javier de lucas

Dr. javier de lucas

National Institute for Aerospace Technology, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2015 in Metrologia
Verified
Journal Article
Closed access
JLjavier de lucas
javier de lucas
JSJosé Juan Segovia
José Juan Segovia
A numerical and geometrical model for calculating the local effective emissivity of isothermal blackbody cylinder-conical cavities with lid, assuming diffuse reflection, is described. This has been developed by generalizing previous models based on conical and cylindrical geometries. The model has been validated by determining the diffusely reflected photon trajectories and the corresponding experimental view factors between given pairs of surface elements. Differences compared to theoretical values, were subsequently analyzed in terms of the model’s intrinsic uncertainty. A well-defined numerical function that calculates the effective emissivity as a function of its natural variables, intrinsic emissivity and geometrical parameters, is established. In order to calculate the probability distribution of the output quantity, we use the Monte Carlo method for the propagation of the probability distributions that characterize our knowledge concerning the values of the influence variables. The model is applied to heat-pipe black bodies installed at our laboratory, previously characterized at the PTB. A comparison with published uncertainty results, obtained by applying classical uncertainty propagation techniques, is also made.

15 October 2014 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
JLjavier de lucas
javier de lucas

24 March 2018 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
JLjavier de lucas
javier de lucas
JSJosé Juan Segovia
José Juan Segovia


12 August 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
José L. BalenzateguiJosé L. Balenzategui
José L. Balenzategui
JLjavier de lucas
javier de lucas
JCJose Cuenca
Jose Cuenca
AGA González-Leiton
A González-Leiton
MMM Molero
M Molero
EPE Prieto
E Prieto
Solar-type cavity radiometers are instruments of the highest metrological level for measuring solar direct normal irradiance. To ensure their traceability and performance, they are periodically compared to the World Group of Standards, which realizes the World Radiometric Reference (WRR), in the International Pyrheliometer Comparisons (IPCs). Additionally, they can be characterized in an absolute way, with direct traceability to SI units and with their measurement uncertainty calculated. This paper describes the different techniques and procedures applied for the characterization and calibration of solar cavity radiometers, with the main results obtained to date in the case of an Automatic Hickey–Frieden (AHF) radiometer. Voltmeters, resistors, temperature sensors and the area of the precision apertures have been calibrated, while the effective absorptance, temperature coefficients, optical scattering and non-equivalence factor have been evaluated. The temperature dependence of the electrical current in the cavity heater has also been analysed. The resulting corrections obtained for the AHF by characterization are compatible with the WRR factors obtained by this instrument in the past IPCs. An uncertainty of 0.42% ( k = 1) has been obtained, and this paper discusses further improvements that may be able to reduce this figure to the desired expanded uncertainty of U = 0.1% ( k = 2).

1 August 2015 in Metrologia
Verified
Journal Article
Closed access
JLjavier de lucas
javier de lucas
In this paper, a geometrical model for the numerical calculation of the integrated effective emissivity of conical isothermal cavities with a lid, is described in detail. We make use of the Montecarlo method and the ‘back ray tracing’ technique, assuming diffuse reflection and a detector situated at an arbitrary distance from the cavity aperture. First, the geometry of the problem is discussed and the local hemispherical emissivity profiles along the cone generatrix are calculated for different configurations. Then we proceed to the validation of the model, by calculating the distribution of the reflected photons in the interior of the cavity, such as it is provided by the numerical algorithm. The calculated distribution is compared with theoretical values, obtained from the expressions of the view factors for the conical geometry. The calculated values for the local and integrated effective emissivity are compared with results published by other authors, highlighting the differences between them, and the internal consistency of our model is demonstrated. Special attention to the calculation of the view factors in conical cavities affected by vignetting due to the obstruction produced by the lid, is paid. The view factors of points at the penumbral region are numerically calculated, applying the Montecarlo method, including a complete analysis of the uncertainty.