Background: Postprandial (PP) control remains a challenge for closed-loop (CL) systems. Few studies with inconsistent results have systematically investigated the PP period. Objective: To compare a new CL algorithm with current pump therapy (open loop [OL]) in the PP glucose control in type 1 diabetes (T1D) subjects. Methods: A crossover randomized study was performed in two centers. Twenty T1D subjects (F/M 13/7, age 40.7 ± 10.4 years, disease duration 22.6 ± 9.9 years, and A1c 7.8% ± 0.7%) underwent an 8-h mixed meal test on four occasions. In two (CL1/CL2), after meal announcement, a bolus was given followed by an algorithm-driven basal infusion based on continuous glucose monitoring (CGM). Alternatively, in OL1/OL2 conventional pump therapy was used. Main outcome measures were as follows: glucose variability, estimated with the coefficient of variation (CV) of the area under the curve (AUC) of plasma glucose (PG) and CGM values, and from the analysis of the glucose time series; mean, maximum (Cmax), and time to Cmax glucose concentrations and time in range (180 mg/dL). Results: CVs of the glucose AUCs were low and similar in all studies (around 10%). However, CL achieved greater reproducibility and better PG control in the PP period: CL1 = CL2<OL1<OL2 (PGmean 123 ± 47 and 125 ± 44 vs. 152 ± 53 and 159 ± 54 mg/dL) and Cmax OL 217.1 ± 67.0 mg/dL versus CL 183.3 ± 63.9 mg/dL, P < 0.0001. Time-in-range was higher with CL versus OL (80% vs. 64%; P < 0.001). Neither the time below 70 mg/dL (CL 6.1% vs. OL 3.2%; P > 0.05) nor the need for oral glucose was significantly different (CL 40.0% vs. OL 22.5% of meals; P = 0.054). Conclusions: This novel CL algorithm effectively and consistently controls PP glucose excursions without increasing hypoglycemia. Study registered at ClinicalTrials.gov: study number NCT02100488.
6 October 2020 in Diabetes Technology & Therapeutics
Objective: Increasing use of continuous glucose monitoring (CGM) data has created an array of glucose metrics for glucose variability, temporal patterns, and times in ranges. However, a gold standard metric has not been defined. We assess the performance of multiple glucose metrics to determine their ability to detect intra- and interperson variability to determine a set of recommended metrics. Methods: The Juvenile Diabetes Research Foundation data set, a randomized controlled study of CGM and self-monitored blood glucose conducted in children and adults with type 1 diabetes (T1D), was used. To determine the ability of the evaluated glycemic metrics to discriminate between different subjects and attenuate the effect of within-subject variation, the discriminant ratio was calculated and compared for each metric. Then, the findings were confirmed using data from two other recent randomized clinical trials. Results: Mean absolute glucose (MAG) has the highest discriminant ratio value (2.98 [95% confidence interval {CI} 1.64–3.67]). In addition, low blood glucose index and index of glycemic control performed well (1.93 [95% CI 1.15–3.44] and 1.92 [95% CI 1.27–2.93], respectively). For percentage times in glucose target ranges, the optimal discriminator was percentage time in glucose target 70–180 mg/dL. Conclusions: MAG is the optimal index to differentiate glucose variability in people with T1D, and may be a complementary therapeutic monitoring tool in addition to glycated hemoglobin and a measure of hypoglycemia. Percentage time in glucose target 70–180 mg/dL is the optimal percentage time in range to report.
