Wei Xiao

Mr. Wei Xiao


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2015 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
QFQiangqiang Fu
Qiangqiang Fu
HLHongwu Liu Liu
Hongwu Liu Liu
ZWZe Wu
Ze Wu
ALAn Liu
An Liu
CYCuize Yao
Cuize Yao
YTYong Tang
Yong Tang
Immunochromatographic sensors (ICSs) are inexpensive, simple, portable, and robust, thus making ICSs commonplace in clinical diagnoses, food testing, and environmental monitoring. However, commonly used gold nanoparticles (AuNPs) ICSs have low sensitivity. Therefore, we developed highly sensitive surface enhanced Raman scattering (SERS) ICSs. To enhance the sensitivity of SERS ICSs, rough surface core–shell Au@Ag nanoparticles (RSAu@AgNPs) were prepared by coating silver on the surface of gold nanoflowers (AuNFs). Then these nanoparticles were used as SERS substrate in the SERS ICSs, after which the SERS ICSs were implemented to detect haemoglobin and heavy metal cadmium ion (Cd2+). The limit of detection (LOD) of the SERS ICSs for detecting haemoglobin was 8 ng/mL, and the linear range of the SERS ICSs was from 31.3 to 2000 ng/mL. The LOD of the SERS ICSs for detecting Cd2+ was 0.05 ng/mL and the linear analysis range was from 0.05 to 25 ng/mL. The cross reactivity of the SERS ICSs was studied and results showed that the SERS ICSs exhibited highly specific for detection of haemoglobin and Cd2+, respectively. The SERS ICSs were then used to detect haemoglobin (spiked in serum and in stool) and Cd2+ (spiked in tap water, river water, and soil leaching water), and the results showed high recovery. These characteristics indicated that SERS ICSs were ideal tools for clinical diagnosis and environmental pollution monitoring.

5 December 2018 in Discover Nano
Verified
Journal Article
Open access
PDF file
QYQuanli Yang
Quanli Yang
RCRuitian Cai
Ruitian Cai
WXWei Xiao
Wei Xiao
ZWZengfeng Wu
Zengfeng Wu
XLXia Liu
Xia Liu
JXJunjian Xiang
Junjian Xiang
Serum myoglobin is one of the earliest markers for the diagnosis of acute myocardial infarction. It is, therefore, critical to develop a point-of-care testing technology for myoglobin detection. In this work, we reported a sensitive plasmonic immunoassay-based on enzyme-mediated localized surface plasmon resonance change of gold nanorods for the point-of-care testing detection of myoglobin. In addition, we developed a novel plasmonic immunoassay reader using the ambient light sensor of smart phone to increase the accessibility and utility of the plasmonic immunoassay. The linear detection range of gold nanorods-based plasmonic immunoassay for myoglobin detection was 0.1–1000 ng mL−1 and the limit of detection was 0.057 ng mL−1. Myoglobin in serum samples was also analyzed by the plasmonic immunoassay. The results were significantly correlated with those of conventional enzyme-linked immunosorbent assay. The plasmonic immunoassay, coupled with smart phone-based reader, could be widely used for point-of-care testing application of acute myocardial infarction, especially in the regions with limited technological resources.