Joop Jonckheer

Dr. Joop Jonckheer

Universitair Ziekenhuis Brussel, Brussels, Brussels-Capital Region, Belgium
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Environment International
Verified
Journal Article
Open access
VVVânia Vilas-Boas
Vânia Vilas-Boas
EGEva Gijbels
Eva Gijbels
JJJoop Jonckheer
Joop Jonckheer
EWElisabeth De Waele
Elisabeth De Waele
Mathieu VinkenMathieu Vinken
Mathieu Vinken
Cholestasis refers to the accumulation of toxic levels of bile acids in the liver due to defective bile secretion. This pathological situation can be triggered by drugs, but also by ingredients contained in food, food supplements and parenteral nutrition. This paper provides an overview of the current knowledge on cholestatic injury associated with such ingredients, with particular emphasis on the underlying mechanisms of toxicity.

6 November 2018 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Closed access
PDF file
EWElisabeth De Waele
Elisabeth De Waele
JJJoop Jonckheer
Joop Jonckheer
JPJoeri J. Pen
Joeri J. Pen
JDJoy Demol
Joy Demol
KSKurt Staessens
Kurt Staessens
HSHerbert D. Spapen
Herbert D. Spapen

1 December 2020 in Clinical Nutrition
Verified
Journal Article
Open access
JJJoop Jonckheer
Joop Jonckheer
JDJ. Demol
J. Demol
KLK. Lanckmans
K. Lanckmans
Manu MalbrainManu Malbrain
Manu Malbrain
HSH. Spapen
H. Spapen
EWE. De Waele
E. De Waele
And aims: Caloric prescription based on resting energy expenditure (REE) measured with indirect calorimetry (IC) improves outcome and is the gold standard in nutritional therapy of critically ill patients. Until now continuous renal replacement therapy (CRRT) precluded the use of IC due to several mechanisms. We investigated the impact of CRRT on V̇CO2, V̇O2 and REE to facilitate indirect calorimetry during CRRT. In 10 critically ill ventilated patient in need of continuous veno-venous hemofiltration (CVVH) using citrate predilution we performed IC in 4 different states: baseline, high dose, baseline with NaCl predilution and without CVVH. CO2 content of effluent fluid was measured by a point of care blood gas analyzer. Carbon dioxide production (V̇CO2) measured with IC was adapted by adding the CO2 flow of effluent and deducing CO2 flow in postdilution fluid to calculate a true V̇CO2. True REE was calculated with the Weir equation using the true V̇CO2. CO2 removal in effluent during baseline, high dose and NaCl predilution was respectively 24 mL/min, 38 mL/min and 23 mL/min. Together with the CO2 delivery by the postdilution fluid this led to an adaptation of REE respectively by 34 kcal/d or 2% (p = 0,002), 44 kcal/d or 3% (p = 0,002) and 33 kcal/d or 2% (p = 0,002). Compared to the true REE during baseline of 1935 ± 921 kcal/d, true REE during high dose was 1723 ± 752 kcal/d (p = 0.65), during NaCl predilution it was 1604 ± 633 kcal/d (p = 0.014) and without CRRT it was 1713 ± 704 kcal/d (p = 0.193). CO2 alterations due to CVVH are clinically of no importance so no correction factor of REE is needed with or without CVVH. IC must be performed during CVVH as CVVH seems to alter metabolism. These changes may be mainly explained by the use of citrate predilution.

20 December 2018 in Nutrition in Clinical Practice
Verified
Journal Article
Open access
PDF file
JJJoop Jonckheer
Joop Jonckheer
KVKlaar Vergaelen
Klaar Vergaelen
HSHerbert Spapen
Herbert Spapen
Manu MalbrainManu Malbrain
Manu Malbrain
EWElisabeth De Waele
Elisabeth De Waele
Introduction: Nutrition is an important part of treatment in critically ill children. Clinical guidelines for nutrition adaptations during continuous renal replacement therapy (CRRT) are lacking. We collected and evaluated current knowledge on this topic and provide recommendations.Methods: Questions were produced to guide the literature search in the PubMed database.Results: Evidence is scarce and extrapolation from adult data was often required. CRRT has a direct and substantial impact on metabolism. Indirect calorimetry is the preferred method to assess resting energy expenditure (REE). Moderate underestimation of REE is common but not clinically relevant. Formula‐based calculation of REE is inaccurate and not validated in critically ill children on CRRT. The nutrition impact of nonintentional calories delivered as citrate, lactate, and glucose during CRRT must be considered. Quantifying nitrogen balance is not feasible during CRRT. Protein delivery should be increased by 25% to compensate for losses in the effluent. Fats are not removed by CRRT and should not be adapted during CRRT. Electrolyte disturbances are frequently present and should be treated accordingly. Vitamins B1, B6, B9, and C are lost in the effluent and should be adapted to the effluent dose. Trace elements, with the exception of selenium, are not cleared in relevant quantities. Manganese accumulation is of concern because of potential neurotoxicity.Conclusion: Current recommendations regarding nutrition support in pediatric CRRT must be extrapolated from adult studies. Recommendations are provided, based on the weak level of evidence. Additional research on this topic is warranted.

