Hiroto Higa

Dr. Hiroto Higa

Department of Civil Engineering, Estuarine & Coastal Engineering Laboratory, Yokohama National University, Yokohama, Kanagawa 240-8501, Japan

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2017 in Water
Verified
Journal Article
Open access
PDF file
Quang Hao NguyenQuang Hao Nguyen
Quang Hao Nguyen
JSJUN SASAKI
JUN SASAKI
Hiroto HigaHiroto Higa
Hiroto Higa
HHHuan Nguyen Huu
Huan Nguyen Huu
In recent years, seagrass beds in Cam Ranh Bay and Thuy Trieu Lagoon have declined from 800 to 550 hectares, resulting insignificantly reducing the number of fish catch. This phenomenon is due to the effect of the degradation of water environment. Turbidity is one of the most important water quality parameters directly related to underwater light penetration which affects the primary productivity. This study aims to investigate spatiotemporal variation of turbidity in the waters with major factors affecting its patterns using remote sensing data. An algorithm for turbidity retrieval was developed based on the correlation between in situ measurements and a red band of Landsat 8 OLI with R2 = 0.84 (p < 0.05). Simulating WAves Nearshore (SWAN) model was used to compute bed shear stress, a major factor affecting turbidity in shallow waters. In addition, the relationships between turbidity and rainfall, and bed shear stress induced by wind were analyzed. It was found that: (1) In the dry season, turbidity was low at the middle of the bay while it was high in shallow waters nearby coastlines. Resuspension of bed sediment was a major factor controlling turbidity during time with no rainfall. (2) In the rainy season or for a short time after rainfall in the dry season, turbidity was high due to a large amount of runoff entering into the study area.

31 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
SSSalem Ibrahim Salem
Salem Ibrahim Salem
Hiroto HigaHiroto Higa
Hiroto Higa
Hyungjun KimHyungjun Kim
Hyungjun Kim
HKHiroshi Kobayashi
Hiroshi Kobayashi
KOKazuo Oki
Kazuo Oki
TOTaikan Oki
Taikan Oki
Numerous algorithms have been proposed to retrieve chlorophyll-a concentrations in Case 2 waters; however, the retrieval accuracy is far from satisfactory. In this research, seven algorithms are assessed with different band combinations of multispectral and hyperspectral bands using linear (LN), quadratic polynomial (QP) and power (PW) regression approaches, resulting in altogether 43 algorithmic combinations. These algorithms are evaluated by using simulated and measured datasets to understand the strengths and limitations of these algorithms. Two simulated datasets comprising 500,000 reflectance spectra each, both based on wide ranges of inherent optical properties (IOPs), are generated for the calibration and validation stages. Results reveal that the regression approach (i.e., LN, QP, and PW) has more influence on the simulated dataset than on the measured one. The algorithms that incorporated linear regression provide the highest retrieval accuracy for the simulated dataset. Results from simulated datasets reveal that the 3-band (3b) algorithm that incorporate 665-nm and 680-nm bands and band tuning selection approach outperformed other algorithms with root mean square error (RMSE) of 15.87 mg·m−3, 16.25 mg·m−3, and 19.05 mg·m−3, respectively. The spatial distribution of the best performing algorithms, for various combinations of chlorophyll-a (Chla) and non-algal particles (NAP) concentrations, show that the 3b_tuning_QP and 3b_680_QP outperform other algorithms in terms of minimum RMSE frequency of 33.19% and 60.52%, respectively. However, the two algorithms failed to accurately retrieve Chla for many combinations of Chla and NAP, particularly for low Chla and NAP concentrations. In addition, the spatial distribution emphasizes that no single algorithm can provide outstanding accuracy for Chla retrieval and that multi-algorithms should be included to reduce the error. Comparing the results of the measured and simulated datasets reveal that the algorithms that incorporate the 665-nm band outperform other algorithms for measured dataset (RMSE = 36.84 mg·m−3), while algorithms that incorporate the band tuning approach provide the highest retrieval accuracy for the simulated dataset (RMSE = 25.05 mg·m−3).

