Tadej Battelino

Prof. Tadej Battelino

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2019 in Diabetes Care
Verified
Journal Article
Closed access
PDF file
TBTadej Battelino
Tadej Battelino
TDThomas Danne
Thomas Danne
RBRichard M. Bergenstal
Richard M. Bergenstal
SAStephanie A. Amiel
Stephanie A. Amiel
RBRoy Beck
Roy Beck
MPMoshe Phillip
Moshe Phillip
Improvements in sensor accuracy, greater convenience and ease of use, and expanding reimbursement have led to growing adoption of continuous glucose monitoring (CGM). However, successful utilization of CGM technology in routine clinical practice remains relatively low. This may be due in part to the lack of clear and agreed-upon glycemic targets that both diabetes teams and people with diabetes can work toward. Although unified recommendations for use of key CGM metrics have been established in three separate peer-reviewed articles, formal adoption by diabetes professional organizations and guidance in the practical application of these metrics in clinical practice have been lacking. In February 2019, the Advanced Technologies & Treatments for Diabetes (ATTD) Congress convened an international panel of physicians, researchers, and individuals with diabetes who are expert in CGM technologies to address this issue. This article summarizes the ATTD consensus recommendations for relevant aspects of CGM data utilization and reporting among the various diabetes populations.

10 November 2017 in Diabetes Care
Verified
Journal Article
Closed access
PDF file
TDThomas Danne
Thomas Danne
RNRevital Nimri
Revital Nimri
TBTadej Battelino
Tadej Battelino
RBRichard M. Bergenstal
Richard M. Bergenstal
KCKelly L. Close
Kelly L. Close
MPMoshe Phillip
Moshe Phillip
Measurement of glycated hemoglobin (HbA1c) has been the traditional method for assessing glycemic control. However, it does not reflect intra- and interday glycemic excursions that may lead to acute events (such as hypoglycemia) or postprandial hyperglycemia, which have been linked to both microvascular and macrovascular complications. Continuous glucose monitoring (CGM), either from real-time use (rtCGM) or intermittently viewed (iCGM), addresses many of the limitations inherent in HbA1c testing and self-monitoring of blood glucose. Although both provide the means to move beyond the HbA1c measurement as the sole marker of glycemic control, standardized metrics for analyzing CGM data are lacking. Moreover, clear criteria for matching people with diabetes to the most appropriate glucose monitoring methodologies, as well as standardized advice about how best to use the new information they provide, have yet to be established. In February 2017, the Advanced Technologies & Treatments for Diabetes (ATTD) Congress convened an international panel of physicians, researchers, and individuals with diabetes who are expert in CGM technologies to address these issues. This article summarizes the ATTD consensus recommendations and represents the current understanding of how CGM results can affect outcomes.

6 December 2022 in The Lancet Diabetes & Endocrinology
Verified
Journal Article
Closed access
TBTadej Battelino
Tadej Battelino
CACharles M Alexander
Charles M Alexander
SAStephanie A Amiel
Stephanie A Amiel
GAGuillermo Arreaza-Rubin
Guillermo Arreaza-Rubin
RBRoy W Beck
Roy W Beck
MPMoshe Phillip
Moshe Phillip

1 February 2010 in Journal of Experimental Medicine
Verified
Journal Article
Open access
KKKalle Kisand
Kalle Kisand
AWAnette S. Bøe Wolff
Anette S. Bøe Wolff
KPKatarina Trebušak Podkrajšek
Katarina Trebušak Podkrajšek
LTLiina Tserel
Liina Tserel
MLMaire Link
Maire Link
AMAnthony Meager
Anthony Meager
Chronic mucocutaneous candidiasis (CMC) is frequently associated with T cell immunodeficiencies. Specifically, the proinflammatory IL-17A–producing Th17 subset is implicated in protection against fungi at epithelial surfaces. In autoimmune polyendocrinopathy candidiasis ectodermal dystrophy (APECED, or autoimmune polyendocrine syndrome 1), CMC is often the first sign, but the underlying immunodeficiency is a long-standing puzzle. In contrast, the subsequent endocrine features are clearly autoimmune, resulting from defects in thymic self-tolerance induction caused by mutations in the autoimmune regulator (AIRE). We report severely reduced IL-17F and IL-22 responses to both Candida albicans antigens and polyclonal stimulation in APECED patients with CMC. Surprisingly, these reductions are strongly associated with neutralizing autoantibodies to IL-17F and IL-22, whereas responses were normal and autoantibodies infrequent in APECED patients without CMC. Our multicenter survey revealed neutralizing autoantibodies against IL-17A (41%), IL-17F (75%), and/ or IL-22 (91%) in >150 APECED patients, especially those with CMC. We independently found autoantibodies against these Th17-produced cytokines in rare thymoma patients with CMC. The autoantibodies preceded the CMC in all informative cases. We conclude that IL-22 and IL-17F are key natural defenders against CMC and that the immunodeficiency underlying CMC in both patient groups has an autoimmune basis.

