in flow diverters (FDs) are beneficial for intracranial aneurysm (IA) healing. However, various animal studies are not conclusive on the issue, suggesting that other factors are in play. One important factor might be wall apposition. OBJECTIVE: To (1) determine the relationship between FD pore density and aneurysm occlusion, and (2) determine the relationship between FD wall apposition and aneurysm occlusion. METHODS: Saccular aneurysms were microsurgically created in the aorta of 36 Wistar rats. Twelve rats received a low pore density FD (10 pores/mm2), 12 rats received a high pore density FD (23 pores/mm2), and the remaining 12 rats served as a control group. Six animals from each group were sacrificed 1 and 3 mo after surgery. We determined aneurysm occlusion, the number of struts not in contact with the aorta wall, and the average distance from malapposed struts to aorta wall through histology. RESULTS: No significant differences were found in aneurysm occlusion between the low pore density and high pore density groups (P > .05) after 1 and 3 mo of follow-up. The average number of malapposed struts was lower for the occluded aneurysm group (4.4 ± 1.9) compared to the nonoccluded aneurysm group (7.7 ± 2.6, P < .01). The average distance between malapposed struts and parent artery wall was lower for the occluded aneurysm group (33.9 μm ± 11.5 μm) than for the nonoccluded aneurysm group (48.7 μm ± 18.8 μm, P < .05). CONCLUSION: Wall apposition is more important than pore density for aneurysm occlusion.
One of the major problems facing the elderly spine is the occurrence of vertebral fractures due to low bone mass. Although typically attributed to osteoporosis, disc degeneration has also been suggested to play a role in vertebral fractures. Existing bone adaptation theories and simulations may explain the biomechanical pathway from a degenerated disc to an increased fracture risk. A finite element model of a lumbar segment was created and calibrated. Subsequently the disc properties were varied to represent either a healthy or degenerated disc and the resulting bone adaptation was simulated. Disc degeneration resulted in a shift of load from the nucleus to the annulus. The resulting bone adaptation led to a dramatically reduced density of the trabecular core and to an increased density in the vertebral walls. Degeneration of just the nucleus, and in particular the dehydration of the nucleus, resulted in most of this bone density change. Additional annulus degeneration had much less of an effect on the density values. The density decrease in the trabecular core as seen in this study matches clinical observations. Therefore, bone remodeling theories can assists in explaining the potential synergistic effects of disc degeneration and osteoporotis in the occurrence of vertebral fractures.
In vitro biomechanical study. To measure the effect that off-axis vertebral loading has on the stiffness and failure load of vertebrae. Adjacent level vertebral fractures not only are common in patients who received a vertebroplasty treatment but also occur in patients with conservatively treated wedge fractures. The wedge-like deformity, which is present in both groups, changes the spinal alignment. The load of vertebrae adjacent to the fractured vertebra will change from perpendicular to the endplate to a more shearing, off-axis, load. This change may induce a higher fracture risk for vertebrae adjacent to wedge-like deformed vertebrae. Twenty vertebrae, harvested from one osteopenic cadaver spine and three osteoporotic cadaver spines, were loaded until failure. The vertebrae were loaded either perpendicular to the upper endplate, representing vertebrae in a spine without wedge fractures (0° group, n = 10), or at an angle of 20°, representing vertebrae adjacent to a wedge fracture (20° groups, n = 10). Vertebral failure load and stiffness were the most important outcome measures. The failure load was significantly higher (P 5 0.028) when tested at 0° (2854 N, SD 5 622 N), compared with vertebrae tested at 20° (2162 N, SD 5 670 N). Vertebrae were also significantly stiffer (P, 0.001) when tested at 0° (4017 N/mm, SD 5 970 N/mm) than those tested at 20° (2478 N/mm, SD 5 453 N/mm). The failure load of osteopenic/osteoporotic vertebrae was 24% lower under off-axis loads (20°) than under axial loads (0°). This study may lead to a better understanding of the etiology of adjacent vertebral fractures after wedge-like deformities and demonstrates the importance of height reconstruction of wedge fractures in order to normalize the loading conditions on adjacent vertebrae.
9 December 2022 in Tissue Engineering Part B: Reviews
The large number of animal models used in spinal cord injury (SCI) research complicates the objective selection of the most appropriate model to investigate the efficacy of biomaterial-based therapies. This systematic review aims to identify a list of relevant animal models of SCI by evaluating the confirmation of SCI and animal survival in all published SCI models used in biomaterials research up until April 2021. A search in PubMed and Embase based on “spinal cord injury,” “animal models,” and “biomaterials” yielded 4606 papers, 393 of which were further evaluated. A total of 404 individual animal experiments were identified based on type of SCI, level of SCI, and the sex, species, and strain of the animals used. Finally, a total of 149 unique animal models were comparatively evaluated, which led to the generation of an evidence-based list of well-documented mid-thoracic rat models of SCI. These models were used most often, clearly confirmed SCI, and had relatively high survival rates, and therefore could serve as a future starting point for studying novel biomaterial-based therapies for SCI. Furthermore, the review discusses (1) the possible risk of bias in SCI animal models, (2) the difficulty in replication of such experiments due to frequent poor reporting of the methods and results, and (3) the clinical relevance of the currently utilized models. Systematic review registration: The study was prospectively registered in PROSPERO, registration number CRD42019141162. Impact statement Studies on biomaterial-based therapies within the field of spinal cord injury (SCI) research show a large inconsistency concerning the selection of animal models. This review goes beyond summarizing the existing gaps between experimental and clinical SCI by systematically evaluating all animal models used within this field. The models identified by this work were used most often, clearly confirmed SCI, and had a relatively high survival rate. This evidence-based list of well-documented animal models will serve as a practical guideline in future research on innovative biomaterial-based therapies for SCI.
Adjacent level vertebral fractures are common in patients with osteoporotic wedge fractures, but can theoretically be prevented with prophylactic vertebroplasty. Previous tests on prophylactic vertebroplasties have been performed under axial loading, while in vivo changes in spinal alignment likely cause off-axis loads. In this study we determined whether prophylactic vertebroplasty can also reduce the fracture risk under off-axis loads. In a previous study, we tested vertebral bodies that were loaded axially or 20° off-axis representing vertebrae in an unfractured spine or vertebrae adjacent to a wedge fracture, respectively. In the current study, vertebral failure load and stiffness of our previously tested vertebral bodies were compared to those of a new group of vertebral bodies that were filled with bone cement and then loaded 20° off-axis. These vertebral bodies represented adjacent-level vertebrae with prophylactic bone cement filling. Prophylactic augmentation resulted in failure loads that were comparable to those of the 0° group, and 32% greater than the failure loads of the 20° group. The stiffness of the prophylacticly augmented vertebrae was 21% lower than that of the 0° group, but 27% higher than that of the 20° group. We conclude that prophylactic augmentation can decrease the fracture risk in a malaligned, osteoporotic vertebra. Whether this is enough to actually prevent additional vertebral fractures in vivo remains subject of further study.