30 December 2021 in Urban Forestry & Urban Greening
OBJECTIVE The Diabetes Control and Complications Trial identified an inverse relationship between HbA1c and severe hypoglycemia. We investigated the relationship between hypoglycemia and HbA1c in a large type 1 diabetes cohort on multiple daily injection or insulin pump therapy using blinded continuous glucose monitoring (CGM) data. The impact of real-time CGM on these relationships and how these relationships differ with biochemical definitions of hypoglycemia have also been assessed. RESEARCH DESIGN AND METHODS CGM data were obtained from the JDRF CGM randomized control trial. Baseline blinded-CGM data were used to assess time in hypoglycemia in all individuals. End-point data from the CGM intervention group were used to assess the impact of CGM. Percentage times <3.9, 3.3, 3.0, and 2.8 mmol/L were calculated and quadratic regression plots drawn. Relationships were analyzed visually, and ANOVA was used to assess relationships between glycemia and time below threshold. RESULTS J-shaped relationships were observed for all biochemical hypoglycemia thresholds, with the lowest hypoglycemia risk occurring at HbA1c values between 8.1 and 8.6% (65–70 mmol/mol). The use of an average of 5 days/week of CGM flattened the relationships for 3.3, 3.0, and 2.8 mmol/L, and ANOVA confirmed the loss of relationship for the 3.3 mmol/L threshold using CGM. CONCLUSIONS The relationship between hypoglycemia and HbA1c in a population with type 1 diabetes is J-shaped. Lower HbA1c values are still associated with increased hypoglycemia risk, although the magnitude of risk depends on biochemical threshold. Real-time CGM may reduce the percentage time spent in hypoglycemia, changing the relationship between HbA1c and hypoglycemia.
2 August 2019 in Journal of Diabetes Science and Technology
The I-HART CGM study has shown that real-time continuous glucose monitoring (rtCGM) has greater beneficial impact on hypoglycemia than intermittently scanned continuous glucose monitoring (iscCGM) in adults with type 1 diabetes at high risk (Gold score ≥4 or recent severe hypoglycemia using insulin injections). In this subanalysis, we present the impact of rtCGM and iscCGM on glycemic variability (GV). Forty participants were recruited to this parallel group study. Following two weeks of blinded rtCGM (DexcomG4), participants were randomized to rtCGM (Dexcom G5; n = 20) or iscCGM (Freestyle Libre; n = 20) for eight weeks. An open-extension phase enabled participants on rtCGM to continue for a further eight weeks and those on iscCGM to switch to rtCGM over this period. Glycemic variability measures at baseline, 8- and 16-week endpoints were compared between groups. At the eight-week endpoint, between-group differences demonstrated significant reduction in several GV measures with rtCGM compared to iscCGM (GRADE%hypoglycemia, index of glycemic control [IGC], and average daily risk range [ADRR]; P < .05). Intermittently scanned continuous glucose monitoring reduced mean average glucose and glycemic variability percentage and GRADE%hyperglycemia compared with rtCGM (P < .05). At 16 weeks, the iscCGM group switching to rtCGM showed significant improvement in GRADE%hypoglycemia, personal glycemic status, IGC, and ADRR. Our data suggest most, but not all, GV measures improve with rtCGM compared with iscCGM, particularly those measures associated with the risk of hypoglycemia. Selecting appropriate glucose monitoring technology to address GV in this high-risk cohort is important to minimize the risk of glucose extremes and severe hypoglycemia. ClinicalTrials.gov NCT03028220
OBJECTIVE The inverse relationship between overall glucose control and hypoglycemia risk is weakened by the use of real-time continuous glucose monitoring (rtCGM). We assess the relationship between glucose control and hypoglycemia in people with type 1 diabetes using multiple-dose injection (MDI) regimens, including those at highest risk of hypoglycemia. RESEARCH DESIGN AND METHODS CGM data from the intervention (rtCGM) and control (self-monitored blood glucose [SMBG]) phases of the Multiple Daily Injections and Continuous Glucose Monitoring in Diabetes (DIAMOND) and HypoDE studies were analyzed. The relationship between glucose control (HbA1c and mean rtCGM glucose levels) and percentage time spent in hypoglycemia was explored for thresholds of 3.9 mmol/L (70 mg/dL) and 3.0 mmol/L (54 mg/dL), and ANOVA across the range of HbA1c and mean glucose was performed. RESULTS A nonlinear relationship between mean glucose and hypoglycemia was identified at baseline, with the steepest relationship seen at lower values of mean glucose. The use of rtCGM reduces the exposure to hypoglycemia at all thresholds and flattens the relationship between overall glucose and hypoglycemia, with the most marked impact at lower values of mean glucose and HbA1c. Exposure to hypoglycemia varied at all thresholds across the range of overall glucose at baseline, in the SMBG group, and with rtCGM, but the relationships were weaker in the rtCGM group. CONCLUSIONS Use of rtCGM can flatten and attenuate the relationship between overall glucose control and hypoglycemia, exerting its greatest impact at lower values of HbA1c and mean glucose in people with type 1 diabetes using MDI regimens and at highest risk of hypoglycemia.