Jiale Fu

Prof. Dr. Jiale Fu

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2022 in Materials
Verified
Journal Article
Open access
PDF file
WHWenkai Huang
Wenkai Huang
LRLing Ren
Ling Ren
YCYuyao Cheng
Yuyao Cheng
MXminghua XU
minghua XU
WLWenji Luo
Wenji Luo
JFJiale Fu
Jiale Fu
This study aims to assess the color stability, water sorption, and solubility of 11 resin composites as commercially available dental products. Twenty samples (10 mm in diameter and 2 mm in thickness) of each material were fabricated using a customized silicone mold, followed by immersion in each of curry, coffee, wine, and distilled water for 28 days (n = 5). Baseline shade and color changes (ΔE) were measured using a reflection spectrophotometer. The CIE L*, a*, b* system was used to evaluate the color changes. Five samples of each resin composite were applied to test water sorption and solubility according to ISO 4049:2009. As a result, the ∆E values were significantly influenced by each of the three factors (composition of material, solution, time) and the interactions between them (p < 0.001). Highest resistance to discoloration was achieved by Ceram.X One Universal (CXU), followed by Magnafill Putty (MP). Generally, microhybrid composites showed fewer color changes than nanohybrid composites and giomers. DX. Universal and Filtek Z350 XT showed the highest ΔE values in all colorants. All materials tested in this study fulfilled the criteria of ISO 4049:2009; CXU and MP had the lowest water sorption and solubility. The Pearson test showed statistically significant positive correlations between water sorption and ΔE and between solubility and ΔE.

1 January 2013 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
JFJiale Fu
Jiale Fu
SKShinichi Kakuda
Shinichi Kakuda
FPFeng Pan
Feng Pan
SHShuhei Hoshika
Shuhei Hoshika
STShihchun Ting
Shihchun Ting
SSSharanbir K. Sidhu
Sharanbir K. Sidhu
The purpose of this study was to evaluate the short-term µTBS (Micro-tensile bond strength) and microscopic (SEM and TEM) observation of four recent adhesives. One adhesive was an experimental step-less 1-step system (LLB-2, Tokuyama Dental), which is an all-in-one system without the light-curing step in the application process. The other two were self-adhering light-cured flowable composite resin systems FLD (Fusio Liquid Dentin, Pentron Clinical Technologies) and VF (Vertise Flow Dental Restorative Materials, Kerr Corporation), which combine all the bonding steps together. A 2-step self-etching system MG (Clearfil MegaBond, Kuarary Medical) was employed as the control group in this study. The µTBS of MG was the highest (79.0 MPa) followed by that of LLB-2 (63.1 MPa), FLD (23.6 MPa), and VF (13.1 MPa). The microscopic observations showed that MG and LLB-2 had an approximately 20 µm and 5 µm adhesive layer respectively, without bubble or gap-formation at the resin-dentin interface, which were found in FLD and VF.

1 August 2017 in Dental Materials
Verified
Journal Article
Closed access
JFJiale Fu
Jiale Fu
PSPipop Saikaew
Pipop Saikaew
SKShimpei Kawano
Shimpei Kawano
RCRicardo M. Carvalho
Ricardo M. Carvalho
MHMatthias Hannig
Matthias Hannig
DSDenis Selimovic
Denis Selimovic

1 January 2012 in Dental Materials Journal
Verified
Journal Article
Closed access
JFJiale Fu
Jiale Fu
FPFeng Pan
Feng Pan
SKShinichi Kakuda
Shinichi Kakuda
SSSharanbir K Sidhu
Sharanbir K Sidhu
TITakatsumi Ikeda
Takatsumi Ikeda
HSHidehiko Sano
Hidehiko Sano
The purpose of this study was to evaluate the effect of air-blowing duration on the bonding performance of all-in-one systems using the same pressure (0.25 MPa). Three all-in-one systems were: EB (Easy Bond, 3M ESPE, USA), BB (BeautiBond, Shofu Inc., Japan) and GBp (G-Bond plus, GC Corporation, Japan). After adhesive application, the 3 systems were air-blown thereafter using 7 different durations (5 s, 10 s, 15 s, 20 s, 25 s, 30 s and 35 s). Bond strengths to dentin were determined using µTBS test after 24 h water storage. In addition, evaluation of both the resin-dentin interface and the fractured surface on the dentin side were performed by SEM. The maximum µTBS for each system, BB (40.4±14.8 MPa), EB (79.8±16.5 MPa), and GBp (47.3±17.6 MPa), were recorded with 15 s, 15 s and 25 s air-blowing duration respectively. Under the same air-pressure, the air-blowing duration could affect evaporation and the thickness of the adhesive layer, which contributed to the different bond strengths.

25 September 2022 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
BHBo Hu
Bo Hu
YHYichun Hu
Yichun Hu
XLXiangyi Li
Xiangyi Li
JGJiayang Gao
Jiayang Gao
RSRuitong Sun
Ruitong Sun
JFJiale Fu
Jiale Fu
This study aimed to evaluate the shear bond strength (SBS) of four bonding agents used to bond metal brackets to zirconia under different storage conditions. Four bonding agents were used [FLC: (Fuji ORTHO LC), XT: (TransbondTM XT), RUC-SBU: (Rely XTM Ultimate Clicker Adhesive Resin Cement+Single Bond Universal), and RUC-GBU: (Rely XTM Ultimate Clicker Adhesive Resin Cement+Gluma Bond Universal)] to bond two types of metal brackets (PT/3M) to zirconia surfaces, and they were stored in water at 37ºC for 24 h or thermocycling for 3,000 cycles. The SBS data of RUC-SBU and RUC-GBU using PT brackets were significantly higher than those of 3M brackets before and after thermocycling. It could be concluded that RUC-SBU and RUC-GBU could offer sufficient bond strength between metal brackets and zirconia for the short term compared with FLC and XT. The design of brackets can significantly affect the bond strength to zirconia.

25 January 2021 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
YCYue Chen
Yue Chen
XYXiaoyuan Yan
Xiaoyuan Yan
KLKe Li
Ke Li
SZShize Zheng
Shize Zheng
HSHidehiko Sano
Hidehiko Sano
JFJiale Fu
Jiale Fu
The purpose of this study was to evaluate the air-blowing temperature and water storage time on the micro-tensile bond strength (μTBS) of five universal adhesive systems to dentin. The bond strength with two different air-blowing temperatures (60±2ºC and 23±2ºC) was measured after water storage at 37ºC for 24 h and 100 days respectively. The fracture surface on dentin side was observed by scanning electron microscope (SEM). Three-way ANOVA revealed a significant effect of universal system (p<0.001) and air-blowing temperature (p<0.001) on bond strength to dentin except water-storage time (p=0.145). The interaction within three factors was significantly different (p<0.001). It could be concluded that the μTBS of universal systems to dentin was material-depended. The higher and more stable bonding performance of universal systems on dentin could be achieved by air-blowing at 60±2ºC temperature. In addition, the quantity of voids in the adhesive layer of aceton-based universal adhesive was significantly reduced by higher temperature.