Daniel Portillo

Dr. Daniel Portillo

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2022 in Prehospital and Disaster Medicine
Verified
Journal Article
Closed access
PDF file
CNCraig D. Nowadly
Craig D. Nowadly
DPDaniel Portillo
Daniel Portillo
MDMaxwell L. Davis
Maxwell L. Davis
RHR. Lyle Hood
R. Lyle Hood
RLRobert A. De Lorenzo
Robert A. De Lorenzo
Introduction: Portable oxygen concentrators (POCs) are medical devices that use physical means to separate oxygen from the atmosphere to produce concentrated, medical-grade gas. Providing oxygen to low-resources environments, such as austere locations, military combat zones, rural Emergency Medical Services (EMS), and during disasters, becomes expensive and logistically intensive. Recent advances in separation technology have promoted the development of POC systems ruggedized for austere use. This review provides a comprehensive summary of the available data regarding POCs in these challenge environments.Methods: PubMed, Google Scholar, and the Defense Technical Information Center were searched from inception to November 2021. Articles addressing the use of POCs in low-resource settings were selected. Three authors were independently involved in the search, review, and synthesis of the articles. Evidence was graded using Oxford Centre for Evidence-Based Medicine guidelines.Results: The initial search identified 349 articles, of which 40 articles were included in the review. A total of 724 study subjects were associated with the included articles. There were no Level I systematic reviews or randomized controlled trials.Discussion: Generally, POCs are a low-cost, light-weight tool that may fill gaps in austere, military, veterinary, EMS, and disaster medicine. They are cost-effective in low-resource areas, such as rural and high-altitude hospitals in developing nations, despite relatively high capital costs associated with initial equipment purchase. Implementation of POC in low-resource locations is limited primarily on access to electricity but can otherwise operate for thousands of hours without maintenance. They provide a unique advantage in combat operations as there is no risk of explosive if oxygen tanks are struck by high-velocity projectiles. Despite their deployment throughout the battlespace, there were no manuscripts identified during the review involving the efficacy of POCs for combat casualties or clinical outcomes in combat. Veterinary medicine and animal studies have provided the most robust data on the physiological effectiveness of POCs. The success of POCs during the coronavirus disease 2019 (COVID-19) pandemic highlights the potential for POCs during future mass-casualty events. There is emerging technology available that combines a larger oxygen concentrator with a compressor system capable of refilling small oxygen cylinders, which could transform the delivery of oxygen in austere environments if ruggedized and miniaturized. Future clinical research is needed to quantify the clinical efficacy of POCs in low-resource settings.

21 July 2022 in Fluids
Verified
Journal Article
Open access
PDF file
DPDaniel Portillo
Daniel Portillo
EHEugene Hoffman
Eugene Hoffman
MGMatt Garcia
Matt Garcia
ELElijah LaLonde
Elijah LaLonde
CCChristopher Combs
Christopher Combs
RHR. Lyle Hood
R. Lyle Hood
Investigations of fluidic oscillators, or sweeping jet actuators, have primarily been conducted within the incompressible flow regime, which limits the accuracy of estimating fluidic oscillator performance for compressible flows. The objective of this study was to evaluate the effects of gas compressibility on the performance of a fluidic oscillator. A commonly used fluidic oscillator geometry (the Bray geometry) was scaled to five different sizes, 3D printed, and tested over a range of air flow rates. High-speed Schlieren images captured the sweeping jet exiting the fluidic oscillators, and custom MATLAB algorithms were used to calculate the oscillation frequencies and angles. A spectral proper orthogonal decomposition (SPOD) method was used to identify and compare the mode structures within the flow fields. All the results were compared using dimensionless parameters to observe performance trends. The results showed that the oscillation frequencies were directly proportional to the flow rate, while the oscillation angles were inversely proportional to the flow rate, regardless of scale size. The angular velocities were not proportional to the flow rate or scale size and exhibited maxima within the evaluated ranges. For all scale sizes, the mode structures were symmetric across the centerlines of the fluidic oscillators and extended further beyond the fluidic oscillators at higher flow rates. These results enable the prediction of fluidic oscillator performance, which can significantly improve the design process for an application where a fluidic oscillator may be used, such as aerospace applications, power generation, heat exchangers, or medical devices.