1 December 2006 in Diabetes Care
Verified
Journal Article
Closed access
PDF file
DDDorothee Deiss
Dorothee Deiss
JBJan Bolinder
Jan Bolinder
JRJean-Pierre Riveline
Jean-Pierre Riveline
TBTadej Battelino
Tadej Battelino
EBEmanuele Bosi
Emanuele Bosi
MPMoshe Phillip
Moshe Phillip
Intensive self-management with frequent self-monitoring of blood glucose (SMBG) is important in type 1 diabetes to achieve good metabolic control (1–3). Nevertheless, many patients still experience episodes of unrecognized hypo- and hyperglycemia (4). Novel technologies for continuous glucose monitoring (CGM) that provide information about glucose excursions are now available. Previous studies reported the benefits of retrospective evaluation of CGM data (5–11), but few assessed effects on glycemic control (5,12–14), and only one showed improvements compared with SMBG (14). We evaluated the effect of a new real-time glucose monitor on glycemic control in patients with poorly controlled type 1 diabetes. The device, Guardian RT (Medtronic MiniMed, Northridge, CA), allows users to see glucose readings and set hypo- and hyperglycemic alarms and provides trend information on changing glucose values. The study included 81 children (median age 14.4 years [range 8.0–18.9]) and 81 adults (age 39.1 years [19.0–59.5]) with stable type 1 diabetes. All had adhered to intensified insulin treatment (continuous subcutaneous insulin infusion, n = 78; multiple daily injection, n = 84) but had HbA1c (A1C) levels ≥8.1%. Informed consent was obtained from patients regularly attending the eight participating centers. Subjects were randomly assigned 1:1:1 for 3 months to Guardian RT continuously (arm 1) or biweekly for 3-day periods every 2 weeks (arm 2) or to continue conventional SMBG (control). Treatment adjustments made by physicians and patients were based on SMBG profiles in control subjects and on real-time glucose profiles in arms 1 and 2. Patients were instructed to perform confirmatory SMBG measurements before therapeutical interventions or corrective action if hypo- or hyperglycemic alarms or symptoms occurred. …

11 September 2012 in Diabetologia
Verified
Journal Article
Open access
PDF file
TGthe SWITCH Study Group
the SWITCH Study Group
TBTadej Battelino
Tadej Battelino
ICI. Conget
I. Conget
BOB. Olsen
B. Olsen
ISI. Schütz-Fuhrmann
I. Schütz-Fuhrmann
JBJ. Bolinder
J. Bolinder
Aims/hypothesis The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes. Methods Children and adults (n = 153) on CSII with HbA1c 7.5–9.5% (58.5–80.3 mmol/mol) were randomised to (CGM) a Sensor On or Sensor Off arm for 6 months. After 4 months’ washout, participants crossed over to the other arm for 6 months. Paediatric and adult participants were separately electronically randomised through the case report form according to a predefined randomisation sequence in eight secondary and tertiary centres. The primary outcome was the difference in HbA1c levels between arms after 6 months. Results Seventy-seven participants were randomised to the On/Off sequence and 76 to the Off/On sequence; all were included in the primary analysis. The mean difference in HbA1c was –0.43% (–4.74 mmol/mol) in favour of the Sensor On arm (8.04% [64.34 mmol/mol] vs 8.47% [69.08 mmol/mol]; 95% CI −0.32%, −0.55% [−3.50, −6.01 mmol/mol]; p < 0.001). Following cessation of glucose sensing, HbA1c reverted to baseline levels. Less time was spent with sensor glucose <3.9 mmol/l during the Sensor On arm than in the Sensor Off arm (19 vs 31 min/day; p = 0.009). The mean number of daily boluses increased in the Sensor On arm (6.8 ± 2.5 vs 5.8 ± 1.9, p < 0.0001), together with the frequency of use of the temporary basal rate (0.75 ± 1.11 vs 0.26 ± 0.47, p < 0.0001) and manual insulin suspend (0.91 ± 1.25 vs 0.70 ± 0.75, p < 0.018) functions. Four vs two events of severe hypoglycaemia occurred in the Sensor On and Sensor Off arm, respectively (p = 0.40). Conclusions/interpretation Continuous glucose monitoring was associated with decreased HbA1c levels and time spent in hypoglycaemia in individuals with type 1 diabetes using CSII. More frequent self-adjustments of insulin therapy may have contributed to these effects. Trial registration ClinicalTrials.gov registration no. NCT00598663. Funding The study was funded by Medtronic International Trading Sarl Switzerland.