Elise D'Huart

Dr. Elise D'Huart


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2022 in Antibiotics
Verified
Journal Article
Open access
PDF file
GLGuillaume Loeuille
Guillaume Loeuille
EDElise D'Huart
Elise D'Huart
JVJean Vigneron
Jean Vigneron
YNYann-Eric Nisse
Yann-Eric Nisse
BBBenoit Beiler
Benoit Beiler
ACAlexandre Charmillon
Alexandre Charmillon
The use of continuous infusion to improve the therapeutic efficacy of time-dependent antibiotics has been demonstrated. There is still a lack of data to safely perform these continuous infusions. The objectives in this study were to evaluate the stability by using stability-indicating methods (High-Performance Liquid Chromatography) of 16 antibiotics in concentrated solutions, especially for administration in intensive care units and solutions in elastomeric diffusers at 37 °C for outpatient parenteral antimicrobial therapy. The solutions were considered stable if the percentage of the drug was ≥90%, and the colour and clearness remained unchanged. In syringes, the stability data vary from 4 to 8 h (h) for meropenem in Dextrose 5% (D5W) and Normal Saline (NS), respectively, 6 h for cefotaxime, 12 h for cefoxitin, and 24 h for aztreonam, cefazolin, cefepime, cefiderocol, ceftazidime/avibactam, ceftolozane/tazobactam in NS and D5W, and in water for injection for cloxacillin. A stability period of 48 h has been validated for vancomycin (D5W), aztreonam, and piperacillin/tazobactam. Cefoxitin, cefazolin, cefepime, cefotaxime, cloxacillin, and piperacillin are unstable for diffuser administration. In diffusers, stability times vary from 6 h for cefiderocol, 8 h for ceftazidime, 12 h for ceftazidime/avibactam and ceftolozane/tazobactam (NS), 24 h for temocillin (NS) and piperacillin/tazobactam (D5W), up to 48 h for aztreonam and vancomycin. Solutions stored at 37 °C are less stable and allow the administration of seven antibiotics using diffusers.

1 January 2023 in Pharmaceutical Technology in Hospital Pharmacy
Verified
Journal Article
Open access
PDF file
JVJean Vigneron
Jean Vigneron
MSMatthieu Sacrez
Matthieu Sacrez
EDElise D'Huart
Elise D'Huart
BDBéatrice Demoré
Béatrice Demoré
Objectives: The measurement of osmolality is used by many authors as an additional stability criterion of a drug in solution. In the current state of knowledge, no scientific publication correlates the osmolality values and the stability of a solution. To study the relevance of this analytical technique by measuring the osmolality of injectable solutions whose instability has been chemically demonstrated by high performance liquid chromatography (HPLC). Methods: Selection of 13 drug preparations whose chemical instability has been demonstrated in the literature. Realization of three identical samples per selected preparation and measurements of the osmolality of the freshly prepared solutions, then, at various storage times until a chemical degradation of the molecule validated by HPLC of at least 10% and possibly up to 40%. Results: Measurements of the osmolality were performed on five antibiotics (amoxicillin/clavulanic acid, cefepime, cefoxitine, meropenem and temocillin and cefoxitin) and five anticancer drugs (azacitidine, bendamustine, busulfan, fotemustine and oxaliplatin). Osmolality varied from −6.30 to 11.10% for antibiotics and from 0.57 to 2.04%. Conclusions: Among the preparations tested, only two formulations have a variation in osmolality in accordance with the chemical degradation. For the other 11 formulas, the variations in osmolality values where not correlated with the degradation measured by HPLC. In view of these results, osmolality does not seem to be a criterion of choice for the study of drug stability. In the majority of the unstable solutions studied, the variation of osmolality measurements does not correlate with the loss of concentration and the appearance of degradation products.

1 January 2023 in Pharmaceutical Technology in Hospital Pharmacy
Verified
Journal Article
Open access
PDF file
EDElise D'Huart
Elise D'Huart
MSMatthieu Sacrez
Matthieu Sacrez
JVJean Vigneron
Jean Vigneron
NSNathalie Sobalak
Nathalie Sobalak
BDBéatrice Demoré
Béatrice Demoré
Objectives: To the best of our knowledge, few studies have been published on the stability of cabazitaxel in infusion bags. Stabilis® database has selected a study demonstrating the stability of this molecule at 0.15 mg/mL for 28 days at 4 °C and 25 °C in polyolefin bags. The aim of this work was to study the physicochemical stability of Cabazitaxel Zentiva® solutions in vials after “opening” with a vented ChemoClave® Spike, at 25 °C, protected from light and in solutions diluted at 0.1 and 0.26 mg/mL in 0.9 % sodium chloride (0.9 % NaCl) or dextrose 5 % (D5W) in 3 types of infusion bags (Easyflex® and Viaflo® at 25 °C, Freeflex® between 2 and 8 °C, protected from light). Methods: The chemical stability was analyzed after preparation and then after 14 and 28 days of storage by high performance liquid chromatography (HPLC), coupled to a diode array detector, at the analysis wavelength of 232 nm. The method has been validated according to ICH Q2 (R1) standards. For the study in infusion bags, three preparations were realised for each condition. At each time of analysis, for each bag, a sample was prepared and analyzed by HPLC. Two vials after “openings” were kept at 25 °C and three samples per vial were prepared and analyzed at the three analysis times (D0, D14 and D28). Physical stability was assessed by visual examination (change in colour, appearance of precipitate, gas formation). The pH of the solutions prepared in infusion bags was evaluated at each analysis time. Results: Cabazitaxel solutions at 0.1 and 0.26 mg/mL diluted in 0.9 % NaCl or D5W in Easyflex® (polyolefin), Viaflo® (multilayer high density polyethylene, polyamide, polypropylene) bags retained more than 95 % of the concentration after 28 days at 25 °C. In the Freeflex® bag (polypropylene multilayers), cabazitaxel solutions at 0.1 and 0.26 mg/mL diluted in 0.9 % NaCl or D5W retained more than 95 % of the initial concentration between 2 and 8 °C for 28 days. In vials with a Spike, cabazitaxel solutions at 20 mg/mL retained more than 95 % of the initial concentration for 28 days at 25 °C. For all the conditions studied, no visual modification was observed. The pH of solutions in bags were constant during the stability study. Conclusions: Cabazitaxel Zentiva® diluted at 0.1 and 0.26 mg/mL in 0.9 % NaCl or D5W was stable for 28 days at 25 °C and between 2 and 8 °C. These stability data allow preparations to be made in advance. The remainder of the cabazitaxel vial fitted with a Spike was stable for 28 days at 25 °C, allowing the remainder of the vial to be used over several days.