19 August 2021 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
DPDaniel Portillo
Daniel Portillo
LBLauren Bayliss
Lauren Bayliss
SRStephen Rivas
Stephen Rivas
GPGabriela Pineda
Gabriela Pineda
SKSukhwinder Kaur
Sukhwinder Kaur
RHR. Lyle Hood
R. Lyle Hood

1 June 2022 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
DPDaniel Portillo
Daniel Portillo
JGJose Gonzalez
Jose Gonzalez
CVCarorina Villarreal
Carorina Villarreal
SSSophia J. Salazar
Sophia J. Salazar
AFAnjelyka Fasci
Anjelyka Fasci
RHR. Lyle Hood
R. Lyle Hood

20 December 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
JGJose Manuel Gonzalez
Jose Manuel Gonzalez
CVCarorina Villarreal
Carorina Villarreal
AFAnjelyka Fasci
Anjelyka Fasci
DRDavid Di Rocco
David Di Rocco
SSSophia Salazar
Sophia Salazar
RHR. Lyle Hood
R. Lyle Hood
Introduction: On the United States’ Organ Transplantation Waitlist, approximately 17 people die each day waiting for an organ. The situation continues to deteriorate as the discrepancy between harvested organs and the number of patients in need is increasing. Static cold storage is the clinical standard method for preserving a harvested organ but is associated with several drawbacks. Machine perfusion of an organ has been shown to improve preservation quality as well as preservation time over static cold storage. While there are machine perfusion devices clinically available, they are costly and limited to specific organs and preservation solutions. This study presents a versatile oxygenating perfusion system (VOPS) that supplies oxygen and pulsatile perfusion. Materials and Methods: Experiments evaluated the system’s performance with a human kidney mimicking hydraulic analog using multiple compressed oxygen supply pressures and aqueous solutions with viscosities ranging from 1 to 6.5 cP, which simulated viscosities of commonly used organ preservation solutions. Results and Conclusions: The VOPS produced mean flow rates ranging from 0.6 to 28.2 mL/min and perfusion pressures from 4.8 to 96.8 mmHg, which successfully achieved the desired perfusion parameters for human kidneys. This work provides evidence that the VOPS described herein has the versatility to perfuse organs using many of the clinically available preservation solutions.

29 July 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
AGAlireza Abbasi Ghiri
Alireza Abbasi Ghiri
PMPeace Msengi
Peace Msengi
ACAlba Chocron
Alba Chocron
EREvan Rodriguez
Evan Rodriguez
SBScott Barclay
Scott Barclay
MSMorteza Seidi
Morteza Seidi
Combat helmet padding must attenuate fundamentally different blunt and ballistic impact loading, yet most existing systems are designed primarily for a single regime. This study presents OmniShield, a passive, geometry-driven, pre-curved buckling combat helmet padding designed to exhibit boundary-condition-dependent deformation modes under blunt and ballistic loading conditions. OmniShield was evaluated against commercial foam- and lattice-based padding systems. Helmet-level performance was assessed using a MICH helmet mounted on a Hybrid III 50th percentile head-neck assembly. Ballistic impacts were evaluated using 124-grain-9-mm-FMJ rounds at 1400±50ft/s at front, side, and rear locations, while blunt impacts were assessed using a linear impactor at the same locations and at 10, 14, and 17ft/s. High-speed imaging revealed distinct deformation modes of OmniShield under blunt and ballistic conditions. Under ballistic impacts, OmniShield reduced head peak linear acceleration (PLA) and Head Injury Criterion (HIC) by 20-36% and 46-69%, respectively, relative to foam-based padding, and by up to 21% and 45%, respectively, relative to the lattice padding. Under blunt impacts, OmniShield produced lower or comparable PLA and HIC across velocities and locations. These results demonstrate that geometry-programmed deformation can enable a single helmet padding architecture with effective multi-threat performance beyond conventional material-property-driven designs.