André dos Santos Cabral

Prof. André dos Santos Cabral

State University of Pará, Belém, Pará, Brazil
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AMAnderson Antunes da Costa Moraes
Anderson Antunes da Costa Moraes
MDManuela Brito Duarte
Manuela Brito Duarte
EFEduardo Veloso Ferreira
Eduardo Veloso Ferreira
GAGizele Cristina da Silva Almeida
Gizele Cristina da Silva Almeida
ESEnzo Santos
Enzo Santos
BCBianca Callegari
Bianca Callegari
The evaluation of anticipatory postural adjustments (APAs) requires high-cost and complex handling systems, only available at research laboratories. New alternative methods are being developed in this field, on the other hand, to solve this issue and allow applicability in clinic, sport and hospital environments. The objective of this study was to validate an app for mobile devices to measure the APAs during gait initiation by comparing the signals obtained from cell phones using the Momentum app with measurements made by a kinematic system. The center-of-mass accelerations of a total of 20 healthy subjects were measured by the above app, which read the inertial sensors of the smartphones, and by kinematics, with a reflective marker positioned on their lumbar spine. The subjects took a step forward after hearing a command from an experimenter. The variables of the anticipatory phase, prior to the heel-off and the step phase, were measured. In the anticipatory phase, the linear correlation of all variables measured by the two measurement techniques was significant and indicated a high correlation between the devices (APAonset: r = 0.95, p < 0.0001; APAamp: r = 0.71, p = 0.003, and PEAKtime: r = 0.95, p < 0.0001). The linear correlation between the two measurement techniques for the step phase variables measured by ques was also significant (STEPinterval: r = 0.56, p = 0.008; STEPpeak1: r = 0.79, p < 0.0001; and STEPpeak2: r = 0.64, p < 0.0001). The Bland–Altman graphs indicated agreement between instruments with similar behavior as well as subjects within confidence limits and low dispersion. Thus, using the Momentum cell phone application is valid for the assessment of APAs during gait initiation compared to the gold standard instrument (kinematics), proving to be a useful, less complex, and less costly alternative for the assessment of healthy individuals.

4 May 2022 in Gait & Posture
Verified
Journal Article
Closed access
MDManuela Brito Duarte
Manuela Brito Duarte
AMAnderson Antunes da Costa Moraes
Anderson Antunes da Costa Moraes
EFEduardo Veloso Ferreira
Eduardo Veloso Ferreira
GAGizele Cristina da Silva Almeida
Gizele Cristina da Silva Almeida
ESEnzo Gabriel da Rocha Santos
Enzo Gabriel da Rocha Santos
BCBianca Callegari
Bianca Callegari

3 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TSThâmela Thaís Santos dos Santos
Thâmela Thaís Santos dos Santos
AMAmélia Pasqual Marques
Amélia Pasqual Marques
Luis Carlos Pereira MonteiroLuis Carlos Pereira Monteiro
Luis Carlos Pereira Monteiro
ESEnzo Santos
Enzo Santos
GPGustavo Henrique Lima Pinto
Gustavo Henrique Lima Pinto
BCBianca Callegari
Bianca Callegari
The Timed-Up and Go (TUG) test is widely utilized by healthcare professionals for assessing fall risk and mobility due to its practicality. Currently, test results are based solely on execution time, but integrating technological devices into the test can provide additional information to enhance result accuracy. This study aimed to assess the reliability of smartphone-based instrumented TUG (iTUG) parameters. We conducted evaluations of intra- and inter-device reliabilities, hypothesizing that iTUG parameters would be replicable across all experiments. A total of 30 individuals participated in Experiment A to assess intra-device reliability, while Experiment B involved 15 individuals to evaluate inter-device reliability. The smartphone was securely attached to participants’ bodies at the lumbar spine level between the L3 and L5 vertebrae. In Experiment A, subjects performed the TUG test three times using the same device, with a 5 min interval between each trial. Experiment B required participants to perform three trials using different devices, with the same time interval between trials. Comparing stopwatch and smartphone measurements in Experiment A, no significant differences in test duration were found between the two devices. A perfect correlation and Bland–Altman analysis indicated good agreement between devices. Intra-device reliability analysis in Experiment A revealed significant reliability in nine out of eleven variables, with four variables showing excellent reliability and five showing moderate to high reliability. In Experiment B, inter-device reliability was observed among different smartphone devices, with nine out of eleven variables demonstrating significant reliability. Notable differences were found in angular velocity peak at the first and second turns between specific devices, emphasizing the importance of considering device variations in inertial measurements. Hence, smartphone inertial sensors present a valid, applicable, and feasible alternative for TUG assessment.

