Pinaki Bhattacharya

Dr. Pinaki Bhattacharya

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2020 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
RSRamesh Subramani
Ramesh Subramani
AIAlicia Izquierdo-Alvarez
Alicia Izquierdo-Alvarez
PBPinaki Bhattacharya
Pinaki Bhattacharya
MMMathieu Meerts
Mathieu Meerts
PMPaula Moldenaers
Paula Moldenaers
Hans Van OosterwyckHans Van Oosterwyck
Hans Van Oosterwyck
Polyacrylamide (PAM) hydrogels are commonly used as substrates for cell mechanical and mechanobiological studies because of their tunable stiffness and ease of handling. The dependence of bulk rheological and local elastic properties (assessed by Atomic Force Microscopy, or AFM) of PAM hydrogels on its composition and polymerization temperature has been extensively studied. PAM hydrogels swell when immersed in media, but the influence of swelling on local elastic properties is poorly characterized. Direct measurements of the effect of swelling on PAM elastic properties are scarce. We report here, for the first time, the direct measurements of volumetric swelling and local elastic properties of PAM gels throughout the post-polymerization swelling process until equilibrium. First, local and global elastic properties (measured by rheology), were obtained during polymerization in the absence of swelling, and showed good agreement with each other. Four PAM hydrogel compositions were characterized thus, with corresponding storage shear moduli (as measured immediately after polymerization) of 4,530 Pa (termed stiffest), 2,900 Pa (stiff), 538 Pa (soft), and 260 Pa (softest). Next, all compositions were subjected to swelling in phosphate buffered saline. Swelling ratios and local elastic moduli were measured at 0, 3, 6, 9, 12, and 24 h post-polymerization for the soft and softest compositions, and once daily till 6 days post-polymerization for all four compositions. For the stiffest and stiff gels, swelling ratio, and local elastic modulus changed negligibly with time, while for the soft and softest gels, substantial changes between Day 0 and Day 1 were found for both swelling ratio (increased by 21.6 and 133%, respectively), and local elastic modulus decreased (by 33.7 and 33.3%, respectively), substantially. Experimental data were analyzed by a model that combined ideal elastomer mechanics and poroelastic swelling kinetics model. Model predictions confirmed the validity of present measurements with respect to past studies where swelling and elastic properties were not measured simultaneously. The present study underlines the important effect swelling can have on PAM elastic properties and provides detailed quantitative data to guide the duration taken to reach equilibrium—a useful information for cell mechanics experiments. In addition, the simultaneous measurements of swelling and local elastic moduli provide novel data for the validation of theoretical models.

14 April 2018 in Current Osteoporosis Reports
Verified
Journal Article
Open access
PDF file
Marco VicecontiMarco Viceconti
Marco Viceconti
MQMuhammad Qasim
Muhammad Qasim
PBPinaki Bhattacharya
Pinaki Bhattacharya
XLXinshan Li
Xinshan Li
Purpose of Review This study reviews the available literature to compare the accuracy of areal bone mineral density derived from dual X-ray absorptiometry (DXA-aBMD) and of subject-specific finite element models derived from quantitative computed tomography (QCT-SSFE) in predicting bone strength measured experimentally on cadaver bones, as well as their clinical accuracy both in terms of discrimination and prediction. Based on this information, some basic cost-effectiveness calculations are performed to explore the use of QCT-SSFE instead of DXA-aBMD in (a) clinical studies with femoral strength as endpoint, (b) predictor of the risk of hip fracture in low bone mass patients. Recent Findings Recent improvements involving the use of smooth-boundary meshes, better anatomical referencing for proximal-only scans, multiple side-fall directions, and refined boundary conditions increase the predictive accuracy of QCT-SSFE. Summary If these improvements are adopted, QCT-SSFE is always preferable over DXA-aBMD in clinical studies with femoral strength as the endpoint, while it is not yet cost-effective as a hip fracture risk predictor, although pathways that combine both QCT-SSFE and DXA-aBMD are promising.

1 October 2018 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
PBPinaki Bhattacharya
Pinaki Bhattacharya
ZAZainab Altai
Zainab Altai
MQMuhammad Qasim
Muhammad Qasim
Marco VicecontiMarco Viceconti
Marco Viceconti
Osteoporotic hip fractures are a major healthcare problem. Fall severity and bone strength are important risk factors of hip fracture. This study aims to obtain a mechanistic explanation for fracture risk in dependence of these risk factors. A novel modelling approach is developed that combines models at different scales to overcome the challenge of a large space–time domain of interest and considers the variability of impact forces between potential falls in a subject. The multiscale model and its component models are verified with respect to numerical approximations made therein, the propagation of measurement uncertainties of model inputs is quantified, and model predictions are validated against experimental and clinical data. The main results are model predicted absolute risk of current fracture (ARF0) that ranged from 1.93 to 81.6% (median 36.1%) for subjects in a retrospective cohort of 98 postmenopausal British women (49 fracture cases and 49 controls); ARF0 was computed up to a precision of 1.92 percentage points (pp) due to numerical approximations made in the model; ARF0 possessed an uncertainty of 4.00 pp due to uncertainties in measuring model inputs; ARF0 classified observed fracture status in the above cohort with AUC = 0.852 (95% CI 0.753–0.918), 77.6% specificity (95% CI 63.4–86.5%) and 81.6% sensitivity (95% CI 68.3–91.1%). These results demonstrate that ARF0 can be computed using the model with sufficient precision to distinguish between subjects and that the novel mechanism of fracture risk determination based on fall dynamics, hip impact and bone strength can be considered validated.