1 February 2020 in Clinical Nutrition
Verified
Journal Article
Open access
JJJoop Jonckheer
Joop Jonckheer
HSH. Spapen
H. Spapen
Manu MalbrainManu Malbrain
Manu Malbrain
TOT. Oschima
T. Oschima
EWElisabeth De Waele
Elisabeth De Waele
Indirect calorimetry (IC) is the gold standard for measuring energy expenditure in critically ill patients However, continuous renal replacement therapy (CRRT) is a formal contraindication for IC use. To discuss specific issues that hamper or preclude an IC-based assessment of energy expenditure and correct caloric prescription in CRRT-treated patients. Narrative review of current literature. Several relevant pitfalls for validation of IC during CRRT were identified. First, IC measures CO2 production (VCO2) and O2 consumption to calculate resting energy expenditure (REE) with the Weir equation. VCO2 measurements are influenced by CRRT because CO2 is exchanged during the blood purification process. CO2 exchange also depends on type of pre- and/or postdilution fluid(s). CO2 dissolves in different forms with dynamic but unpredictable impact on VCO2. Second, the effect of immunologic activation and heat loss on REE caused by extracorporeal circulation during CRRT is poorly documented. Third, caloric prescription should be adapted to CRRT-induced in- and efflux of different nutrients. Finally, citrate, which is the preferred anticoagulant for CRRT, is a caloric source that may influence IC measurements and REE. Better understanding of CRRT-related processes is needed to assess REE and provide individualized nutritional therapy in this condition.

17 June 2019 in BMC Nephrology
Verified
Journal Article
Open access
PDF file
JJJoop Jonckheer
Joop Jonckheer
HSHerbert Spapen
Herbert Spapen
ADAziz Debain
Aziz Debain
JDJoy Demol
Joy Demol
MDMarc Diltoer
Marc Diltoer
EWElisabeth De Waele
Elisabeth De Waele
Carbon dioxide (CO2) accumulation is a challenging issue in critically ill patients. CO2 can be eliminated by renal replacement therapy but studies are scarce and clinical relevance is unknown. We prospectively studied CO2 and O2 behavior at different sample points of continuous veno-venous hemofiltration (CVVH) and build a model to calculate CO2 removal bedside. In 10 patients receiving standard CVVH under citrate anticoagulation, blood gas analysis was performed at different sample points within the CVVH circuit. Citrate was then replaced by NaCl 0.9% and sampling was repeated. Total CO2 (tCO2), CO2 flow (V̇CO2) and O2 flow (V̇O2) were compared between different sample points. The effect of citrate on transmembrane tCO2 was evaluated. Wilcoxon matched-pairs signed rank test was performed to evaluate significance of difference between 2 data sets. Friedman test was used when more data sets were compared. V̇CO2 in the effluent (26.0 ml/min) correlated significantly with transmembrane V̇CO2 (24.2 ml/min). This represents 14% of the average expired V̇CO2 in ventilated patients. Only 1.3 ml/min CO2 was removed in the de-aeration chamber, suggesting that CO2 was almost entirely cleared across the membrane filter. tCO2 values in effluent, before, and after the filter were not statistically different. Transmembrane tCO2 under citrate or NaCl 0.9% predilution also did not differ significantly. No changes in V̇O2 were observed throughout the CVVH circuit. Based on recorded data, formulas were constructed that allow bedside evaluation of CVVH-attributable CO2 removal. A relevant amount of CO2 is removed by CVVH and can be quantified by one simple blood gas analysis within the circuit. Future studies should assess the clinical impact of this observation. The trial was registered at https://clinicaltrials.gov with trial registration number NCT03314363 on October 192,017.