11 December 2023 in Frontiers in Neurology
Verified
Journal Article
Open access
BCBruna Danielle Campelo Corrêa
Bruna Danielle Campelo Corrêa
ESEnzo Santos
Enzo Santos
ABAnderson Belgamo
Anderson Belgamo
GPGustavo Henrique Lima Pinto
Gustavo Henrique Lima Pinto
SXStanley Soares Xavier
Stanley Soares Xavier
Givago SouzaGivago Souza
Givago Souza
Background: SARS-CoV-2 infection can lead to a variety of persistent sequelae, collectively known as long COVID-19. Deficits in postural balance have been reported in patients several months after COVID-19 infection. The purpose of this study was to evaluate the static balance and balance of individuals with long COVID-19 using inertial sensors in smartphones.Methods: A total of 73 participants were included in this study, of which 41 had long COVID-19 and 32 served as controls. All participants in the long COVID-19 group reported physical complaints for at least 7 months after SARS-CoV-2 infection. Participants were evaluated using a built-in inertial sensor of a smartphone attached to the low back, which recorded inertial signals during a static balance and mobility task (timed up and go test). The parameters of static balance and mobility obtained from both groups were compared.Results: The groups were matched for age and BMI. Of the 41 participants in the long COVID-19 group, 22 reported balance impairment and 33 had impaired balance in the Sharpened Romberg test. Static balance assessment revealed that the long COVID-19 group had greater postural instability with both eyes open and closed than the control group. In the TUG test, the long COVID-19 group showed greater acceleration during the sit-to-stand transition compared to the control group.Conclusion: The smartphone was feasible to identify losses in the balance motor control and mobility of patients with long-lasting symptomatic COVID-19 even after several months or years. Attention to the balance impairment experienced by these patients could help prevent falls and improve their quality of life, and the use of the smartphone can expand this monitoring for a broader population.

15 April 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KCKetlin Jaquelline Santana Castro
Ketlin Jaquelline Santana Castro
RSRailson Cruz Salomão
Railson Cruz Salomão
NFNewton Quintino Feitosa
Newton Quintino Feitosa
LHLeonardo Dutra Henriques
Leonardo Dutra Henriques
AKAna Francisca Rozin Kleiner
Ana Francisca Rozin Kleiner
Givago SouzaGivago Souza
Givago Souza
We investigated the impact of visual impairment on balance control. We measured the center of pressure (COP) between the two feet and plantar surface pressures on each foot in 18 normal-sighted participants and compared their data with measures from 18 legally blind participants, either acquired or congenital. Pressures were measured in open- and closed-eye conditions using a baropodometric resistive plate. In the eyes-open condition, there were no differences between the sighted and legally blind groups in COP displacement. However, participants with visual loss had significantly increased pressures in two metatarsal regions (M1 and M2 zones) of the plantar surface in both viewing conditions (p < 0.05). The differences in pressure measures between the normally sighted and legally blind groups could be attributed mainly to the subgroup of subjects with acquired impairment. Our findings suggest that subjects with visual impairment present increased metatarsal pressures (i.e. forefoot), not yet associated to anterior displacement of COP or impaired balance control.

28 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MDManuela Brito Duarte
Manuela Brito Duarte
AMAnderson Antunes da Costa Moraes
Anderson Antunes da Costa Moraes
EFEduardo Veloso Ferreira
Eduardo Veloso Ferreira
GAGizele Cristina da Silva Almeida
Gizele Cristina da Silva Almeida
ACAndré dos Santos Cabral
André dos Santos Cabral
BCBianca Callegari
Bianca Callegari
Introduction: Evidence supports the importance of efficient postural control to improve performance in sports. This involves the use of strategies such as anticipatory posture adjustments and compensatory adjustments. Technology makes analysis and assessments in sports cheaper, while being valid and reliable compared to the gold-standard assessment equipment. Objectives: This article aimed to test the validity and reliability of signals extracted from the sensor’s accelerometer (Metamotion C), by comparing it to the data obtained from the gold-standard equipment (a three-dimensional video-motion-capture system). Design: Observational, cross-sectional study. Methods: We exposed 20 healthy young standing people to the pendulum impact paradigm, which consisted of predictable anteroposterior disturbances applied at the shoulder level. In order to measure this, we observed the acceleration of the center of mass in the anticipatory and compensatory phase of the disturbance and compared the signals of the two devices (Metamotion C and a motion-capture system). Results: The validation results showed the significant linear correlation of all variables with a moderate to large correlation of r ≥ 0.5 between the devices. In contrast, the reliability results between sessions obtained by filming were all significant and above 0.75, indicating excellent reliability. The APAonset variable had a reasonable to high intra-class correlation in the anticipatory phase. In the compensatory phase, the CPAtime variable showed an excellent correlation. Conclusions: Metamotion C proved reasonably valid and highly reliable in measuring the center of mass acceleration compared to the camera system in both the anticipatory and compensatory phases.