Tian Xia

Dr. Tian Xia

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2019 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
TXTian Xia
Tian Xia
AKAbby Kleinheksel
Abby Kleinheksel
ELEric M. Lee
Eric M. Lee
ZQZhong Qiao
Zhong Qiao
KWKrista R. Wigginton
Krista R. Wigginton
HCHerek L. Clack
Herek L. Clack
Outbreaks of airborne infectious diseases such as measles or severe acute respiratory syndrome can cause significant public alarm. Where ventilation systems facilitate disease transmission to humans or animals, there exists a need for control measures that provide effective protection while imposing minimal pressure differential. In the present study, viral aerosols in an airstream were subjected to non-thermal plasma (NTP) exposure within a packed-bed dielectric barrier discharge reactor. Comparisons of plaque assays before and after NTP treatment found exponentially increasing inactivation of aerosolized MS2 phage with increasing applied voltage. At 30 kV and an air flow rate of 170 standard liters per minute, a greater than 2.3 log reduction of infective virus was achieved across the reactor. This reduction represented ~2 log of the MS2 inactivated and ~0.35 log physically removed in the packed bed. Increasing the air flow rate from 170 to 330 liters per minute did not significantly impact virus inactivation effectiveness. Activated carbon-based ozone filters greatly reduced residual ozone, in some cases down to background levels, while adding less than 20 Pa pressure differential to the 45 Pa differential pressure across the packed bed at the flow rate of 170 standard liters per minute.

1 July 2020 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
TXTian Xia
Tian Xia
MYM. Yang
M. Yang
IMI. Marabella
I. Marabella
ELE.M. Lee
E.M. Lee
BOB. Olson
B. Olson
HCH.L. Clack
H.L. Clack

18 June 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
EOEduardo (Jay) Olaguer
Eduardo (Jay) Olaguer
SJShelley Jeltema
Shelley Jeltema
TGThomas Gauthier
Thomas Gauthier
DJDustin Jermalowicz
Dustin Jermalowicz
AOArthur Ostaszewski
Arthur Ostaszewski
JZJoyce Zhu
Joyce Zhu
Municipal solid waste landfills are significant sources of atmospheric methane, the second most important greenhouse gas after carbon dioxide. Large emissions of methane from landfills contribute not only to global climate change, but also to local ozone formation due to the enhancement of radical chain lengths in atmospheric reactions of volatile organic compounds and nitrogen oxides. Several advanced techniques were deployed to measure methane emissions from two landfills in the Southeast Michigan ozone nonattainment area during the Michigan–Ontario Ozone Source Experiment (MOOSE). These techniques included mobile infrared cavity ringdown spectrometry, drone-mounted meteorological sensors and tunable diode laser spectrometry, estimation of total landfill emissions of methane based on flux plane measurements, and Gaussian plume inverse modeling of distributed methane emissions in the presence of complex landfill terrain. The total methane emissions measured at the two landfills were of the order of 500 kg/h, with an uncertainty of around 50%. The results indicate that both landfill active faces and leaking gas collection systems are important sources of methane emissions.

12 December 2020 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
TXTian Xia
Tian Xia
JCJames Catalan
James Catalan
CHChris Hu
Chris Hu
Stuart BattermanStuart Batterman
Stuart Batterman

3 October 2024 in Frontiers in Public Health
Verified
Journal Article
Open access
PDF file
TXTian Xia
Tian Xia
JRJulia Raneses
Julia Raneses
BSBrixon Schmiesing
Brixon Schmiesing
RGRaquel Garcia
Raquel Garcia
AWAlison Walding
Alison Walding
SBStuart A. Batterman
Stuart A. Batterman
Introduction: Many school buildings have inadequate ventilation, rudimentary if any air filtration, and aging and poorly maintained mechanical systems, all of which can lead to poor indoor air quality (IAQ). These issues are especially acute in environmental justice (EJ) communities where schools are located in polluted areas. This community-based participatory research examines how IAQ in naturally ventilated school buildings is affected by the use of air purifiers, air change rates, outdoor pollution levels, and teacher and staff behavior.Methods: IAQ assessments were performed at two schools in Detroit, Michigan, which included building walk-through inspections and continuous indoor and outdoor measurements of black carbon (BC), particulate matter (PM10 and PM2.5), carbon dioxide (CO2), air change rates (ACRs), temperature, humidity, and sound pressure levels. Air purifiers with usage monitors were then installed, and the IAQ assessments were repeated. Teachers were surveyed before and after purifier deployment.Results: At baseline, classrooms had low ACRs (0.58–1.38 h−1), moderate PM2.5 levels (2.8–8.9 μg/m3), highly variable PM10 concentrations (4.7–37.5 μg/m3), and elevated BC levels (0.3–0.7 μg/m3), reflecting emissions from local traffic, industry and other sources. The installation and use of purifiers reduced pollutant levels and the overall performance matched the predictions of a single compartment model. However, daily reductions varied widely among classrooms, reflecting differences in teacher behavior regarding the frequency of opening windows and the operation of purifiers, including differences in purifier fan speed settings and whether purifiers were used at night. Survey responses indicated that many teachers were aware of IAQ problems. The higher rates reported for health symptoms and dissatisfaction at one school may have lowered the teachers’ tolerance to noise and reduced purifier use.Discussion: The study helps explain the variation reported in prior studies using purifiers, and it reinforces the need to monitor IAQ and purifier use, use enhanced filtration and increase ventilation, and engage with teachers and school staff to support and maintain IAQ programs in schools.

23 May 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
TXTian Xia
Tian Xia
SBSachraa G Borjigin
Sachraa G Borjigin
JRJulia Raneses
Julia Raneses
CSCraig Stroud
Craig Stroud
Stuart BattermanStuart Batterman
Stuart Batterman
Municipal solid waste landfills are major contributors to anthropogenic emissions of methane (CH4), which is the major component of natural gas, a potent greenhouse gas, and a precursor for the formation of tropospheric ozone. The development of sensitive, selective, and fast-response instrumentation allows the deployment of mobile measurement platforms for CH4 measurements at landfills. The objectives of this study are to use mobile monitoring to measure ambient levels of CH4 at eight large operating landfills in southeast Michigan, USA; to characterize diurnal, daily and spatial variation in CH4 levels; and to demonstrate the influence of meteorological factors. Elevated CH4 levels were typically found along the downwind side or corner of the landfill. Levels peaked in the morning, reaching 38 ppm, and dropped to near-baseline levels during midday. Repeat visits showed that concentrations were highly variable. Some variation was attributable to the landfill size, but both mechanistically-based dilution-type models and multivariate models identified that wind speed, boundary layer height, barometric pressure changes, and landfill temperature were key determinants of CH4 levels. Collectively, these four factors explained most (r2 = 0.89) of the variation in the maximum CH4 levels at the landfill visited most frequently. The study demonstrates the ability to assess spatial and temporal variation in CH4 levels at landfills using mobile monitoring along perimeter roads. Such monitoring can identify the location of leaks and the best locations for long-term emission monitoring using fixed site monitors.