Zhenyi Shao

Dr. Zhenyi Shao


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2017 in Discover Nano
Verified
Journal Article
Open access
PDF file
XJXiaosong Jiang
Xiaosong Jiang
TSTingfeng Song
Tingfeng Song
ZSZhenyi Shao
Zhenyi Shao
WLWanxia Liu
Wanxia Liu
DZDegui Zhu
Degui Zhu
MZMinhao Zhu
Minhao Zhu
Multi-walled carbon nanotubes (MWCNTs) and graphenes have been taken for novel reinforcements due to their unique structure and performance. However, MWCNTs or graphenes reinforced copper matrix composites could not catch up with ideal value due to reinforcement dispersion in metal matrix, wettability to metal matrix, and composite material interface. Taking advantage of the superior properties of one-dimensional MWCNTs and two-dimensional graphenes, complementary performance and structure are constructed to create a high contact area between MWCNTs and graphenes to the Cu matrix. Mechanical alloying, hot pressing, and hot isostatic pressing techniques are used to fabricate Cu matrix self-lubricating nanocomposites. Effects of MWCNTs and graphenes on mechanical properties and microstructures of Cu/Ti3SiC2/C nanocomposites are studied. The fracture and strengthening mechanisms of Cu/Ti3SiC2/C nanocomposites are explored on the basis of structure and composition of Cu/Ti3SiC2/C nanocomposites with formation and function of interface.

11 June 2018 in Materials
Verified
Journal Article
Open access
PDF file
GZGuihang Zhang
Guihang Zhang
XJXiaosong Jiang
Xiaosong Jiang
CQChangJun Qiao
ChangJun Qiao
ZSZhenyi Shao
Zhenyi Shao
DZDegui Zhu
Degui Zhu
VVVictor Valcarcel
Victor Valcarcel
Single-crystal α-Al2O3 fibres can be utilized as a novel reinforcement in high-temperature composites owing to their high elastic modulus, chemical and thermal stability. Unlike non-oxide fibres and polycrystalline alumina fibres, high-temperature oxidation and polycrystalline particles boundary growth will not occur for single-crystal α-Al2O3 fibres. In this work, single-crystal α-Al2O3 whiskers and Al2O3 particles synergistic reinforced copper-graphite composites were fabricated by mechanical alloying and hot isostatic pressing techniques. The phase compositions, microstructures, and fracture morphologies of the composites were investigated using X-ray diffraction, a scanning electron microscope equipped with an X-ray energy-dispersive spectrometer (EDS), an electron probe microscopic analysis equipped with wavelength-dispersive spectrometer, and a transmission electron microscope equipped with EDS. The mechanical properties have been measured by a micro-hardness tester and electronic universal testing machine. The results show that the reinforcements were unevenly distributed in the matrix with the increase of their content and there were some micro-cracks located at the interface between the reinforcement and the matrix. With the increase of the Al2O3 whisker content, the compressive strength of the composites first increased and then decreased, while the hardness decreased. The fracture and strengthening mechanisms of the composite materials were explored on the basis of the structure and composition of the composites through the formation and function of the interface. The main strengthening mechanism in the composites was fine grain strengthening and solid solution strengthening. The fracture type of the composites was brittle fracture.

9 August 2018 in Materials
Verified
Journal Article
Open access
PDF file
FLFeng Li
Feng Li
XJXiaosong Jiang
Xiaosong Jiang
ZSZhenyi Shao
Zhenyi Shao
DZDegui Zhu
Degui Zhu
Zhiping LuoZhiping Luo
Zhiping Luo
Titanium alloy/Hydroxyapatite (HA) composites have become a hot research topic in biomedical materials, while there are some challenges concerning bioactivity and mechanical properties such as low interface adhesion at the interface between metal and ceramic, complex interfacial reactions, and so on. Nevertheless, composites with reinforced phases can reach special properties that meet the requirements of biomedical materials due to the strong interfacial interactions between reinforcing phases (nano-carbon, partial oxides, and so on) and Titanium alloys or HA. This review summarizes the interface properties and mechanisms of Titanium alloy/HA composites, including interfacial bonding methods, strengthening and toughening mechanisms, and performance evaluation. On this basis, the interface characteristics and mechanisms of the Titaniumalloy/HA composites with enhanced phase are prospected. The results show that the interfacial bonding methods in the Titanium alloy/HA composites include chemical reactions and mechanical effects. The strengthening and toughening mechanisms contain grain refinement strengthening, second phase strengthening, solution strengthening, cracks and pulling out mechanisms, etc. This review provides a guidline for the fabrication of biocomposites with both mechanical properties and bioactivity.

