Outdoor wind and thermal environments in residential areas are greatly affected by the distance between buildings. A short distance is conducive to providing shade, and a long distance can enhance ventilation between buildings. In this study, four cities with different latitudes in China (Guangzhou, Wuhan, Beijing, and Harbin) were selected to research the relationship between the distance between buildings and thermal environments of residential areas. The results show that (1) when the distance between buildings is small, it is easier for wind paths to form. Wind paths can strengthen the wind velocity. When the distance between buildings exceeds 40–50 m, the building density is small, the building’s resistance to the wind becomes smaller and smaller, and the wind speed will gradually increase. (2) When the distance is in the range of 20–50 m, the MRT (mean radiant temperature) rise rate of each city is similar. For every 10 m increase in the distance between buildings, the MRT increases by about 1.25 °C. (3) D = 50 m (D/H = 1.19) is an inflection point. When D is less than 50 m, within the range of 20–50 m, the smaller the D is, the lower the SET* (standard effective temperature) is, while when D is more than 50 m, the opposite trend is observed.
Currently, people in crowded indoor spaces are required to wear a variety of personal protective equipment to curb the spread of COVID-19. This study aimed to investigate the effects of wearing four types of personal protective equipment (unprotected, wearing masks, wearing face shield and wearing medical protective clothing) on human thermal perception and physiological responses in indoor crowded spaces in summer. The experiment was conducted in a climate chamber designed to simulate the indoor crowded spaces. Environmental parameters of climate chamber (air temperature, relative humidity and wind speed), physiological parameters of subjects (wrist skin temperature and pulse rate), and subjective perceptions (thermal sensation and thermal comfort) were collected during the experiment. The experimental results showed that medical protective clothing has the most obvious blocking effect on heat exchange between human and environment. Thermal sensation in state 4 (wearing medical protective clothing) was significantly (p < 0.05) higher than that in other states. The study of physiological parameters showed that the wrist skin temperature and pulse rate under different protection states increased with the increase of room temperature. Through regression analysis, the thermal sensation estimation model of protective personnel in indoor crowded spaces based on wrist skin temperature and pulse rate was established. The adjusted R2 and RMSE of all models were above 82% and less than 1, indicating that the established thermal sensation model had a good prediction effect.
There has been an insufficient study of passive climate adaptability that considers both the summer and winter season for the outdoor thermal environment of hot-summer and cold-winter cities. In this study, we performed a quantitative simulation to research the passive climate adaptability of a residential area, considering piloti as the main method for climate adaptation in a hot-summer and cold-winter city in China. Numerical simulations were performed with a coupled simulation method of convection, radiation, and conduction. A cubic non-linear k–ε model proposed by Craft et al. was selected as the turbulence model and three-dimensional multi-reflections of shortwave and longwave radiations were considered in the radiation simulation. Through the simulation, we found that setting the piloti at the two ends of the building was the optimal piloti arrangement for climate adaptation. Then the relationship between the piloti ratio (0%, 20%, 40%, 60%, and 80%) and the outdoor thermal environment was studied. It could be concluded that with the increasing piloti ratio, the wind velocity increased, the mean radiant temperature (MRT) decreased slightly, and the average standard effective temperature (SET*) decreased to 3.6 °C in summer, while in winter, with the increasing piloti ratio, the wind velocity, MRT, and SET* changed slightly. The wind environment significantly affected the SET* value, and the piloti ratio should be between 12% and 38% to avoid wind-induced discomfort.
With the increasing of building energy consumptions, the related issues of energy crisis and environmental pollution become more and more prominent. As an effective energy-saving technology, the passive house (PH) has been widely applied in China to reduce the building energy utilization. However, the design and application of PH vary with different climate conditions. Therefore, it is significant to conduct the parameterization of PH and propose a suitable design zoning of PH in China. In our study, a comprehensive feasibility analysis of the implementation of PH is performed, which chooses 31 representative cities covering 5 climatic regions. The sensitivity analysis firstly filters the key parameters that heavily affect energy consumption. The results indicate that the key parameters include external wall heat transfer coefficient (WU), basement ceiling heat transfer coefficient (BCU), solar heat gain coefficient (SHGC), glass G value (UG), heat recovery efficiency (HERE) and humidity recovery efficiency (HURE). Then, with the multiple regression approach, the values of key parameters are optimized. Based on the determined values of sensitive parameters, the design zoning of PH in China is finally proposed, which can guide the design of PH as well as enhance the application of PH in China.