A dramatic rise in research interest in laser‐induced graphene oxide (GO) reduction and modification requires an overview of the most recent works on this subject. Typical methods for the recognition and confirmation of modified graphene and its derivatives, such as Raman, Fourier‐transform infra‐red (FTIR), X‐ray photoelectron (XP), and ultraviolet‐visible (UV–vis) spectroscopies, are introduced briefly in this review. A major part of the survey is devoted to the main modification ways and the laser parameters used in the literature. A discussion of possible reduction and modification mechanisms is also presented. Recent applications, especially in the biomedical field such as cell therapy treatment, as well as significant results of GO modification, are discussed in detail. Finally, perspectives for the application of laser‐induced GO modifications in passive THz photonics and biomedicine are briefly addressed.
The control of glucose concentration is a crucial factor in clinical diagnosis and the food industry. Electrochemical biosensors based on reduced graphene oxide (rGO) and conducting polymers have a high potential for practical application. A novel thermal reduction protocol of graphene oxide (GO) in the presence of malonic acid was applied for the synthesis of rGO. The rGO was characterized by scanning electron microscopy, X-ray diffraction analysis, Fourier-transform infrared spectroscopy, and Raman spectroscopy. rGO in combination with polyaniline (PANI), Nafion, and glucose oxidase (GOx) was used to develop an amperometric glucose biosensor. A graphite rod (GR) electrode premodified with a dispersion of PANI nanostructures and rGO, Nafion, and GOx was proposed as the working electrode of the biosensor. The optimal ratio of PANI and rGO in the dispersion used as a matrix for GOx immobilization was equal to 1:10. The developed glucose biosensor was characterized by a wide linear range (from 0.5 to 50 mM), low limit of detection (0.089 mM), good selectivity, reproducibility, and stability. Therefore, the developed biosensor is suitable for glucose determination in human serum. The PANI nanostructure and rGO dispersion is a promising material for the construction of electrochemical glucose biosensors.