3 November 2016 in Metals
Verified
Journal Article
Open access
PDF file
TSTingfeng Song
Tingfeng Song
XJXiaosong Jiang
Xiaosong Jiang
ZSZhenyi Shao
Zhenyi Shao
DMDefeng Mo
Defeng Mo
DZDegui Zhu
Degui Zhu
MZMinhao Zhu
Minhao Zhu
316L stainless steel (Fe–18Cr–11Ni) and a Kovar (Fe–29Ni–17Co or 4J29) alloy were diffusion-bonded via vacuum hot-pressing in a temperature range of 850–950 °C with an interval of 50 °C for 120 min and at 900 °C for 180 and 240 min, under a pressure of 34.66 MPa. Interfacial microstructures of diffusion-bonded joints were characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), and energy dispersive spectroscopy (EDS). The inter-diffusion of the elements across the diffusion interface was revealed via electron probe microanalysis (EPMA). The mechanical properties of the joints were investigated via micro Vickers hardness and tensile strength. The results show that an Ni interlayer can serve as an effective diffusion barrier for the bonding of 316L stainless steel and the 4J29 Kovar alloy. The composition of the joints was 316L/Ni s.s (Fe–Cr–Ni)/remnant Ni/Ni s.s (Fe–Co–Ni)/4J29. The highest tensile strength of 504.91 MPa with an elongation of 38.75% was obtained at 900 °C for 240 min. After the width of nickel solid solution (Fe–Co–Ni) sufficiently increased, failure located at the 4J29 side and the fracture surface indicated a ductile nature.

7 April 2022 in ACS Applied Energy Materials
Verified
Journal Article
Closed access
DCDe Ping Chen
De Ping Chen
LYLei Yuan
Lei Yuan
MLMeng Jue Li
Meng Jue Li
WHWen Jing Han
Wen Jing Han
XLXu Dong Liu
Xu Dong Liu
CWChao Yang Wang
Chao Yang Wang

15 September 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
FLFeng Li
Feng Li
XJXiaosong Jiang
Xiaosong Jiang
ZSZhenyi Shao
Zhenyi Shao
DZDegui Zhu
Degui Zhu
Zhiping LuoZhiping Luo
Zhiping Luo
Nano-carbon reinforced titanium matrix/hydroxyapatite (HA) biocomposites were successfully prepared by spark plasma sintering (SPS). The microstructure, mechanical properties, biocompatibility, and the relationship between microstructure and properties of biocomposites were systematically investigated. Results showed there are some new phases in sintered composites, such as β-Ti, TiO3, ZrO2, etc. Moreover, a small amount of Ti17P10, CaTiO3, Ca3(PO4)2 were also detected. The reaction that may occur during the preparation process is suppressed to some extent, which is because that the addition of second phases can prevent the direct contact of titanium with HA and reduce the contact areas. Transmission electron microscope (TEM) analysis proved the existence of elemental diffusion and chemical reactions in sintered composites. Compared with results of composites prepared by hot-pressed sintering before, mechanical properties (microhardness, compressive strength, and shear strength) of 0.5-GNFs composites prepared by SPS were increased by about 2.8, 4.8, and 4.1 times, respectively. The better mechanical properties of 0.5-GNFs composite in nano-carbon reinforced composites are mainly due to the lower degree of agglomeration of tubular carbon nanotubes (CNTs) compared to lamellar graphene nanoflakes (GNFs). Moreover, the strengthening and toughening mechanisms of nano-carbon reinforced titanium alloy/HA biocomposite prepared by spark plasma sintering (SPS) mainly included second phase strengthening, grain refinement strengthening, solution strengthening, graphene extraction, carbon nanotubes bridging, crack tail stripping, etc. In addition, in vitro bioactivity test revealed that the addition of nano-carbon was beneficial to promote the adhesion and proliferation of cells on the surface of titanium alloy/HA composite, because nano-carbon can enhance the formation of mineralized necks in the composites after transplantation, stimulate biomineralization and promote bone regeneration.