Mustafa Dolaz

Prof. Dr. Mustafa Dolaz

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Process Biochemistry
Verified
Journal Article
Closed access
MKMelike Kozak
Melike Kozak
KCKevser Cırık
Kevser Cırık
MDMustafa Dolaz
Mustafa Dolaz
SBSerden Başak
Serden Başak

1 March 2022 in Cellulose Chemistry and Technology
Verified
Journal Article
Open access
NÇNuran Çelikçi
Nuran Çelikçi
CZCengiz Ayhan Ziba
Cengiz Ayhan Ziba
MDMustafa Dolaz
Mustafa Dolaz
This study aimed at the recovery of cellulose from abundantly available wastes and its sustainable application. Firstly, in the cleaning process, cellulose-containing wastes, such as “air particle vacuum powder” (APVD), “towel clippings” (TC), and “cottonseed delintation residues” (CD), were thoroughly washed, separately, with tap water to remove some organic and inorganic impurities. The cotton slurry was purified by 17.5% NaOH at 90 oC for about 4 hours, then filtered and washed with tap water. Afterwards, the resulting pulp was bleached by NaOH and H2O2, and washed with distilled water until neutralized. Secondly, for the synthesis of carboxymethyl cellulose (CMC) from the above-dried celluloses, optimum conditions were achieved by varying the concentrations of components and ambient conditions. In the sample coded TCCMC3, a maximum degree substitution (DS) of 1.22, the highest consistency, the highest penetration time and the highest viscosity with 2520 centipoises (cP) were obtained from the reaction of towel clippings with 5.62 g sodium hydroxide and 13.12 g monochloroacetic acid (MCA) at 65 oC for 3 hours. Finally, the effect of these synthesized CMCs on the consistency and penetration time of a cement paste was investigated. The consistency of standard Portland cement (PC), without CMC addition, was 5 mm in the Vicat test, while the values measured for the cement pastes to which TCCMC3, APVDCMC3 and CDCMC3 were added reached 36.5 mm, 28.0 mm and 13.0 mm, respectively. While the setting time in the standard sample (Portland cement paste, PCP) was between 2.20-4.10 hours, this time shifted to 3.30-7.00 hours, with a maximum setting time recorded with the addition of TCCMC3. Besides, while the penetration time for APVDCMC3 started at 3.10 hours and was completed at 5.30 hours, for CDCMC3, it ranged between 2.40 and 4.40 hours, leaving it without hydration in a higher time interval than in the case of standard Portland cement paste. As a result, it has been found that carboxymethyl cellulose synthesized by the etherification reaction of cellulose obtained from recycled wastes for industrial uses, in an aqueous alkali environment, can be applied as a thickener in the construction industry and other fields.

1 August 2006 in Transition Metal Chemistry
Verified
Journal Article
Closed access
PDF file
AGAybegül Gölcü
Aybegül Gölcü
MDMustafa Dolaz
Mustafa Dolaz
HDHavva Demirelli
Havva Demirelli
MDMetin Diðrak
Metin Diðrak
SSSelahattin Serin
Selahattin Serin

4 January 2024 in Journal of Chromatography A
Verified
Journal Article
Closed access
MKMehmet Kobya
Mehmet Kobya
MDMustafa Dolaz
Mustafa Dolaz
AGAysegul Yagmur Goren
Aysegul Yagmur Goren

2 September 2022 in Heliyon
Verified
Journal Article
Open access
MKMehmet Kobya
Mehmet Kobya
MDMustafa Dolaz
Mustafa Dolaz
BÖBurcu Özaydın-Şenol
Burcu Özaydın-Şenol
AGAysegul Yagmur Goren
Aysegul Yagmur Goren
Electrocoagulation (EC) is a significantly efficient method for As removal from waters and received considerable attention recently. In this study, the natural groundwater (GW) samples containing As concentrations of GW-1: 538.8 μg L−1, GW-2: 1132.1 μg L−1, and GW-3: 52, 000 μg L−1 were obtained from different provinces and treated by EC process using different iron anodes (plate, ball, and scrap). To achieve drinking water As standard (10 μg L−1), the operational time, applied current, and As removal optimization for all anode types were studied. At applied current of 0.025 A, the As removal efficiency, EC time, and operating cost were >99.9%, 180 min and 0.406 $ m−3 for ball anodes, >99.9%, 100 min and 0.0813 $ m−3 for plate anodes, >99.9%, 80 min and 0.0815 $ m−3 for scrap anodes for GW-3, respectively. It was observed that as the As concentration in the GW increased, the EC time and operating cost increased. Overall, it was concluded that Fe scrap anodes are more advantageous than other types of anodes in terms of operating cost in EC reactor for As removal.

19 January 2021 in Journal of Polymers and the Environment
Verified
Journal Article
Closed access
PDF file
GGGökhan Gönül
Gökhan Gönül
NCNuran Celikci
Nuran Celikci
CZCengiz Ayhan Ziba
Cengiz Ayhan Ziba
MDMustafa Dolaz
Mustafa Dolaz