4 October 2017 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SSSalem Ibrahim Salem
Salem Ibrahim Salem
MSMarie Hayashi Strand
Marie Hayashi Strand
Hiroto HigaHiroto Higa
Hiroto Higa
Hyungjun KimHyungjun Kim
Hyungjun Kim
KKKazuhiro Komatsu
Kazuhiro Komatsu
TOTaikan Oki
Taikan Oki
The chlorophyll-a (Chla) products of seven processors developed for the Medium Resolution Imaging Spectrometer (MERIS) sensor were evaluated. The seven processors, based on a neural network and band height, were assessed over an optically complex water body with Chla concentrations of 8.10–187.40 mg∙m−3 using 10-year MERIS archival data. These processors were adopted for the Ocean and Land Color Instrument (OLCI) sensor. Results indicated that the four processors of band height (i.e. the Maximum Chlorophyll Index (MCI_L1); and Fluorescence Line Height (FLH_L1)); neural network (i.e. Eutrophic Lake (EUL); and Case 2 Regional (C2R)) possessed reasonable retrieval accuracy with root mean square error (R2) in the range of 0.42–0.65. However, these processors underestimated the retrieved Chla > 100 mg∙m−3, reflecting the limitation of the band height processors to eliminate the influence of non-phytoplankton matter and highlighting the need to train the neural network for highly turbid waters. MCI_L1 outperformed other processors during the calibration and validation stages (R2 = 0.65, Root mean square error (RMSE) = 22.18 mg∙m−3, the mean absolute relative error (MARE) = 36.88%). In contrast, the results from the Boreal Lake (BOL) and Free University of Berlin (FUB) processors demonstrated their inadequacy to accurately retrieve Chla concentration > 50 mg∙m−3, mainly due to the limitation of the training datasets that resulted in a high MARE for BOL (56.20%) and FUB (57.00%). Mapping the spatial distribution of Chla concentrations across Lake Kasumigaura using the seven processors showed that all processors—except for the BOL and FUB—were able to accurately capture the Chla distribution for moderate and high Chla concentrations. In addition, MCI_L1 and C2R processors were evaluated over 10-years of monthly measured Chla as they demonstrated the best retrieval accuracy from both groups (i.e. band height and neural network, respectively). The retrieved Chla of MCI_L1 was more accurate at tracking seasonal and annual variation in Chla than C2R, with only slight overestimation occurring during the springtime.

3 June 2017 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SSSalem Ibrahim Salem
Salem Ibrahim Salem
Hiroto HigaHiroto Higa
Hiroto Higa
Hyungjun KimHyungjun Kim
Hyungjun Kim
KKKazuhiro Komatsu
Kazuhiro Komatsu
HKHiroshi Kobayashi
Hiroshi Kobayashi
TOTaikan Oki
Taikan Oki
Many approaches have been proposed for monitoring the eutrophication of Case 2 waters using remote sensing data. Semi-analytical algorithms and spectrum matching are two major approaches for chlorophyll-a (Chla) retrieval. Semi-analytical algorithms provide indices correlated with phytoplankton characteristics, (e.g., maximum and minimum absorption peaks). Algorithms’ indices are correlated with measured Chla through the regression process. The main drawback of the semi-analytical algorithms is that the derived relation is location and data limited. Spectrum matching and the look-up table approach rely on matching the measured reflectance with a large library of simulated references corresponding to wide ranges of water properties. The spectral matching approach taking hyperspectral measured reflectance as an input, leading to difficulties in incorporating data from multispectral satellites. Consequently, multi-algorithm indices and the look-up table (MAIN-LUT) technique is proposed to combine the merits of semi-analytical algorithms and look-up table, which can be applied to multispectral data. Eight combinations of four algorithms (i.e., 2-band, 3-band, maximum chlorophyll index, and normalized difference chlorophyll index) are investigated for the MAIN-LUT technique. In situ measurements and Medium Resolution Imaging Spectrometer (MERIS) sensor data are used to validate MAIN-LUT. In general, the MAIN-LUT provide a comparable retrieval accuracy with locally tuned algorithms. The most accurate of the locally tuned algorithms varied among datasets, revealing the limitation of these algorithms to be applied universally. In contrast, the MAIN-LUT provided relatively high retrieval accuracy for Tokyo Bay (R2 = 0.692, root mean square error (RMSE) = 21.4 mg m−3), Lake Kasumigaura (R2 = 0.866, RMSE = 11.3 mg m−3), and MERIS data over Lake Kasumigaura (R2 = 0.57, RMSE = 36.5 mg m−3). The simulated reflectance library of MAIN-LUT was generated based on inherent optical properties of Tokyo Bay; however, the MAIN-LUT also provided high retrieval accuracy for Lake Kasumigaura. MAIN-LUT could capture the spatial and temporal distribution of Chla concentration for Lake Kasumigaura.

