Francisco-J Renero-C

Dr. Francisco-J Renero-C

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
NHNatiely H
Natiely H
DDDaniela Diaz-Alonso
Daniela Diaz-Alonso
FRFrancisco-J Renero-C
Francisco-J Renero-C
NVNoé Villa-Villaseñor
Noé Villa-Villaseñor
WCWilfrido Calleja-Arriaga
Wilfrido Calleja-Arriaga
This paper reports the novel design of a touch mode capacitive pressure sensor (TMCPS) system with a wireless approach for a full-range continuous monitoring of ventricular pressure. The system consists of two modules: an implantable set and an external reading device. The implantable set, restricted to a 2 × 2 cm2 area, consists of a TMCPS array connected with a dual-layer coil, for making a reliable resonant circuit for communication with the external device. The capacitive array is modelled considering the small deflection regime for achieving a dynamic and full 5–300 mmHg pressure range. In this design, the two inductive-coupled modules are calculated considering proper electromagnetic alignment, based on two planar coils and considering the following: 13.56 MHz frequency to avoid tissue damage and three types of biological tissue as core (skin, fat and muscle). The system was validated with the Comsol Multiphysics and CoventorWare softwares; showing a 90% power transmission efficiency at a 3.5 cm distance between coils. The implantable module includes aluminum- and polyimide-based devices, which allows ergonomic, robust, reproducible, and technologically feasible integrated sensors. In addition, the module shows a simplified and low cost design approach based on PolyMEMS INAOE® technology, featured by low-temperature processing.

1 January 2017 in Diabetic Foot & Ankle
Verified
Journal Article
Open access
FRFrancisco-J Renero-C
Francisco-J Renero-C
Background: Thermoregulation is a complex autonomic process to keep or to dissipate heat in the human body. Methods: In this work, by means of the thermogram of the plantar skin, the thermoregulation of healthy individuals, overweight-obese, and diabetic is discussed. Results: The thermograms of the plantar skin, for the healthy individuals, are: (1) symmetrical, the temperature distribution of the right foot being a mirror image of that of the left foot ; (2) the thermograms of women, on average, are 3°C colder than those of the men; and (3) the temperature distributions decrease distally from the medial longitudinal arch. The plantar skin thermograms of overweight-obese individuals show: (1) increased average temperature of both feet and for both genders; (2) no symmetry between the left and right feet thermograms; and (3) the temperature distribution is still decreasing from the medial longitudinal arch to the periphery of the foot. However, the standard deviation, for each averaged temperature of the angiosomes, shows greater uncertainty. Most thermograms of diabetic individuals show temperature increase on the plantar skin, and are mostly symmetric between left and right feet. Conclusions: An asymmetric thermogram of the plantar skin of diabetic individuals, where one foot is hotter than the other, may mean that the coldest foot is losing the capacity to communicate properly with the central nervous system and/or that vasoconstriction/vasodilatation is having problems in regulating the passing of blood through the vessels. Thus, the asymmetric thermograms of diabetic patients, and particularly those coldest regions of foot are of interest, because of the reduction of the local autonomic sensing and the lack of achieving properly the passing of the blood.

30 January 2018 in Diabetic Foot & Ankle
Verified
Journal Article
Open access
FRFrancisco-J Renero-C
Francisco-J Renero-C
Background: One of the complications of the diabetes mellitus is the amputation of the lower limbs. This complication may be developed after an insidious ulcer, that may be raised by the peripheral neuropathy or the ischaemic limb, and that the ulcer get infected. That is, to develop an ulcer, in the diabetic patient, three factors should be taken into the account, the autonomic nervous system, the blood supply and the inmune system. Methods: In this work, the thermogram is used to identify regions on the plantar skin with blood supply deficiencies and the behaviour of the thermoregulation process. Within the thermogram of the plantar skin, it can be identify local regions with low and high temperatures that corresponds to ischemic or inflammatory process on that part of the skin. Results: The findings within the 186 thermograms of diabetic patients, obtained from three hospitals and from INAOE facilities, showed, first, the thermograms of the plantar skin of two diabetic patients, acquired in two different times show that the temperature distribution and the average temperatures, vary slightly for a period of weeks. Second, the thermograms of two patients, who both developed insidious ulcers which evolved favourable, demonstrated the importance of the immune system and the drug therapy. These patients are, one who has a Charcot foot, and in the second one, the patient had loss the sensibility of the feet. Finally, the thermograms of two patients, showing abrupt temperature change within small regions in the plantar skin, are discussed. Conclusion: A diabetic patient, with an asymmetric thermogram, as physiological interpretation of the thermoregulation, may indicate a decrease of the blood supply, which may be corroborated by vascular ultrasound. The regions of abrupt temperature change, cold or hot spots, may correspond to ischaemic or inflammatory processes.