11 September 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ASAban Shuaib
Aban Shuaib
DMDaniyal Motan
Daniyal Motan
PBPinaki Bhattacharya
Pinaki Bhattacharya
AMAlex McNabb
Alex McNabb
TSTimothy M. Skerry
Timothy M. Skerry
DLDamien Lacroix
Damien Lacroix
Bone cells are exposed to dynamic mechanical stimulation that is transduced into cellular responses by mechanotransduction mechanisms. The extracellular matrix (ECM) provides a physical link between loading and bone cells, where mechanoreceptors, such as integrins, initiate mechanosensation. Though this relationship is well studied, the dynamic interplay between mechanosensation, mechanotransduction and cellular responses is unclear. A hybrid-multiscale model combining molecular, cellular and tissue interactions was developed to examine links between integrins’ mechanosensation and effects on mechanotransduction, ECM modulation and cell-ECM interaction. The model shows that altering integrin mechanosensitivity threshold (MT) increases mechanotransduction durations from hours to beyond 4 days, where bone formation starts. This is relevant to bone, where it is known that a brief stimulating period provides persistent influences for over 24 hours. Furthermore, the model forecasts that integrin heterogeneity, with respect to MT, would be able to induce sustained increase in pERK baseline > 15% beyond 4 days. This is analogous to the emergence of molecular mechanical memory signalling dynamics. Therefore, the model can provide a greater understanding of mechanical adaptation to differential mechanical responses at different times. Given reduction of bone sensitivity to mechanical stimulation with age, these findings may lead towards useful therapeutic targets for upregulation of bone mass.

1 January 2017 in Acta Biomaterialia
Verified
Journal Article
Open access
KLKimon Alexandros Leonidakis
Kimon Alexandros Leonidakis
PBPinaki Bhattacharya
Pinaki Bhattacharya
Jennifer PattersonJennifer Patterson
Jennifer Patterson
BVBart E. Vos
Bart E. Vos
GKGijsje H. Koenderink
Gijsje H. Koenderink
Hans Van OosterwyckHans Van Oosterwyck
Hans Van Oosterwyck
Fibrin hydrogels are promising carrier materials in tissue engineering. They are biocompatible and easy to prepare, they can bind growth factors and they can be prepared from a patient's own blood. While fibrin structure and mechanics have been extensively studied, not much is known about the relation between structure and diffusivity of solutes within the network. This is particularly relevant for solutes with a size similar to that of growth factors. A novel methodological approach has been used in this study to retrieve quantitative structural characteristics of fibrin hydrogels, by combining two complementary techniques, namely confocal fluorescence microscopy with a fiber extraction algorithm and turbidity measurements. Bulk rheological measurements were conducted to determine the impact of fibrin hydrogel structure on mechanical properties. From these measurements it can be concluded that variations in the fibrin hydrogel structure have a large impact on the rheological response of the hydrogels (up to two orders of magnitude difference in storage modulus) but only a moderate influence on the diffusivity of dextran solutes (up to 25% difference). By analyzing the diffusivity measurements by means of the Ogston diffusion model we further provide evidence that individual fibrin fibers can be semi-permeable to solute transport, depending on the average distance between individual protofibrils. This can be important for reducing mass transport limitations, for modulating fibrinolysis and for growth factor binding, which are all relevant for tissue engineering. Fibrin is a natural biopolymer that has drawn much interest as a biomimetic carrier in tissue engineering applications. We hereby use a novel combined approach for the structural characterization of fibrin networks based on optical microscopy and light scattering methods that can also be applied to other fibrillar hydrogels, like collagen. Furthermore, our findings on the relation between solute transport and fibrin structural properties can lead to the optimized design of fibrin hydrogel constructs for controlled release applications. Finally, we provide new evidence for the fact that fibrin fibers may be permeable for solutes with a molecular weight comparable to that of growth factors. This finding may open new avenues for tailoring mass transport properties of fibrin carriers.

19 January 2017 in WIREs Mechanisms of Disease
Verified
Journal Article
Open access
PBPinaki Bhattacharya
Pinaki Bhattacharya
Marco VicecontiMarco Viceconti
Marco Viceconti
More and more frequently, computational biomechanics deals with problems where the portion of physical reality to be modeled spans over such a large range of spatial and temporal dimensions, that it is impossible to represent it as a single space–time continuum. We are forced to consider multiple space–time continua, each representing the phenomenon of interest at a characteristic space–time scale. Multiscale models describe a complex process across multiple scales, and account for how quantities transform as we move from one scale to another. This review offers a set of definitions for this emerging field, and provides a brief summary of the most recent developments on multiscale modeling in biomechanics. Of all possible perspectives, we chose that of the modeling intent, which vastly affect the nature and the structure of each research activity. To the purpose we organized all papers reviewed in three categories: ‘causal confirmation,’ where multiscale models are used as materializations of the causation theories; ‘predictive accuracy,’ where multiscale modeling is aimed to improve the predictive accuracy; and ‘determination of effect,’ where multiscale modeling is used to model how a change at one scale manifests in an effect at another radically different space–time scale. Consistent with how the volume of computational biomechanics research is distributed across application targets, we extensively reviewed papers targeting the musculoskeletal and the cardiovascular systems, and covered only a few exemplary papers targeting other organ systems. The review shows a research subdomain still in its infancy, where causal confirmation papers remain the most common. WIREs Syst Biol Med 2017, 9:e1375. doi: 10.1002/wsbm.1375This article is categorized under: Analytical and Computational Methods > Computational Methods Models of Systems Properties and Processes > Mechanistic Models Models of Systems Properties and Processes > Organ, Tissue, and Physiological Models