23 October 2021 in Journal of Oceanography
Verified
Journal Article
Closed access
PDF file
Atsushi MatsuokaAtsushi Matsuoka
Atsushi Matsuoka
JCJanet W. Campbell
Janet W. Campbell
SHStanford B. Hooker
Stanford B. Hooker
FSFrançois Steinmetz
François Steinmetz
KOKazunori Ogata
Kazunori Ogata
HMHiroshi Murakami
Hiroshi Murakami

9 January 2025 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SSSalem Ibrahim Salem
Salem Ibrahim Salem
MTMitsuhiro Toratani
Mitsuhiro Toratani
Hiroto HigaHiroto Higa
Hiroto Higa
SeungHyun SonSeungHyun Son
SeungHyun Son
ESEko Siswanto
Eko Siswanto
JIJoji Ishizaka
Joji Ishizaka
The Global Change Observation Mission-Climate (GCOM-C) satellite, launched in December 2017, is equipped with the Second-generation Global Imager (SGLI) sensor, featuring a moderate spatial resolution of 250 m and 19 spectral bands, including the unique 380 nm band. After six years in orbit, a comprehensive evaluation of SGLI products and their temporal consistency is needed. Remote sensing reflectance (Rrs) is the primary product for monitoring water quality, forming the basis for deriving key oceanic constituents such as chlorophyll-a (Chla) and total suspended matter (TSM). The Japan Aerospace Exploration Agency (JAXA) provides Rrs products through two platforms, G-Portal and JASMES, each employing different atmospheric correction methodologies and assumptions. This study aims to evaluate the SGLI full-resolution Rrs products from G-Portal and JASMES at regional scales (Japan and East Asia) and assess G-Portal Rrs products globally between January 2018 and December 2023. The evaluation employs in situ matchups from NASA’s Aerosol Robotic Network-Ocean Color (AERONET-OC) and cruise measurements. We also assess the retrieval accuracy of two water quality indices, Chla and TSM. The AERONET-OC data analysis reveals that JASMES systematically underestimates Rrs values at shorter wavelengths, particularly at 412 nm. While the Rrs accuracy at 412 nm is relatively low, G-Portal’s Rrs products perform better than JASMES at shorter wavelengths, showing lower errors and stronger correlations with AERONET-OC data. Both G-Portal and JASMES show lower agreement with AERONET-OC and cruise datasets at shorter wavelengths but demonstrate improved agreement at longer wavelengths (530 nm, 565 nm, and 670 nm). JASMES generates approximately 12% more matchup data points than G-Portal, likely due to G-Portal’s stricter atmospheric correction thresholds that exclude pixels with high reflectance. In situ measurements indicate that G-Portal provides better overall agreement, particularly at lower Rrs magnitudes and Chla concentrations below 5 mg/m3. This evaluation underscores the complexities and challenges of atmospheric correction, particularly in optically complex coastal waters (Case 2 waters), which may require tailored atmospheric correction methods different from the standard approach. The assessment of temporal consistency and seasonal variations in Rrs data shows that both platforms effectively capture interannual trends and maintain temporal stability, particularly from the 490 nm band onward, underscoring the potential of SGLI data for long-term monitoring of coastal and oceanic environments.