1 December 2006 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
CSCésar Santiago
César Santiago
APArllene M. Pérez
Arllene M. Pérez
FRFrancisco-J Renero-C
Francisco-J Renero-C
CZCarlos Zuñiga
Carlos Zuñiga
This paper presents a study of the optical properties of amorphous hydrogenated silicon nitride (a-Si3N4:H) films under deposition temperature influence. The films were deposited by low-frequency plasma-enhanced chemical vapor deposition at temperatures of 200, 300, and 400°C and 0.6-Torr pressure. The mixture gases were silane (SiH4), ammonia (NH3), and hydrogen (H2). The optical properties of the films samples were obtained by means of the transmittance spectra and from spectroellipsometry measurements. Then, the optical parameters of the films were determined using the Swanepoel, Cauchy, and Sellmeier models. The refractive index dispersion curves were well fitted with both the Cauchy and the Sellmeier theoretical model. The equivalence between the parameters that characterize the two models is established.

10 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
NHNatiely H
Natiely H
NVNoé Villa-Villaseñor
Noé Villa-Villaseñor
FRFrancisco-J Renero-C
Francisco-J Renero-C
DDDaniela Diaz-Alonso
Daniela Diaz-Alonso
WCWilfrido Calleja-Arriaga
Wilfrido Calleja-Arriaga
In this paper, an alternative strategy for the design of a bidirectional inductive power transfer (IPT) module, intended for the continuous monitoring of cardiac pressure, is presented. This new integrated implantable medical device (IMD) was designed including a precise ventricular pressure sensor, where the available implanting room is restricted to a 1.8 × 1.8 cm2 area. This work considers a robust magnetic coupling between an external reading coil and the implantable module: a three-dimensional inductor and a touch mode capacitive pressure sensor (TMCPS) set. In this approach, the coupling modules were modelled as RCL circuits tuned at a 13.56 MHz frequency. The analytical design was validated by means of Comsol Multiphysics, CoventorWare, and ANSYS HFSS software tools. A power transmission efficiency (PTE) of 94% was achieved through a 3.5 cm-thick biological tissue, based on high magnitudes for the inductance (L) and quality factor (Q) components. A specific absorption rate (SAR) of less than 1.6 W/Kg was attained, which suggests that this IPT system can be implemented in a safe way, according to IEEE C95.1 safety guidelines. The set of inductor and capacitor integrated arrays were designed over a very thin polyimide film, where the 3D coil was 18 mm in diameter and approximately 50% reduced in size, considering any conventional counterpart. Finally, this new approach for the IMD was under development using low-cost thin film manufacturing technologies for flexible electronics. Meanwhile, as an alternative test, this novel system was fabricated using a discrete printed circuit board (PCB) approach, where preliminary electromagnetic characterization demonstrates the viability of this bidirectional IPT design.

1 April 2005 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
APArllene M. Pe´rez
Arllene M. Pe´rez
CZCarlos Zun˜iga
Carlos Zun˜iga
FRFrancisco-J Renero-C
Francisco-J Renero-C
ATAlfonso Torres
Alfonso Torres
Amorphous silicon germanium (a-Si1−xGex) thin films are prepared by low-frequency plasma-enhanced chemical vapor deposition (LF PECVD) on glass substrates, from SiH4+GeF4 and SiH4+GeH4. These films are deposited under capacitive discharge during 60 min, at a frequency of 110 kHz, substrate temperature of 300°C, pressure of 0.6 Torr, and power of 350 W. The germanium gas mixture composition, determined by XGe=[GeF4]([GeH4])/[SiH4]+[GeF4]([GeH4]), is varied from 0 to 1. These films are deposited from a (1−XGe)SiH4+(XGe)GeF4(GeH4) mixture, with H2 dilution. The refractive index n and absorption coefficient α are determined from transmission spectra. The optical energy gap is also determined. The influence of gas sources on the optical parameters is discussed. © 2005 Society of Photo-Optical Instrumentation Engineers.